**************************** ECO SUMMARY INFORMATION **************************** Release Date: 22-AUG-2006 Kit Name: DEC-AXPVMS-VMS732_TDF-V0400--4.PCSI$COMPRESSED Kit Applies To: OpenVMS ALPHA V7.3-2 Approximate Kit Size: 249 blocks Installation Rating: INSTALL_3 Reboot Required: No Superseded Kits: VMS732_TDF-V0300 Mandatory Kit Dependencies: VMS732_UPDATE-V0700 or later VMS732_PCSI-V0300 or later Optional Kit Dependencies: None Checksums: VMS732_TDF-V0400.ZIPEXE Checksum: 1797595413 DEC-AXPVMS-VMS732_TDF-V0400--4.PCSI$COMPRESSED Checksum: 4068520043 VMS732_TDF-V0400.ZIPEXE MD5 Checksum: 65A86EAB60E003EA632F331EADF78BFE DEC-AXPVMS-VMS732_TDF-V0400--4.PCSI$COMPRESSED MD5 Checksum: 77130FBFF196C76EE34EE8AEAB67B42A ======================================================================= Hewlett-Packard OpenVMS ECO Cover Letter ======================================================================= 1 KIT NAME: VMS732_TDF-V0400 2 KIT DESCRIPTION: 2.1 Installation Rating: INSTALL_3 : To be installed by customers experiencing the problems corrected. 2.2 Reboot Requirement: No reboot is necessary after installation of this kit. 2.3 Version(s) of OpenVMS to which this kit may be applied: OpenVMS ALPHA V7.3-2 2.4 New functionality or new hardware support provided: No 3 KITS SUPERSEDED BY THIS KIT: - VMS732_TDF-V0300 4 KIT DEPENDENCIES: 4.1 The following remedial kit(s), or later, must be installed BEFORE installation of this, or any required kit: - VMS732_PCSI-V0300 - VMS732_UPDATE-V0700 4.2 In order to receive all the corrections listed in this kit, the following remedial kits, or later, should also be installed: - None Page 2 5 NEW FUNCTIONALITY AND/OR PROBLEMS ADDRESSED IN THE VMS732_TDF-V0400 KIT 5.1 New functionality addressed in this kit Not Applicable 5.2 Problems addressed in this kit 5.2.1 {problem abstract} 5.2.1.1 Problem Description: The following timezone related problems are corrected: o If SYS$MANAGER:UTC$TIME_SETUP.COM is used to change the timezone, for example from EDT to MET, the DTSS$TIMEZONE_DIFFERENTIAL.DAT file retains the TDF value from the EDT timezone. o In addition, if a system using DTSS or DCE DTSS was shutdown after it had adjusted the clock for standard or daylight saving time then the timezone settings could revert back to the previous values after a reboot under certain conditions. These problems do not happen when VMS daylight saving time management, (SYSGEN parameter AUTO_DLIGHT_SAV = 1) is used to adjust the clock. Images Affected: - [SYSEXE]TDF$SET_TIMEZONE.EXE 5.2.1.2 CLDs, and QARs reporting this problem: 5.2.1.2.1 CLD(s) QXCM1000335369,QXCM1000327089 5.2.1.2.2 QAR(s) None. 5.2.1.3 Problem Analysis: TDF values stored in the SYS$TIMEZONE.DAT file are not updated when DecNet DTSS or DCE DTSS adjust the clock values. VMS was restoring the value from the SYS$TIMEZONE.DAT file after the reboot assuming the user has manually adjusted the TDF value. Page 3 5.2.1.4 Release Version of OpenVMS that will contain this change: Next Release after OpenVMS Alpha V8.3 5.2.1.5 Work-arounds: A workaround for the DTSS$TIMEZONE_DIFFERENTIAL.DAT problem is to run SYS$MANAGER:UTC$TIME_SETUP.OM again for MET. The TDF is set correctly in DTSS$TIMEZONE_DIFFERENTIAL.DAT after the second execution. 6 PROBLEMS ADDRESSED IN PREVIOUS KITS Problems addressed by previously released VMS732_TDF ECO kits can be found in the following files: o VMS732_TDF-V100.RELEASE_NOTES o VMS732_TDF-V200.RELEASE_NOTES o VMS732_TDF-V300.RELEASE_NOTES Before kit installation, these files can be extracted from the kit via the following commands: o To extract all release notes files at once use: PRODUCT EXTRACT RELEASE_NOTES VMS732_TDF/VERSION= 4.0 /DESTINATION= destination_directory o To extract a single release notes file use: PRODUCT EXTRACT FILE VMS732_TDF/VERSION= V4.0 - /SELECT=[SYSUPD]release_note_name/DESTINATION=destination_directory 7 FILES PATCHED OR REPLACED: o [SYSEXE]TDF$SET_TIMEZONE.EXE (new image) Image Identification Information image name: "TDF$SET_TIMEZONE" image file identification: "TDF V1.0-0" image file build identification: "0060111004" link date/time: 24-MAY-2006 10:24:53.53 linker identification: "A11-50" Overall Image Checksum: 2170368035 Page 4 8 INSTALLATION INSTRUCTIONS 8.1 Test/Debug Image Loss In the course of debugging problems reported to OpenVMS Engineering, customers may be given debug or point-fix images to install. Typically, these images do not have the same image generation flags contained in images released via the OpenVMS remedial patch process. Because of this, any debug or point-fix image that is in the SYS$COMMON area, will be replaced by any image of the same name installed by this kit. If this occurs, you will lose any functionality that is provided by the replaced image. If you wish to retain these debug or point-fix images, you can take the following steps: o Prior to installing this kit, move the test/debug image(s) to be saved to the SYS$SPECIFIC area. o During kit installation, you will be asked if you wish to delete the image(s) in SYS$SPECIFIC. You should answer NO for each image that you want to keep. o After installation completes, but before rebooting the system (if required), move the image(s) from SYS$SPECIFIC back to SYS$COMMON. 8.2 Compressed File This kit is provided as a DCX compressed kit. To expand this file to the installable .PCSI file, run the file with a RUN file_name command. When the file is run you will see the following output: $ RUN VMS732_TDF-V0400.PCSI-DCX_AXPEXE FTSV DCX auto-extractible compressed file for OpenVMS (AXP) FTSV V3.0 -- FTSV$DCX_AXP_AUTO_EXTRACT Copyright (c) Digital Equipment Corp. 1993 Options: [output_file_specification] [input_file_specification] The decompressor needs to know the filename to use for the decompressed file. If you don't specify any, it will use the original name of the file before it was compressed, and create it in the current directory. If you specify a directory name, the file will be created in that directory. Decompress into (file specification): If you want the file to be expanded into a different directory, enter the directory specification. DO NOT enter a new file name. The expanded file must retain the original name. If you want to expand the file via batch, the command file must contain an answer to the"Decompress into (file specification)" question, either a or an alternate directory specification Page 5 8.3 Installation Command Install this kit with the POLYCENTER Software installation utility by logging into the SYSTEM account, and typing the following at the DCL prompt: PRODUCT INSTALL VMS732_TDF[/SOURCE=location of Kit] Note that this kit will install with the /SAVE_RECOVERY_DATA option turned on. Using this qualifier will allow easy removal of the kit from the system in the event of problems. If you wish to disable this option you must use the /NOSAVE_RECOVERY_DATA qualifier on the PRODUCT INSTALL command. The /SAVE_RECOVERY_DATA qualifier is optional but highly recommended. Using this qualifier will allow easy removal of the kit from the system in the event of problems. The kit location may be a tape drive, CD, or a disk directory that contains the kit. The /SOURCE qualifier is not needed if the PRODUCT INSTALL command is executed from the same directory as the kit location. Additional help on installing PCSI kits can be found by typing HELP PRODUCT INSTALL at the system prompt. 8.4 Scripting of Answers to Installation Questions During installation, this kit will ask and require user response to several questions. If you wish to automate the installation of this kit and avoid having to provide responses to these questions, you must create a DCL command procedure that includes the following logical name definitions and commands: o To avoid the BACKUP question, define the following: $ DEFINE/SYS NO_ASK$BACKUP TRUE o To save replaced files as *.*_OLD define the following logical name as YES. If you do not wish to save replaced files, define the logical name as NO. Note that if you use the /SAVE_RECOVERY_DATA qualifier (recommended) on the PRODUCT INSTALL command all replaced files will be saved as part of that operation. There is no need to also save files as *.*_OLD: $ DEFINE/JOB ARCHIVE_OLD NO o Add the following qualifiers to the PRODUCT INSTALL command and add that command to the DCL procedure. /PROD=DEC/BASE=AXPVMS/VER=V4.0 [/SOURCE=location of Kit] o De-assign the logical names assigned Page 6 For example, a sample command file to install the VMS732_TDF-V0400 kit would be: $ DEFINE/SYS NO_ASK$BACKUP TRUE $ DEFINE/JOB ARCHIVE_OLD NO $! $ PROD INSTALL VMS732_TDF/PRODUCER=DEC/BASE=AXPVMS/VER=V4.0" $! $ DEASSIGN/SYS NO_ASK$BACKUP $! $ exit $! 8.5 Special Installation Instructions: After installing this patch kit, the following commands should be executed to insure proper functioning of your timezone files: 1. DELETE SYS$SYSTEM:dtss$timezone_differential.dat;* 2. DELETE SYS$SYSTEM:sys$timezone_src.dat;*, sys$timezone.dat;* 3. @SYS$MANAGER:UTC$TIME_SETUP [set to your timezone] 9 COPYRIGHT AND DISCLAIMER: (C) Copyright 2006 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP and/or its subsidiaries required for possession, use, or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. Neither HP nor any of its subsidiaries shall be liable for technical or editorial errors or omissions contained herein. The information in this document is provided "as is" without warranty of any kind and is subject to change without notice. The warranties for HP products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty. DISCLAIMER OF WARRANTY AND LIMITATION OF LIABILITY THIS PATCH IS PROVIDED AS IS, WITHOUT WARRANTY OF ANY KIND. ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, OR NON-INFRINGEMENT, ARE HEREBY EXCLUDED TO THE EXTENT PERMITTED BY APPLICABLE LAW. IN NO EVENT WILL HP BE LIABLE FOR ANY LOST REVENUE OR PROFIT, OR FOR SPECIAL, INDIRECT, CONSEQUENTIAL, INCIDENTAL OR PUNITIVE DAMAGES, HOWEVER CAUSED AND REGARDLESS OF THE THEORY OF LIABILITY, WITH RESPECT TO ANY PATCH Page 7 MADE AVAILABLE HERE OR TO THE USE OF SUCH PATCH.