OpenVMS VAXBACK01_072 VAX V7.2 Backup Utility ECO Summary
TITLE: OpenVMS VAXBACK01_072 VAX V7.2 Backup Utility ECO Summary
Modification Date: 30-JUL-1999
Modification Type: New Kit
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
The name of the compressed file will be kit_name-dcx_vaxexe
for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
Once the file is copied to your system, it can be expanded
by typing RUN compressed_file. The resultant file will
be the OpenVMS saveset or PCSI installation file which
can be used to install the ECO.
Copyright (c) Compaq Computer Corporation 1999. All rights reserved
OP/SYS: OpenVMS VAX
COMPONENT: Backup Utility
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: VAXBACK01_072
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 504 Blocks
Kit Applies To: OpenVMS VAX V7.2
System/Cluster Reboot Necessary: No
Rolling Re-boot Supported: Not Applicable
Installation Rating: INSTALL_3
3 - To be installed on all systems running
the listed versions of OpenVMS which
are experiencing the problems described.
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for the Backup Utility on OpenVMS VAX V7.2. This
kit addresses the following problems:
o An %BACKUP-F-BADOPTVAL error can occur when using an
Identifier String for a BACKUP/BY_OWNER qualifier value.
For example:
$ BACKUP SOURCE:*.*/BY_OWNER=USER TAPE:A.BCK/SAV
%BACKUP-F-BADOPTVAL, invalid callable interface option value,
argument position 7, option type = 59, option value = 2147549409
Image(s) Affected: [SYSEXE]BACKUP.EXE; [SYSLIB]BACKUPSHR.EXE
o Attempting to use BACKUP/ENCRYPT in BATCH results in the error
%BACKUP-F-ENCNOTSUP.
Images(s) Affected: [SYSEXE]BACKUP.EXE; [SYSLIB]BACKUPSHR.EXE
o The BACKUP/DRIVE_CLASS qualifier was not processed properly.
Images(s) Affected: [SYSEXE]BACKUP.EXE; [SYSLIB]BACKUPSHR.EXE
o BACKUP/JOURNAL fails with an ACCVIO under the following two
conditions:
- backing up a moderate number of files to tape
- backing up a file, where the combined length of the
directory specification and filename exceed 512
characters
Image(s) Affected: [SYSEXE]BACKUP.EXE; [SYSLIB]BACKUPSHR.EXE
INSTALLATION NOTES:
The system does not need to be rebooted after this kit is installed.
However, if the system is a member of a VMScluster, the other cluster
members should be rebooted or this kit should be installed on each
system in order to make use of the new image(s).
All trademarks are the property of their respective owners.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
European Site
Files on this server are as follows:
vaxback01_072.README
vaxback01_072.CHKSUM
vaxback01_072.CVRLET_TXT
vaxback01_072.a-dcx_vaxexe
vaxback01_072.CVRLET_TXT