SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
security patches support
.
.
.
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
.
photo of jumper
.
.
.
. .

OpenVMS VAXPHV01_071 VAX V7.1 FDDI Drivers ECO Summary

TITLE: OpenVMS VAXPHV01_071 VAX V7.1 FDDI Drivers ECO Summary Modification Date: 22-FEB-99 Modification Type: New Kit NOTE: An OpenVMS saveset or PCSI installation file is stored on the Internet in a self-expanding compressed file. The name of the compressed file will be kit_name-dcx_vaxexe for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha. Once the file is copied to your system, it can be expanded by typing RUN compressed_file. The resultant file will be the OpenVMS saveset or PCSI installation file which can be used to install the ECO. Copyright (c) Compaq Computer Corporation 1999. All rights reserved. OP/SYS: DIGITAL OpenVMS VAX COMPONENT: FDDI Drivers ECDRIVER EFDRIVER EPDRIVER ESDRIVER ETDRIVER EXDRIVER EZDRIVER FCDRIVER FQDRIVER FXDRIVER NET$CSMACD NET$FDDI XEDRIVER XQDRIVER SOURCE: Compaq Computer Corporation ECO INFORMATION: ECO Kit Name: VAXPHV01_071 ECO Kits Superseded by This ECO Kit: None ECO Kit Approximate Size: 1098 Blocks Kit Applies To: OpenVMS VAX V7.1 System/Cluster Reboot Necessary: Yes Rolling Re-boot Supported: Yes Installation Rating: INSTALL_3 3 - To be installed on all systems running the listed versions of OpenVMS which are experiencing the problems described. Kit Dependencies: The following remedial kit(s) must be installed BEFORE installation of this kit: None In order to receive all the corrections listed in this kit, the following remedial kits should also be installed: None ECO KIT SUMMARY: An ECO kit exists for FDDI Drivers on OpenVMS VAX V7.1. This kit addresses the following problems: o For the command: NCL> SHOW FDDI STATION FDDI-0 * ALL the SMTstationID field was displayed as '0000000000000000'H, but should have been '080008002B209E45'H. o A crash occurred in module FX$SCHED_CMDUNS_FORK while doing a DEVICELOCK. The crash occurred under the following conditions: 1. FDDI (DEMFA) 2. MOPRC (60-02) 3. crash address FXDRIVER+022E4 4. current process was running TSM$MAIN o During testing of failover to a second FDDI controller, after an FDDI cable was removed, a SET HOST command hung for one minute, resulting in a bugcheck at TIMER.BUG. Note that the problem did not cause a fatal error and allowed the FDDI ring to resynchronize. o DECnet hung for 1 minute when the FDDI cable was removed from the bulkhead. o Attempting to start the MOPRC protocol on a DEMFA returned an SS$_DEVREQERR error status. o If a DEMFA FDDI controller fails, then transmit requests can possibly fail to complete within a timeout period. The failure that a user sees is that the FDDI path fails and then the cluster software does not switch to another path, usually resulting in a CLUEXIT error. o When the cable is disconnected from the DEMFA FDDI controller, timing problems can occur in the driver, which could result in a crash after an extended period of cable disconnections (typically weeks). o The LAN Driver received a loopback packet with a broadcast destination address, which was an invalid use of the loopback protocol (90-00) format. However, the packet was not regarded as invalid, resulting in a crash at EZDRIVER+072E3. o Transmit timeouts errors must be set as fatal. A problem with failover occurred on the DEMFA on a VAX system. Although a transmit timeout had occurred, the transmit completed with an error status and continued. Since the failure happened in such a way that the link did not go down and come back up, a failover never happened. o A crash occurred during timeout processing and it can happen on a VAX 4000-90, VAX 4000-300, etc., that also has an SGEC Ethernet adapter. INSTALLATION NOTES: The images in this kit will not take effect until the system is rebooted. If there are other nodes in the VMScluster, they must also be rebooted in order to make use of the new image(s). If it is not possible or convenient to reboot the entire cluster at this time, a rolling re-boot may be performed. All trademarks are the property of their respective owners.



This patch can be found at any of these sites:

Colorado Site
Georgia Site
European Site



Files on this server are as follows:

vaxphv01_071.README
vaxphv01_071.CHKSUM
vaxphv01_071.CVRLET_TXT
vaxphv01_071.a-dcx_vaxexe
.
1.800.AT.COMPAQ .

privacy and legal statement