PROBLEM: (89297) (PATCH ID: TCR520-025) ******** This patch fixes a situation where a cluster shutdown under load on a cluster using a LAN interconnect takes a very long time. The problem is that as each cluster member is shut down, there is the potential for a long delay of up to nine minutes. This delay could also potentially occur when a single node goes down. This delay does not affect cluster availablity, only the amount of time it takes for the cluster to fully remove a node from the cluster. PROBLEM: (Backport) (PATCH ID: TCR520-137) ******** On boot, make "duplicate incoming connections" not cause a panic. Provides a better and complete error message in the event of a misconfigured ICS/TCP adapter. PROBLEM: (90463, 93506) (PATCH ID: TCR520-199) ******** This patch fixes a condition where a node is not allowed to join the cluster after a panic. It also addresses a condition where a node may panic while under load. PROBLEM: (95125, SSRT2394) (PATCH ID: TCR520-222) ******** A potential security vulnerability has been discovered that may result in denial of service (DoS) on HP TruCluster Server systems. This potential security vulnerability may be in the form of local and remote security domain risks.