PROBLEM:  (CLD HPAQ5131P)    (Patch ID: OSF440-101)
********
PROBLEM:
This patch fixes a problem in viewing a variable subrange parameter from
a pascal module while using dbx.  While trying to view a particular parameter
type, dbx truncates the address, and gives the error

        "can't read from process (address 0xffff)"  

The following Pascal program is an example that demonstrates the problem.

        PROGRAM dbx_word_err(output);
        TYPE
           word = [WORD] 0..65535;

        VAR
           chn : word;

        PROCEDURE test(VAR chan: word);
        VAR
           blah : word;

        BEGIN

           blah := 5;
           chan := blah + 100;
        END;

        BEGIN
           test(chn);
        END.

The following dbx session illustrates the problem:

        dbx dbx_work_err

        dbx version 3.11.10
        Type 'help' for help.

        DBX_WORD_ERR:  20  test(chn);
        (dbx) stop in test
        [2] stop in TEST
        (dbx) r
        [2] stopped at   [TEST:15 ,0x120001ccc]         blah := 5;
        (dbx) p chan

        can't read from process (address 0xfd00)