SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
security patches support
.
.
.
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
.
photo of jumper
.
.
.
. .

*OpenVMS, STORAGE] STRIPEVAXE02021 VAX V5.4 - V6.1 Striping ECO Summary

TITLE: *OpenVMS, STORAGE] STRIPEVAXE02021 VAX V5.4 - V6.1 Striping ECO Summary NOTE: An OpenVMS saveset or PCSI installation file is stored on the Internet in a self-expanding compressed file. The name of the compressed file will be kit_name-dcx_vaxexe for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha. Once the file is copied to your system, it can be expanded by typing RUN compressed_file. The resultant file will be the OpenVMS saveset or PCSI installation file which can be used to install the ECO. Copyright (c) Digital Equipment Corporation 1998. All rights reserved. PRODUCT: POLYCENTER Striping for OpenVMS VAX, Version 2.1 OP/SYS: OpenVMS VAX COMPONENT: Striping Driver (STDRIVER) SOURCE: Digital Equipment Corporation ECO INFORMATION: ECO Kit Name: STRIPEVAXE02021 ECO Kits Superseded by This ECO Kit: STRIPEVAXE01021 ECO Kit Approximate Size: 1897 Blocks Saveset A: 1890 Blocks Kit Applies To: POLYCENTER Striping for OpenVMS VAX V2.1 on OpenVMS VAX V5.4, V5.4-1, V5.4-2, V5.4-3, V5.5, V5.5-1, V5.5-2, V6.0, V6.1 System/Cluster Reboot Necessary: Yes NOTE: The installation kit for this ECO does not contain any executable images. The appropriate image will be generated by the object modules at installation time depending upon the version of OpenVMS VAX to which the kit is applied. ECO KIT SUMMARY: An ECO kit exists for the Striping Driver on OpenVMS VAX V5.4 through V6.1. This kit addresses the following problems: PROBLEMS ADDRESSED IN STRIPEVAXE02021: NOTE: This kit contains a remedial to correct behavior caused by the use of OpenVMS patch kit VAXSHAD09, "shadowing writes past the legal length of an IRP for OpenVMS V6.1 and earlier". In OpenVMS V6.2, OpenVMS expanded the size of the IRP data structure. The VAXSHAD09 patch kit utilizes these values for 6.2 and earlier versions of OpenVMS. o Increase the size of the structure that contain the member IRPs. PROBLEMS ADDRESSED IN STRIPEVAXE01021: o If a BIND fails because a stripeset is already bound, some of the existing stripeset data structures are deallocated. o When a stripeset is initialized using the /FILES_11 qualifier, a signed comparison is made against the 8.5 GB limit. This may cause a stripeset larger that 8.5 GB to be created. o The BIND_UNBIND_LCK descriptor is not locked down. This might cause a PGFIPLHI bugcheck to could occur when binding a stripeset. o Incorrectly clearing the UCB$W_REFC field causes a negative reference count and dangling locks with cleared value blocks for a stripeset device. INSTALLATION NOTES: The system must be rebooted after this kit is installed to make use of the new images. If you have other nodes in your OpenVMS VAXcluster, they must be rebooted or you must install this kit on each system in order to make use of the new images.



This patch can be found at any of these sites:

Colorado Site
Georgia Site
European Site



Files on this server are as follows:

stripevaxe02021.README
stripevaxe02021.CHKSUM
stripevaxe02021.CVRLET_TXT
stripevaxe02021.a-dcx_vaxexe
.
1.800.AT.COMPAQ .

privacy and legal statement