OpenVMS ALPSYS09_070 Alpha V7.0 EXEC_INIT.EXE ECO Summary
|
TITLE: OpenVMS ALPSYS09_070 Alpha V7.0 EXEC_INIT.EXE ECO Summary
Modification Date: 27-AUG-98
Modification Type: DOCUMENTATION: Editorial Modification
Corrected reference from ALPSYS08_070 to
ALPSYS09_070.
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
The name of the compressed file will be kit_name-dcx_vaxexe
for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
Once the file is copied to your system, it can be expanded
by typing RUN compressed_file. The resultant file will
be the OpenVMS saveset or PCSI installation file which
can be used to install the ECO.
Copyright (c) Digital Equipment Corporation 1997. All rights reserved.
PRODUCT: DIGITAL OpenVMS Alpha
COMPONENT: EXEC_INIT.EXE
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: ALPSYS09_070
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 421 Blocks
Kit Applies To: OpenVMS Alpha V7.0
System/Cluster Reboot Necessary: Yes
Installation Rating: 1 - To be installed on all systems running
the listed version(s) of OpenVMS.
NOTE: In order to receive the full fixes listed in this kit,
the following remedial kits also need to be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for EXEC_INIT.EXE on OpenVMS Alpha V7.0. This kit
addresses the following problems:
o Reducing the value of the PHYSICAL_MEMORY sysgen parameter on
an AlphaServer 2100 with console version V4.7 or later may
fail to boot. The failure is a boot crash just after the PFN
database is initialized.
INSTALLATION NOTES:
In order for the corrections in this kit to take effect, the system must
be rebooted. If the system is a member of a VMScluster, the entire
cluster should be rebooted.
Files on this server are as follows:
|
»alpsys09_070.README
»alpsys09_070.CHKSUM
»alpsys09_070.CVRLET_TXT
»alpsys09_070.a-dcx_axpexe
|