SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
security patches support
.
.
.
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
.
photo of jumper
.
.
.
. .

OpenVMS VMS712_SHADOWING-V0100 Alpha V7.1-2 Shadowing ECO Summary

TITLE: OpenVMS VMS712_SHADOWING-V0100 Alpha V7.1-2 Shadowing ECO Summary Modification Date: 27-JAN-2000 Modification Type: New Kit NOTE: An OpenVMS saveset or PCSI installation file is stored on the Internet in a self-expanding compressed file. The name of the compressed file will be kit_name-dcx_vaxexe for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha. Once the file is copied to your system, it can be expanded by typing RUN compressed_file. The resultant file will be the OpenVMS saveset or PCSI installation file which can be used to install the ECO. Copyright (c) Compaq Computer Corporation 2000. All rights reserved. OP/SYS: OpenVMS Alpha COMPONENT: Volume Shadowing SOURCE: Compaq Computer Corporation ECO INFORMATION: ECO Kit Name: VMS712_SHADOWING-V0100 DEC-AXPVMS-VMS712_SHADOWING-V0100--4.PCSI ECO Kits Superseded by This ECO Kit: None ECO Kit Approximate Size: 2096 Blocks Kit Applies To: OpenVMS Alpha V7.1-2 System/Cluster Reboot Necessary: Yes Rolling Re-boot Supported: Yes Installation Rating: INSTALL_2 2 - To be installed on all systems running the listed version(s) of OpenVMS and using the following feature(s): SHADOWING Kit Dependencies: The following remedial kit(s) must be installed BEFORE installation of this kit: VMS712_UPDATE-V0300 In order to receive all the corrections listed in this kit, the following remedial kits should also be installed: None ECO KIT SUMMARY: An ECO kit exists for Shadowing on OpenVMS Alpha V7.1-2. This kit addresses the following problems: o When a copy operation that interrupts a merge operation is terminating, it finds that there are no members marked for the merge and the thread crashes the system with a SHADDETINCON bug check. Images Affected: - [SYS$LDR]SYS$SHDRIVER.EXE - [SYSEXE]SHADOW_SERVER.EXE o SHOW DEVICES shows zero percent merged status although the shadow set status does not indicate that a merge is required. Images Affected: - [SYS$LDR]SYS$SHDRIVER.EXE - [SYSEXE]SHADOW_SERVER.EXE o Bit 16 in SHADOW_SYS_DISK can be set by the user to eliminate using remote members of the shadowset for reads. Occasionally, use of bit 16 fails to eliminate remote members from being used. Images Affected: - [SYS$LDR]SYS$SHDRIVER.EXE - [SYSEXE]SHADOW_SERVER.EXE o A CPUSPINWAIT bug check can occur if the read of the SCB of a shadow set member cannot pass the checksum test. Images Affected: - [SYS$LDR]SYS$SHDRIVER.EXE - [SYSEXE]SHADOW_SERVER.EXE o DCD (Disk Copy Data) will not always be initiated properly. During an assisted copy operation, if the source member was dismounted or otherwise removed from the shadow set, the connection to the controller would not clean up correctly. Images Affected: - [SYS$LDR]SYS$SHDRIVER.EXE - [SYSEXE]SHADOW_SERVER.EXE o A full copy operation that is interrupted for a mini-merge will not complete the full copy operation correctly. Images Affected: - [SYS$LDR]SYS$SHDRIVER.EXE - [SYSEXE]SHADOW_SERVER.EXE o Typing incorrect commands results in a system crash. Images Affected: - [SYS$LDR]SYS$SHDRIVER.EXE - [SYSEXE]SHADOW_SERVER.EXE o When two disks are added to a shadowset in the same mount command, the copies are done sequentially instead of in parallel. This causes the copies to take twice as long as they should. Images Affected: - [SYS$LDR]SYS$SHDRIVER.EXE - [SYSEXE]SHADOW_SERVER.EXE INSTALLATION NOTES: The images in this kit will not take effect until the system is rebooted. If there are other nodes in the VMScluster, they must also be rebooted in order to make use of the new image(s). If it is not possible or convenient to reboot the entire cluster at this time, a rolling re-boot may be performed. All trademarks are the property of their respective owners.



This patch can be found at any of these sites:

Colorado Site
Georgia Site
European Site



Files on this server are as follows:

dec-axpvms-vms712_shadowing-v0100--4.README
dec-axpvms-vms712_shadowing-v0100--4.CHKSUM
dec-axpvms-vms712_shadowing-v0100--4.pcsi-dcx_axpexe
vms712_shadowing-v0100.CVRLET_TXT
.
1.800.AT.COMPAQ .

privacy and legal statement