Content starts here
HP Services Software Patches - alpprts02_070
 
NOTE:  An OpenVMS saveset or PCSI installation file is stored
       on the Internet in a self-expanding compressed file.
       The name of the compressed file will be kit_name-dcx_vaxexe
       for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
 
       Once the file is copied to your system, it can be expanded
       by typing RUN compressed_file.  The resultant file will
       be the OpenVMS saveset or PCSI installation file which
       can be used to install the ECO.
 
*OpenVMS] ALPPRTS02_070 Alpha V6.1-V7.0 Print Symbiont ECO Summary
 
Copyright (c) Digital Equipment Corporation 1995, 1996.  All rights reserved.

OP/SYS:     OpenVMS Alpha

COMPONENT:  Print Symbiont 
              PRTSMB.EXE 
              SMBSRVSHR.EXE

SOURCE:     Digital Equipment Corporation

ECO INFORMATION:

     ECO Kit Name:  ALPPRTS02_070
     ECO Kits Superseded by This ECO Kit:  ALPPRTS01_070
                                           ALPPRTS01_062
                                           AXPPRTS02_061 (AXPPRTS)
                                           AXPJOBC01_061 (CSCPAT_2087 V1.2)
                                             This kit was never released.
                                           AXPQMAN01_061 (CSCPAT_2087 V1.1)
                                           AXPPRTS01_061 (CSCPAT_2087 V1.0)
     ECO Kit Approximate Size:  1426 Blocks
                                Saveset A -  198 Blocks
                                Saveset B -  414 Blocks
                                Saveset C -  396 Blocks
                                Saveset D -  396 Blocks
                             Cover Letter -   22 Blocks

     Kit Applies To:  OpenVMS Alpha V6.1, V6.1-1H1, V6.1-1H2, 
                                    V6.2, V6.2-1H1, V6.2-1H2, V6.2-1H3
                                    V7.0
     System/Cluster Reboot Necessary:  Yes
     Installation Rating:  3 - To be installed on all systems running
                               the listed versions of OpenVMS which
                               are experiencing the problems described.

     NOTE:  In order to receive the full fixes listed in this kit,
            the following remedial kits also need to be installed:

                 None.


ECO KIT SUMMARY:

An ECO kit exists for the Print Symbiont on OpenVMS Alpha V6.1 through 
V7.0.  This kit addresses the following problems:

Problems Addressed in the ALPPRTS02_070 Kit for OpenVMS Alpha V6.1,
  V6.1-1H1, V6.1-1H2, V6.2, V6.2-1H1, V6.2-1H2, V6.2-1H3, and V7.0:

  o  A file which contains a form feed code at the end of the
     record prints in unexpected format.  The format of the
     following page is destroyed.

  o  User modified symbionts using the LAT protocol and a user work
     area terminate with %SYSTEM-F-ABORT when a print job is
     queued.

  o  On OpenVMS Version 7.0 or higher, printing a VFC file on
     either PRTSYM or LATSYM, gives an invalid prefix control
     character, even though the prefix control character is a valid
     "C0" control character.

     On OpenVMS Version 6.2 or lower, when printing a VFC file on
     either PRTSYM or LATSYM, the process goes into 100% CPU
     utilization.


Problems Addressed in the ALPPRTS01_070 Kit for OpenVMS Alpha V6.1,
  V6.1-1H1, V6.1-1H2, V6.2, V6.2-1H1, V6.2-1H2:

  o  Use of the /DISABLE_AUTOSTART option in the SYSMAN SHUTDOWN
     NODE command results in an infinite loop.

  o  Users with READALL priv, who do not otherwise have read access
     to a file, cannot successfully print the file.  However, 
     they are able to copy or type the same file.

  o  When a print request encounters a security violation on an
     input file at the time of printing, the symbiont does not
     close the file.  The symbiont signals the following error
     but the input file is not closed:

          Job X (queue COLA, entry 3) terminated with error status
             %PSM-E-OPENIN, error opening !AS as input

Problems Addressed in ALPPRTS01_070 for OpenVMS Alpha V6.1,
   V6.1-1H1, V6.2, V6.2-1H1, V6.2-1H2, V7.0:

  o  Symbiont processes may die with insufficient dynamic memory.
     The problem has been observed under the following scenarios:

     +  Restarting a large print job to begin printing at a
        specific page.  For example:

          $ PRINT/PAGE=(90000,90001) A_BIG_PRINTOUT.LIS

     +  UCX$TELNET symbiont process managing 16 queues with lots
        of print activity.

     +  Batch/Print high speed test symbionts running with 16-32
        queues.

          When the symbiont process dies the following message is
          broadcast to the operator console and written to the
          OPERATOR.LOG file.

            %%%%%%%%%%%  OPCOM  22-FEB-1996 08:08:14.18  %%%%%%%%%%%
            $!Message from user QUEUE_MANAGE on QMUNGR
            $!%QMAN-E-SYMDEL, unexpected symbiont process termination

            $!%%%%%%%%%%%  OPCOM  22-FEB-1996 08:08:14.18 %%%%%%%%%%%
            $!Message from user QUEUE_MANAGE on QMUNGR
            $!-SYSTEM-F-INSFMEM, insufficient dynamic memory


NOTE:  According to OpenVMS Engineering, the fixes discussed 
       below have been included in OpenVMS Alpha V7.0.
       There are some fixes that have been included in previous
       versions of OpenVMS and those versions are specified in
       text following the problem descriptions.

Problems Addressed in the ALPPRTS01_062 Kit for OpenVMS Alpha V6.1,
V6.1-1H1, V6.1-1H2, V6.2:

  o  LATSYM loops infinitely on queues with RESET modules that do form
     feeds.  The common symptoms are:

       -  Queue printing a file forever
       -  Queue stuck in starting state
       -  STOP/QUEUE fails to pause queue
       -  LATSYM symbiont processes looping

  o  Files printed to a LN03 device are corrupted, usually with the
     first page margins incorrect.

Problems addressed in the AXPPRTS02_061 kit:

  o  The unreleased AXPJOBC01_061 kit contained both QMAN and
     PRTSMB ECOs.  It superseded both AXPQMAN01_061 and
     AXPPRTS01_061.  This kit, AXPPRTS02_061, only replaces the
     the print symbiont and SMBSRVSHR fixes from that combined
     kit.  The QMAN fixes have been moved to the AXPQMAN03_061
     ECO kit.


Problems addressed in the AXPQMAN01_061 kit:

  o  If a queue is set up with a form other than the default form,
     and a job is printed using PAGE_SETUP,  the printer will
     continually spew out paper with only the output from the page
     setup module.  This continues until the entry is deleted from
     the queue.

  o  The 'START/QUEUE/SEARCH="text_string"' DCL command does not start
     the print job on the correct page.  When a paused print queue is
     restarted with the 'START/QUEUE/SEARCH="text_string"' command, the
     print job is not restarted on the page that contains the search
     text.  Rather, the print job starts a few lines prior to the actual
     page containing the text.

     With the use of the 'START/QUEUE/BACKWARD=n' DCL command, the
     print symbiont does not set the first record flag.  This causes
     an extra line feed to occur which offsets the page alignment
     by one line.

  o  PRTSMB or a user-modified symbiont can fail with an ACCVIO with
     the PC=1A45 in the Librarian routines.  This causes the print job
     to hang.

  o  In the following cases, the print symbiont prints an unwanted
     form feed after a print job:

          + Output ends exactly at the end of the page

          + File printed with /PASSALL ends with a form feed

  o  When printing a file with the /FORM qualifier on a LAT printer,
     it is possible for the LATSYM to crash with PSM-F-BADLOGIC,
     internal logic error.  This was shown with a file that contained
     an OSC escape sequence and had a WIDTH of 255.

  o  When a paused or stopped queue, which was printing a FORTRAN
     carriage control file, is restarted with the /TOP_OF_FILE
     qualifier, extraneous formatting characters may be sent to
     the printer device.

  o  When a modified print symbiont contains a combination of a
     user written input routine and a user written format routine,
     memory leaks occur in the modified print symbiont.

  o  A WPS-formatted file may leave the symbiont in a state where
     printing a non-WPS file directly afterwards will cause the
     vertical margins on the first page to be incorrect.  This only
     happens if a top margin is defined for the non-WPS file's form
     and no flag page is produced between jobs.

  o  After a 'START/QUEUE' command is issued and the printing of a
     FORTRAN CC file is resumed, a symbiont may crash producing a
     .DMP file

  o  With latest print symbiont, ALL-IN-1 users may experience a
     blank page between each job

Problems addressed in the AXPPRTS01_061 kit:

  o  When starting a LAT queue, the symbiont process may crash and
     the queue will be left in a stopped state.  A process
     dump, SYS$SYSTEM:LATSYM.DMP, will be created.


INSTALLATION NOTES:

In order for the corrections in this kit to take effect, the system
must be rebooted.  If the system is a member of a VMScluster,
the entire cluster should be rebooted.
Files on this server are as follows:
»alpprts02_070.README
»alpprts02_070.CHKSUM
»alpprts02_070.CVRLET_TXT
»alpprts02_070.a-dcx_axpexe
»alpprts02_070.b-dcx_axpexe
»alpprts02_070.c-dcx_axpexe
»alpprts02_070.d-dcx_axpexe
privacy statement using this site means you accept its terms