;---------------------------------------- ; NOTE: ; Windows NT version 4.0 and later include support for ; modems through the Universal Modem Driver (Unimodem) using TAPI. ; Thus, if you are installing a new unsupported modem, you should ; obtain a modem driver from the modem manufacturer. ; RAS continues to support modems for older legacy systems. ; To configure a previously installed unsupported modem to work with RAS, ; add an entry for that modem in this file. ; ; Modem responses are normally located in the global [Responses] ; section. Most modems will return one of the responses listed in the ; global [Responses] section. If you encounter a modem with a different ; response sequence than any of the responses already listed, add that ; new sequence to the global [Respones] section. You may also put new ; modem response sequences immediately following the command section of ; a specific modem. Such responses are checked before the global ; responses. ; ; Individual modems will have separate command sections. Modems with ; identical command sequences can be aliased. E.g., if modem 2 has the ; same command sequences as modem 1, then modem 2's section might be ; as follows: ; ; [modem 2] ; alias=modem 1 ; ; Aliases to aliased sections are not allowed. In other words, in the ; example given above, if you have "modem 3" which also has an identical ; command sequence to modem 1 and modem 2, you can alias modem 3 to ; modem 1, but you cannot alias modem 3 to modem 2. ;---------------------------------------- [Responses] ;---------------------------------------- ;OK, ERROR, NO DIALTONE, NO CARRIER, etc ;---------------------------------------- OK=OK OK=OK OK=OK OK=OK LOOP=RING LOOP=RING LOOP=RRING LOOP=RINGING LOOP=DIALING ERROR=ERROR ERROR=ABORTED ERROR_NO_CARRIER=NO CARRIER ERROR_VOICE=VOICE ERROR_NO_DIALTONE=NO DIALTONE ERROR_NO_DIALTONE=NO DIAL TONE ERROR_BUSY=BUSY ERROR_NO_ANSWER=NO ANSWER ERROR_NO_PROMPTTONE=NO PROMPTTONE ;PDI modem ERROR=ERROR DATA Button not defined ;---------------------------------------- ;CONNECT responses with APPEND macro come first to force proper match ;---------------------------------------- ;Zoom V32bis modem CONNECT_EC=\ CARRIER \ PROTOCOL: LAPM\ CONNECT ;ATI modems, Hayes V Series; Practical CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M/HDX\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42bis\ CONNECT CONNECT_EC=\ CARRIER V.34\ PROTOCOL: LAP-M\ COMPRESSION: V.42bis\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M/HDX\ COMPRESSION: MNP5\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: MNP5\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M/HDX\ COMPRESSION: MNP4\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: MNP4\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT /ARQ CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M/HDX\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ CONNECT ;Stray char (0xFF) appears from time to time. CONNECT=\ CARRIER \ PROTOCOL: NONE\ CONNECT CONNECT=\ CARRIER \ PROTOCOL: NONE\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: MNP\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: MNP\ COMPRESSION: CLASS 5\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: MNP\ COMPRESSION: MNP5\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: MNP\ COMPRESSION: NONE\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: V.42BIS\ CONNECT ;Next connect response occasionally occurs on Practical Peripherals 9600SA CONNECT=\ CARRIER \ PROTOCOL: NONE\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: V.42/LAPM\ COMPRESSION: NONE\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAPM\ COMPRESSION: NONE\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: V.42/LAPM\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: V.42/LAPM\ COMPRESSION: CLASS 5\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: V.42/LAPM\ COMPRESSION: NONE\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ COMPRESSION: CLASS 5\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ COMPRESSION: NONE\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ CONNECT CONNECT=\ CARRIER \ PROTOCOL: NONE\ CONNECT CONNECT=\ CARRIER \ PROTOCOL: NONE\ COMPRESSION: NONE\ CONNECT ;megahertz pcmcia responses CONNECT_EC=\ CARRIER V.34\ PROTOCOL: NONE\ COMPRESSION: NONE\ CONNECT CONNECT_EC=\ CARRIER V.34\ PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT CONNECT_EC=\ CARRIER V.34\ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=\ CARRIER V.34\ PROTOCOL: LAP-M\ COMPRESSION: V.42bis\ CONNECT ;---------------------------------------- ;CONNECT responses that do not use the APPEND macro ;---------------------------------------- CONNECT=CONNECT ;AT&T ARK DM 424 CONNECT_EC=CONNECT EC ;AT&T Dataports like an extra space CONNECT=CONNECT CONNECT=CONNECT ;Telebits CONNECT=CONNECT / CONNECT_EC=CONNECT /LAPM CONNECT_EC=CONNECT /LAPM/ CONNECT_EC=CONNECT /LAPM/COMP/ CONNECT_EC=CONNECT /REL/COMP/ CONNECT_EC=CONNECT /REL/ ;;Digicom Scout CONNECT=CONNECT CONNECT=\ CONNECT CONNECT=PLEASE SET TO CONNECT=\ PROTOCOL: NONE\ CONNECT CONNECT=CONNECT FAST ;Racal RMD CONNECT_EC=CONNECT MNP CONNECT_EC=CONNECT V.42 CONNECT_EC=CONNECT V.42 bis CONNECT_EC=CONNECT V.42bis ;UDS Motorola CONNECT_EC=\ CONNECT /REL CONNECT_EC=\ CONNECT /LAPM ;USRobotics modems CONNECT=CONNECT /NONE CONNECT_EC=CONNECT /ARQ ;Codex 3261Fast returns this if *XC1 ;Codex 2264 also returns this CONNECT_EC=CONNECT RELIABLE CONNECT=CONNECT /V32/NONE ;;ATIs use this string CONNECT_EC=CONNECT /LAP-M CONNECT_EC=CONNECT /LAP-M OK CONNECT_EC=CONNECT /LAPM/COMP ;ZyXel U-1496 CONNECT_EC=CONNECT /V32b /MNP5 CONNECT_EC=CONNECT /V32b /MNP4 CONNECT_EC=CONNECT /V32b /MNP3 CONNECT_EC=CONNECT /V32b /V42b CONNECT_EC=CONNECT /V32b /V42 CONNECT=CONNECT /V32b /NONE CONNECT_EC=CONNECT /V.32 T/MNP5 CONNECT_EC=CONNECT /V.32 T/MNP4 CONNECT_EC=CONNECT /V.32 T/MNP3 CONNECT_EC=CONNECT /V.32 T/V42b CONNECT_EC=CONNECT /V.32 T/V42 CONNECT=CONNECT /V.32 T/NONE CONNECT_EC=CONNECT /V.22b /MNP5 CONNECT_EC=CONNECT /V.22b /MNP4 CONNECT_EC=CONNECT /V.22b /MNP3 CONNECT_EC=CONNECT /V.22b /V42b CONNECT_EC=CONNECT /V.22b /V42 CONNECT=CONNECT /V.22b /NONE CONNECT_EC=CONNECT /ZyX /MNP5/SREJ CONNECT_EC=CONNECT /ZyX /MNP4/SREJ CONNECT_EC=CONNECT /ZyX /MNP3/SREJ CONNECT_EC=CONNECT /ZyX /V42b/SREJ CONNECT_EC=CONNECT /ZyX /V42/SREJ CONNECT_EC=CONNECT /V32b /MNP5/SREJ CONNECT_EC=CONNECT /V32b /MNP4/SREJ CONNECT_EC=CONNECT /V32b /MNP3/SREJ CONNECT_EC=CONNECT /V32b /V42b/SREJ CONNECT_EC=CONNECT /V32b /V42/SREJ CONNECT_EC=CONNECT /ZyX /V42B/SREJ CONNECT=CONNECT /V32b /NONE CONNECT_EC=CONNECT /V.32 T/MNP5/SREJ CONNECT_EC=CONNECT /V.32 T/MNP4/SREJ CONNECT_EC=CONNECT /V.32 T/MNP3/SREJ CONNECT_EC=CONNECT /V.32 T/V42b/SREJ CONNECT_EC=CONNECT /V.32 T/V42/SREJ CONNECT=CONNECT /V.32 T/NONE CONNECT_EC=CONNECT /V.22b /MNP5/SREJ CONNECT_EC=CONNECT /V.22b /MNP4/SREJ CONNECT_EC=CONNECT /V.22b /MNP3/SREJ CONNECT_EC=CONNECT /V.22b /V42b/SREJ CONNECT_EC=CONNECT /V.22b /V42/SREJ CONNECT=CONNECT /V.22b /NONE ;NEC modems CONNECT_EC=\ CARRIER \ CONNECT /V.42bis CONNECT_EC=\ CARRIER \ CONNECT /V.42 CONNECT=\ CARRIER \ CONNECT CONNECT_EC=\ CARRIER \ CONNECT /REC CONNECT_EC=\ CARRIER \ CONNECT /REL ;Supra CONNECT=\ CARRIER \ OK\ OK\ CONNECT ;Texas Instruments Internal CONNECT_EC=CONNECT /REL CONNECT_EC=CONNECT /REL MNP CONNECT_EC=CONNECT /REL V.42 CONNECT_EC=CONNECT /V.42 ;Rockwell CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ COMPRESSION: V.42BIS\ CONNECT ;---------------------------------------- ; Additional Responses for German Modems ;---------------------------------------- ;Creatix LCxxx CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /REL CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: CLASS5\ CONNECT /REL CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT /REL CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ COMPRESSION: V.42BIS\ CONNECT /REL CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ COMPRESSION: CLASS5\ CONNECT /REL CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ COMPRESSION: NONE\ CONNECT /REL CONNECT_EC=\ CARRIER \ PROTOCOL: ALT-CELLULAR\ COMPRESSION: V.42BIS\ CONNECT /REL CONNECT_EC=\ CARRIER \ PROTOCOL: ALT-CELLULAR\ COMPRESSION: CLASS5\ CONNECT /REL CONNECT_EC=\ CARRIER \ PROTOCOL: ALT-CELLULAR\ COMPRESSION: NONE\ CONNECT /REL ; ZyXEL (german and austrian versions) ; ZyXEL CELLULAR MODES ; ; ATTENTION: 1 OR 2 spaces before required CONNECT_EC=CONNECT /CELL /V42b/SREJ CONNECT_EC=CONNECT /CELL /V42 /SREJ CONNECT_EC=CONNECT /CELL /V42b CONNECT_EC=CONNECT /CELL /V42 CONNECT_EC=CONNECT /CELL /MNP5 CONNECT_EC=CONNECT /CELL /MNP4 CONNECT=CONNECT /CELL /NONE CONNECT_EC=CONNECT /CELL /V42b/SREJ CONNECT_EC=CONNECT /CELL /V42 /SREJ CONNECT_EC=CONNECT /CELL /V42b CONNECT_EC=CONNECT /CELL /V42 CONNECT_EC=CONNECT /CELL /MNP5 CONNECT_EC=CONNECT /CELL /MNP4 CONNECT=CONNECT /CELL /NONE CONNECT_EC=CONNECT /CELL T/V42b/SREJ CONNECT_EC=CONNECT /CELL T/V42 /SREJ CONNECT_EC=CONNECT /CELL T/V42b CONNECT_EC=CONNECT /CELL T/V42 CONNECT_EC=CONNECT /CELL T/MNP5 CONNECT_EC=CONNECT /CELL T/MNP4 CONNECT=CONNECT /CELL T/NONE CONNECT_EC=CONNECT /CELL C/V42b/SREJ CONNECT_EC=CONNECT /CELL C/V42 /SREJ CONNECT_EC=CONNECT /CELL C/V42b CONNECT_EC=CONNECT /CELL C/V42 CONNECT_EC=CONNECT /CELL C/MNP5 CONNECT_EC=CONNECT /CELL C/MNP4 CONNECT=CONNECT /CELL C/NONE ; Centraleurope ZyXEL PROPRIETARY MODES CONNECT_EC=CONNECT /ZyX /V42b/SREJ CONNECT_EC=CONNECT /ZyX /V42 /SREJ CONNECT_EC=CONNECT /ZyX /V42b CONNECT_EC=CONNECT /ZyX /V42 CONNECT_EC=CONNECT /ZyX /MNP5 CONNECT_EC=CONNECT /ZyX /MNP4 CONNECT=CONNECT /ZyX /NONE CONNECT_EC=CONNECT /ZyX /V42b/SREJ CONNECT_EC=CONNECT /ZyX /V42 /SREJ CONNECT_EC=CONNECT /ZyX /V42b CONNECT_EC=CONNECT /ZyX /V42 CONNECT_EC=CONNECT /ZyX /MNP5 CONNECT_EC=CONNECT /ZyX /MNP4 CONNECT=CONNECT /ZyX /NONE ; ZYXEL - STANDARD MODES (additional responses to US versions) CONNECT_EC=CONNECT /V32b /V42b/SREJ CONNECT_EC=CONNECT /V32b /V42 /SREJ CONNECT_EC=CONNECT /V32b /V42b/SREJ CONNECT_EC=CONNECT /V32b /V42 /SREJ CONNECT_EC=CONNECT /V32b /V42b CONNECT_EC=CONNECT /V32b /V42 CONNECT_EC=CONNECT /V32b /MNP5 CONNECT_EC=CONNECT /V32b /MNP4 CONNECT=CONNECT /V32b /NONE CONNECT_EC=CONNECT /V.32 T/V42b/SREJ CONNECT_EC=CONNECT /V.32 T/V42 /SREJ CONNECT_EC=CONNECT /V.32 /V42b/SREJ CONNECT_EC=CONNECT /V.32 /V42 /SREJ CONNECT_EC=CONNECT /V.32 /V42b CONNECT_EC=CONNECT /V.32 /V42 CONNECT_EC=CONNECT /V.32 /MNP5 CONNECT_EC=CONNECT /V.32 /MNP4 CONNECT=CONNECT /V.32 /NONE CONNECT_EC=CONNECT /V.22b /V42b/SREJ CONNECT_EC=CONNECT /V.22b /V42 /SREJ CONNECT_EC=CONNECT /V.22 /V42b/SREJ CONNECT_EC=CONNECT /V.22 /V42 /SREJ CONNECT_EC=CONNECT /V.22 /V42b CONNECT_EC=CONNECT /V.22 /V42 CONNECT_EC=CONNECT /V.22 /MNP5 CONNECT_EC=CONNECT /V.22 /MNP4 CONNECT=CONNECT /V.22 /NONE ;the next section attempts to catch all other responses not ;explicitly listed above. The port speed is not changed ;from what it was originally set to by RAS. CONNECT_EC=\ CARRIER ;---------------------------------------- [Angia DataStart for CompaqLTE] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=19200 =M1 =M0 =&K3 =&K0 =&U1 =&U0 =\\N7 =\\N0 =ATDT =ATX3D DETECT_STRING=ATI3 DETECT_RESPONSE=ANGIA Corporation COMMAND_INIT=AT&F&C1&D2 L3 V1 W2 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /REL5 CONNECT_EC=CONNECT /REL4 COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /REL5 CONNECT_EC=CONNECT /REL4 ;---------------------------------------- [Apex Data PCMCIA 144] ALIAS=Megahertz XJack PCMCIA 144 DETECT_STRING=ATI3 DETECT_RESPONSE=APEX DATA INC. V.32bis ;---------------------------------------- [ATI 2400 etc/e] =M1 =M0 =&K3 =&K0 =&U1 =&U0 =&Q6 =&Q0 =ATDT =AT X3 D CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=9600 DETECT_STRING=ATI3 DETECT_RESPONSE=2400etc/e COMMAND_INIT=AT&F&C1&D2 X4 W1 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [ATI 9600 etc/e] =M1 =M0 =&K3 =&K0 ;=&U1 ;compression forced off for stability =&U0 =&U0 =&Q6 =&Q0 =ATDT =AT X3 D CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 DETECT_STRING=ATI0 DETECT_RESPONSE=960 COMMAND_INIT=AT&F&C1&D2 W1 X4 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [AT&T 2224 CEO] =M1 =M0 =\\Q3 =\\Q0 =\\N3 =\\N0 =ATDT =AT X3 D CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 COMMAND_INIT=AT&F&C1&D2 V1 X4 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 COMMAND_DIAL= ;---------------------------------------- [AT&T Comsphere 3810] ALIAS=AT&T Comsphere 3820 DETECT_STRING=ATI4 DETECT_RESPONSE=3810 ;---------------------------------------- [AT&T Comsphere 3811] ALIAS=AT&T Comsphere 3820 DETECT_STRING=ATI4 DETECT_RESPONSE=3811 ;---------------------------------------- [AT&T Comsphere 3820] =M1 =M0 =\\Q3 =\\Q0 =%C1"H3 =%C0"H0 =\\N5 =\\N0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 DETECT_STRING=ATI4 DETECT_RESPONSE=3820 COMMAND_INIT=AT&F&C1&D2 V1 X7 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 COMMAND_DIAL= ;---------------------------------------- [AT&T Comsphere 3810 Plus 288] =M1 =M0 =\\Q3 =\\Q0 =%C1"H3 =%C0"H0 =\\N5 =\\N0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=28800 MAXCONNECTBPS=57600 DETECT_STRING=ATI4 DETECT_RESPONSE=3980-A1-401 COMMAND_INIT=AT&F&C1&D2 V1 X7 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 COMMAND_DIAL= ;---------------------------------------- [AT&T Comsphere 3830] ALIAS=AT&T Comsphere 3820 DETECT_STRING=ATI4 DETECT_RESPONSE=3830 ;---------------------------------------- [AT&T Dataport] =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N5 =\\N0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 DETECT_STRING=ATI4 DETECT_RESPONSE=3710 DETECT_RESPONSE=3721 COMMAND_INIT=AT&F&C1&D2 V1 X7 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 COMMAND_DIAL= ;---------------------------------------- [AT&T Dataport Express] =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N7 =\\N0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 DETECT_STRING=ATI1 DETECT_RESPONSE=FW Level 091394 COMMAND_INIT=AT&F&C1&D2 V1 X7 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 COMMAND_DIAL= ;---------------------------------------- [AT&T Dataport 288] =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N7 =\\N0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=28800 MAXCONNECTBPS=57600 DETECT_STRING=ATI1 DETECT_RESPONSE=FW Level 030695 COMMAND_INIT=AT&F&C1&D2 V1 X7 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 COMMAND_DIAL= ;---------------------------------------- [AT&T Paradyne PCMCIA] ALIAS=AT&T Dataport DETECT_STRING=ATI7 DETECT_RESPONSE=Credit Card DETECT_RESPONSE=CREDIT CARD ;---------------------------------------- [AT&T KeepInTouch Express PCMCIA] ALIAS=AT&T Dataport DETECT_STRING=ATI7 DETECT_RESPONSE=Credit Card DETECT_RESPONSE=CREDIT CARD ;---------------------------------------- [AT&T 4024] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 =M1 =M0 =ATDT =ATD DETECT_STRING=ATI0 DETECT_RESPONSE=24 COMMAND_INIT=ATE1Q0V1X4Y0S0=0 S7=15 &D2&C1&M0 COMMAND_LISTEN=ATS0=2 COMMAND_DIAL= ;---------------------------------------- [Bocamodem M1440 Alt] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =M1 =M0 =&K3 =&K0 ;use both %C and appropriate S46 settings to work correctly =%C1S46=138 =%C0S46=136 =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=TR14 COMMAND_INIT=AT&F&C1&D2&R1Q0V1E1X4 S0=0 S7=55 S2=128 ;to get short responses ;COMMAND_INIT=ATW0S95=0 ;to get long responses COMMAND_INIT=ATW1S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 [Boca Modem V.Fast Class] ALIAS=Hayes Optima 28800 DETECT_STRING=ATI3 DETECT_RESPONSE=VFC DETECT_STRING=ATI DETECT_RESPONSE=28800 ;---------------------------------------- [Cardinal 2400e] ALIAS=Hayes Compatible 2400 DETECT_STRING=ATI0 DETECT_RESPONSE=249 DETECT_RESPONSE=248 DETECT_RESPONSE=242 ;---------------------------------------- [Cardinal 9600] =M1 =M0 =&H1&I1 =&H0&I0 =&M6 =&M4 =&M4 =&M0&B0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=19200 DETECT_STRING=ATI0 DETECT_RESPONSE=9600 DETECT_RESPONSE=AT&T V.32bis COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Cardinal 14400] =M1 =M0 =&K3 =&K0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Cardinal 14400 Internal] ;Compression turned off for stability. ;Maximum DTE speed set to 19200 =M1 =M0 =&K3 =&K0 =%C0 =%C0 =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=V1. TR14 DETECT_RESPONSE=U8 DETECT_STRING=ATI0 DETECT_RESPONSE=144 DETECT_RESPONSE=AT&T V.32 CALLBACKTIME=10 DEFAULTOFF=compression protocol hwflowcontrol CLIENTDEFAULTOFF=compression protocol hwflowcontrol MAXCARRIERBPS=19200 MAXCONNECTBPS=19200 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Codex 2264] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 =M1 =M0 =*FL3 =*FL0 =*SM3 =*SM0 =*SM2 =*SM0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2S0=0 V1 *XC1 E1 S7=55 S2=128 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Codex 3220] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 =*FL0 =*FL3 =*SM0 =*SM3 =*DC0 =*DC1 =M0 =M1 =ATDT =ATD DETECT_STRING=AT&I0 DETECT_RESPONSE=7040 COMMAND_INIT=AT&F&C1&D2 V1 X4 *XC1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Codex 3260] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 =*FL0 =*FL3 =*SM0 =*SM3 =*DC0 =*DC1 =M0 =M1 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 V1 *XC1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Codex 3261] ALIAS=Codex 3260 DETECT_STRING=AT&I0 DETECT_RESPONSE=6510 ;---------------------------------------- [Codex 3262] ALIAS=Codex 3260 ;---------------------------------------- [Codex 3263] ALIAS=Codex 3260 ;---------------------------------------- [Codex 3265] ALIAS=Codex 3260 ;---------------------------------------- [Codex 3260 Fast] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 =*FL0 =*FL3 =*SM0 =*SM3 =*DC0 =*DC1 =M0 =M1 =ATDT =ATD COMMAND_INIT=AT&F S0=0 &C1 &D2 V1 X4 S2=128 *XC1 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Codex 3261 Fast] ALIAS=Codex 3260 Fast DETECT_STRING=AT&I0 DETECT_RESPONSE=7061 ;---------------------------------------- [Codex 3262 Fast] ALIAS=Codex 3260 Fast ;---------------------------------------- [Codex 3263 Fast] ALIAS=Codex 3260 Fast ;---------------------------------------- [Codex 3265 Fast] ALIAS=Codex 3260 Fast ;---------------------------------------- [Codex V.34R] ALIAS=Codex 3260 Fast ;---------------------------------------- [Codex 3220 Plus] ;ALIAS=Codex 3220 CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 =*FL0 =*FL3 =*SM0 =*SM3 =*DC0 =*DC1 =M0 =M1 =ATDT =AT X3 D COMMAND_INIT=AT&F&C1&D2 V1 X4 *XC1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Compaq 2400 PCMCIA] ALIAS=Hayes Compatible 2400 DETECT_STRING=ATI9 DETECT_RESPONSE=iNC215US ;---------------------------------------- [Compaq SpeedPAQ 144] =M1 =M0 =\\Q3 =\\Q0 =\\N3 =\\N0 =%C1 =%C0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 DETECT_STRING=ATI9 DETECT_RESPONSE=COMPAQ COMMAND_INIT=AT&F&C1&D2 V1 W2S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT ;---------------------------------------- [Compaq SpeedPAQ 144 PCMCIA] ALIAS=Compaq SpeedPAQ 144 DETECT_STRING=ATI9 DETECT_RESPONSE=COMPAQ ;-------------------------------------------------------------------------------- ; WARNING: The following modem had problems with CALLBACK feature in RAS. ;-------------------------------------------------------------------------------- [CXR Telcom 1445] =M1 =M0 =*LR2*LG2 =*LR0*LG0 =*M2 =*M1 =*E1 =*E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 DETECT_STRING=ATI3 DETECT_RESPONSE=1445 COMMAND_INIT=AT&F1 COMMAND_INIT=AT&C1&D2 *V1 *N1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP5 COMMAND_LISTEN=ATS0=1 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP5 ;---------------------------------------- [DataRace RediModem V.32bis] ;Error control and flow control forced on for stability. =M1 =M0 =\\Q3 =\\Q3 =\\N3 =\\N3 =%C1 =%C0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 DETECT_STRING=ATI3 DETECT_RESPONSE=PC Half-Card V.32bis/V.42bis/Fax COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 W1 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Datatrek 2424AMH] =M1 =M0 =\\Q3 =\\Q0 =\\N3 =\\N0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT=CONNECT ;---------------------------------------- [Datatrek Elite 624D] ;Advanced features disabled =M1 =M0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 DETECT_STRING=ATI4 DETECT_RESPONSE=DataTrek . D32 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 ;COMMAND_INIT=AT-M0\\V0 COMMAND_INIT=AT-M0\\V0 COMMAND_INIT=AT%C0 COMMAND_DIAL= CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT ;---------------------------------------- [Datatrek V.32] ;Supported as a client modem only =M1 =M0 =\\Q3 =\\Q0 =\\N3 =\\N0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 DETECT_STRING=ATI4 DETECT_RESPONSE=DataTrek . PR COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT-M0 \\V0 COMMAND_DIAL= CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT ;---------------------------------------- [DP Defender 1000D Hayes Ultra] ;This entry uses the Digital Pathways Defender 1000D with the ;Hayes Ultra 9600 modem. ;The macro definitions, =, and COMMAND_INIT= lines must be ;changed in order to use other modems with the Defender. ;Set Defender ports to fixed 19200 bps (not autobaud). ;Set Originate Fallback to OFF on Configure DAD Options screen. ;(If used with Telebit WorldBlazer set S51=5 to fix port speed at 19200.) DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=19200 CALLBACK_TIME=10 =&K0 =&K3 =&Q0 =&Q5 =S46=136 =S46=2 =M0 =M1 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 V1 X4 S0=0 S2=128 S7=55 W1 S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATE0Q1S0=2 LOOP= LOOP= CONNECT="DIALIN_GATEWAY" CONNECT= CONNECT= CONNECT= ;---------------------------------------- [Digicom Scout] =M1 =M0 =*F3 =*F0 =*E9 = =*E5 =*E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 DETECT_STRING=AT*O DETECT_RESPONSE=SCOUT COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT*M0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Digicom Scout Plus] =M1 =M0 =*F3 =*F0 =*E9 = =*E5 =*E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 DETECT_STRING=ATI0 DETECT_RESPONSE=961 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT*M0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [DSI 9624LE Plus] =M1 =M0 =*F3 =*F0 =*E9 = =*E5 =*E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 DETECT_STRING=AT*O DETECT_RESPONSE=9624LEP COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55*M0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [DSI 9624E] =M1 =M0 =*F3 =*F0 =*E9 = =*E5 =*E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=19200 DETECT_STRING=AT*O DETECT_RESPONSE=MODEL: 9624E COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT*M0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Eiger 144 PCMCIA] ALIAS=Megahertz XJack PCMCIA 144 DETECT_STRING=ATI6 DETECT_RESPONSE=RC144DPL ;---------------------------------------- [ETech UFOMATE P1496MX] =M1 =M0 =$F4 =$F5 =$C1 =$C0 =$E3 =$E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 DETECT_STRING=ATI1 DETECT_RESPONSE=P1496MX COMMAND_INIT=AT&F&C1&D2 $X1 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Evercom 24] ALIAS=Hayes Compatible 2400 DETECT_STRING=ATI4 DETECT_RESPONSE=EV943 ;---------------------------------------- [Evercom 24E] =M1 =M0 =ATDT =ATX3D DETECT_STRING=ATI4 DETECT_RESPONSE=EV947 CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 COMMAND_INIT=ATZ&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Evercom 24E+] =M1 =M0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 COMMAND_INIT=AT&F &C1 &D2 Q0 V1 \N1 S0=0 S2=128 S7=55 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;----------------------------------------------- ; Fastcomm Communications MonoFRAD ; (Frame Relay Access Device) ; ; The MonoFRAD has no modem command language. ; Thus, RAS can't query the device to recognize ; it automatically. ; ; To use this device, configure the RAS port, ; cancel the automatic configuration, and then ; select this entry from the listbox. ; ;----------------------------------------------- [Fastcomm MonoFRAD] CALLBACK_TIME=10 DEFAULTOFF=compression MAXCARRIERBPS=57600 MAXCONNECTBPS=115200 COMMAND_INIT= NoResponse COMMAND_LISTEN= NoResponse COMMAND_DIAL= NoResponse ;---------------------------------------- [Gateway 2000 Internal Alt] ALIAS=US Robotics Sportster 14400 ;----------------------------------------- [Gateway 2000 Internal] =&K0 =&K3 =\\N0 =\\N3 =%C0 =%C1 =M0 =M1 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 DETECT_STRING=ATI3 DETECT_RESPONSE=Gateway TelePath 1.5 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 W1 S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Gateway 2000 Nomad 14400] =\\Q0 =\\Q3 =\\N0 =\\N7 =%C0 =%C1 =M0 =M1 =ATDT =ATX1D DETECT_STRING=ATI3 DETECT_RESPONSE=Texas Instrument V.32 CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 COMMAND_INIT=AT&F&C1&D2 V1 X4 S0=0 S2=128 S7=55 W0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Gateway 2000 PCMCIA] ALIAS=Megahertz XJack PCMCIA 144 DETECT_STRING=ATI4 DETECT_RESPONSE=GATEWAY2000 DETECT_STRING=ATI6 DETECT_RESPONSE=RC144DPL ;---------------------------------------- [Generic 144 PCMCIA modem] ALIAS=Megahertz XJack PCMCIA 144 DETECT_STRING=ATI6 DETECT_RESPONSE=RC144DPL ;---------------------------------------- [GVC SM2400] ALIAS=Hayes Compatible 2400 DETECT_STRING=ATI0 DETECT_RESPONSE=249 DETECT_STRING=ATI3 DETECT_RESPONSE=AT-C2401-0E ;---------------------------------------- [GVC SM96] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N6 =\\N0 =ATDT =ATD DETECT_STRING=ATI4 DETECT_RESPONSE=SM-96 COMMAND_INIT=AT&F&C1&D2Q0V1E1S0=0S2=128S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP/COMPRESSED CONNECT_EC=CONNECT /MNP COMPRESSED CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP/COMPRESSED CONNECT_EC=CONNECT /MNP COMPRESSED CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP/COMPRESSED CONNECT_EC=CONNECT /MNP COMPRESSED CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP/COMPRESSED CONNECT_EC=CONNECT /MNP COMPRESSED CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS ;---------------------------------------- [GVC FM14400] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N6 =\\N0 =ATDT =ATD DETECT_STRING=ATI4 DETECT_RESPONSE=FM-144VBIS DETECT_RESPONSE=FM-1114V COMMAND_INIT=AT&F&C1&D2Q0V1E1S0=0S2=128 S7=55 S95=44 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP/COMPRESSED CONNECT_EC=CONNECT /MNP COMPRESSED CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP/COMPRESSED CONNECT_EC=CONNECT /MNP COMPRESSED CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS ;---------------------------------------- [Hayes Accura 14400] ALIAS=Hayes Optima 14400 DETECT_STRING=ATI0 DETECT_RESPONSE=14400 ;---------------------------------------- [Hayes Accura 28800] ALIAS=Hayes Optima 28800 DETECT_STRING=ATI0 DETECT_RESPONSE=28800 ;---------------------------------------- [Hayes Compatible 1200] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=1200 MAXCONNECTBPS=1200 =M1 =M0 =ATDT =ATX3D COMMAND_INIT=ATQ0V1E1S0=0S2=128 S7=55 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Hayes Compatible 2400] =M1 =M0 =ATDT =ATX3D CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 ;DETECT_STRING=ATI ;DETECT_RESPONSE=249 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Hayes Compatible 9600] =M1 =M0 =ATDT =ATX3D CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Hayes Compatible 14400] ALIAS=Hayes Optima 14400 DETECT_STRING=ATI0 DETECT_RESPONSE=14400 ;---------------------------------------- [Hayes Pocket Modem 2400] ALIAS=Hayes Compatible 2400 ;DETECT_STRING=ATI0 ;DETECT_RESPONSE=249 ;---------------------------------------- [Hayes Smartmodem 2400] ALIAS=Hayes Compatible 2400 DETECT_STRING=ATI0 DETECT_RESPONSE=249 DETECT_STRING=ATI3 DETECT_RESPONSE=04-000 ;---------------------------------------- [Hayes Smartmodem 9600] ALIAS=Hayes Compatible 9600 DETECT_STRING=ATI0 DETECT_RESPONSE=960 ;---------------------------------------- [Hayes Optima 9600] =&K0 =&K3 =&Q0 =&Q5 =S46=136 =S46=2 =M0 =M1 =ATDT =ATX3D CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 DETECT_STRING=ATI0 DETECT_RESPONSE=960 COMMAND_INIT=AT&F&C1&D2 V1 X4 S0=0 S2=128 S7=55 W1 S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Hayes Optima 14400] =&K0 =&K3 =&Q0 =&Q5 =S46=136 =S46=2 =M0 =M1 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 DETECT_STRING=ATI0 DETECT_RESPONSE=14400 COMMAND_INIT=AT&F&C1&D2 V1 X4 S0=0 S2=128 S7=55 W1 S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Hayes Optima PCMCIA 14400] ALIAS=Hayes Optima 14400 DETECT_STRING=ATI4 DETECT_RESPONSE=PCMCIA DETECT_STRING=ATI6 DETECT_RESPONSE=RC144DPL ;---------------------------------------- [Hayes Optima 28800] =&K0 =&K3 =&Q0 =&Q5 =S46=136 =S46=2 =M0 =M1 =ATDT =ATD CALLBACKTIME=15 DEFAULTOFF=compression MAXCARRIERBPS=28800 MAXCONNECTBPS=57600 DETECT_STRING=ATI DETECT_RESPONSE=28800 COMMAND_INIT=AT&F&C1&D2 V1 X4 S0=0 S2=128 S7=55 W0 S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Hayes Ultra 9600] ALIAS=Hayes Optima 9600 DETECT_STRING=ATI0 DETECT_RESPONSE=960 ;---------------------------------------- [Hayes Ultra 14400] ALIAS=Hayes Optima 14400 DETECT_STRING=ATI0 DETECT_RESPONSE=14400 ;---------------------------------------- [Hayes V Series Smartmodem 9600] =&K0 =&K3 =&Q0 =&Q5 =S46=0 =S46=2 =M0 =M1 =ATDT =AT X3 D CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=19200 DETECT_STRING=ATI0 DETECT_RESPONSE=960 ;Reset modem COMMAND_INIT=AT&/3 OK= COMMAND_INIT=AT&\\3 OK= COMMAND_INIT=AT&F&W COMMAND_INIT=AT&F&C1&D2 X4 V1 W1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [IBM 14400 PCMCIA] ALIAS=Megahertz XJack PCMCIA 144 DETECT_STRING=ATI3 DETECT_RESPONSE=PCMCIA DETECT_STRING=ATI6 DETECT_RESPONSE=RCV144DPL DETECT_STRING=ATI6 DETECT_RESPONSE=RC144DPL ;---------------------------------------- [Infotel 1414VQE External] ALIAS=Hayes Optima 14400 DETECT_STRING=ATI0 DETECT_RESPONSE=14400 ;---------------------------------------- [Intel SatisFaxtion 100] ALIAS=Hayes Compatible 2400 DETECT_STRING=ATI3 DETECT_RESPONSE=AF-C ;---------------------------------------- [Intel SatisFaxtion 400e] =M1 =M0 =\\Q3 =\\Q0 =%C1"H3 =%C0"H0 =\\N3 =\\N0 =ATDT =AT X3 D CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 DETECT_STRING=ATI3 DETECT_RESPONSE=U20 DETECT_RESPONSE=U21 COMMAND_INIT=AT&F&C1&D2 V1 \\V3 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 COMMAND_DIAL= ;---------------------------------------- [Intel 9600EX] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 =M1 =M0 =\\Q3 =\\Q0 =%C1"H3 =\\N3 =\\N0 =ATDT =ATX3D DETECT_STRING=ATI0 DETECT_RESPONSE=969 DETECT_STRING=ATI3 DETECT_RESPONSE=U21 COMMAND_INIT=AT&F&C1&D2V1S0=0 X4 \\V2 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL CONNECT_EC=CONNECT /REL-LAPM CONNECT_EC=CONNECT /REL-MNP CONNECT_EC=CONNECT /REL-LAPM-COMP CONNECT_EC=CONNECT /REL-MNP-COMP COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL CONNECT_EC=CONNECT /REL-LAPM CONNECT_EC=CONNECT /REL-MNP CONNECT_EC=CONNECT /REL-LAPM-COMP CONNECT_EC=CONNECT /REL-MNP-COMP ;---------------------------------------- [Intel 14400EX] ALIAS=Intel SatisFaxtion 400e DETECT_STRING=ATI3 DETECT_RESPONSE=U20 DETECT_RESPONSE=U21 DETECT_STRING=ATI4 DETECT_RESPONSE=INTEL 14400E ;---------------------------------------- [Intel 14400 PCMCIA] ALIAS=Megahertz XJack PCMCIA 144 DETECT_STRING=ATI3 DETECT_RESPONSE=144 DETECT_STRING=ATI6 DETECT_RESPONSE=RC144DPL ;---------------------------------------- [Kingston DataRex PCMCIA 144] ALIAS=Megahertz XJack PCMCIA 144 DETECT_STRING=ATI4 DETECT_RESPONSE=PCMCIA DETECT_STRING=ATI6 DETECT_RESPONSE=RC144DPL ;---------------------------------------- [Macronix Maxlite Fax 9696] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 =M1 =M0 =&K3 =&K0 =%C1%M3 =%C0 =&Q5 =&Q0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=MAXFAX MAXLITE COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Macronix VOMAX 2000] ALIAS=Hayes Compatible 2400 DETECT_STRING=ATI3 DETECT_RESPONSE=VOMAX 2.1 ;---------------------------------------- [Megahertz P2144 AA Batteries] ALIAS=Megahertz T3144 for Toshiba ;---------------------------------------- [Megahertz P296FMV AA Batteries] ALIAS=Megahertz T396FM for Toshiba ;---------------------------------------- [Megahertz P2144 Pkt Faxmodem] ;strings for rockwell chip modem DEVICETYPE=modem CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =&Q5 =&Q0 =\\N5 =\\N0 =%C1 =%C0 =ATDT =ATD DETECT_STRING=ATI6 DETECT_RESPONSE=144DPL+FAX COMMAND_INIT=AT&F&C1&D2 W2\\G0\\J0 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL ;---------------------------------------- [Megahertz T3144 for Toshiba] DEVICETYPE=modem CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =\\Q3 =\\Q0 =\\N7 =\\N0 =%C1 =%C0 =ATDT =ATX3D COMMAND_INIT=AT&F&C1&D2 W2\\G0\\J0\\V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL ;---------------------------------------- [Megahertz T396FM for Toshiba] DEVICETYPE=modem CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=19200 =M1 =M0 =\\Q3 =\\Q0 =\\N7 =\\N0 =%C1 =%C0 =ATDT =ATX3D COMMAND_INIT=AT&F&C1&D2 W2\\G0\\J0\\V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL ;---------------------------------------- [Megahertz C596FM for CompaqLTE] ALIAS=Megahertz T396FM for Toshiba ;---------------------------------------- [Megahertz Z396FM for Zenith] ALIAS=Megahertz T396FM for Toshiba ;---------------------------------------- [Megahertz Z3144 for Zenith] ALIAS=Megahertz T3144 for Toshiba DETECT_STRING=AT%V DETECT_RESPONSE=AT&T V.32bis/V.42bis/FAX 14400 ;---------------------------------------- [Megahertz C5144 for Compaq LTE] ALIAS=Megahertz T3144 for Toshiba DETECT_STRING=AT%V DETECT_RESPONSE=AT&T V.32bis/V.42bis/FAX 14400 ;---------------------------------------- [Megahertz Alternative] ; use this section if you get Error 651 when ; using [Megahertz P2144] section above. ALIAS=Hayes Optima 14400 ;---------------------------------------- [Megahertz XJack PCMCIA 144] DEVICETYPE=modem CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 =M1 =M0 =&K3 =&K0 =\\N3 =\\N0 =%C3 =%C0 =ATDT =ATX3D DETECT_STRING=ATI4 DETECT_RESPONSE=MEGAHERTZ DETECT_STRING=ATI6 DETECT_RESPONSE=RC144DPL COMMAND_INIT=AT&F&C1&D2 L2 X4 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Megahertz XJack PCMCIA 288] DEVICETYPE=modem CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=28800 MAXCONNECTBPS=57600 =M1 =M0 =&K3 =&K0 =\\N3 =\\N0 =%C1 =%C0 =ATDT =ATX3D DETECT_STRING=ATI4 DETECT_RESPONSE=MEGAHERTZ DETECT_STRING=ATI DETECT_RESPONSE=MHZ AT&T V.34 COMMAND_INIT=AT&F&C1&D2 L2 W0 X4 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Metricom Wireless 9600] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 COMMAND_INIT=AT&F&C1&D2 S0=0 S2=127 S7=55 COMMAND_DIAL=ATDT COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [MicroCom DeskPorte FAST] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=28800 MAXCONNECTBPS=57600 =M1 =M0 =\\N3 =\\N0 =\\Q3 =\\Q0 =%C3 =%C0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=DeskPorte V.FC COMMAND_INIT=AT&F&C1&D2 V1 -M0 W1 S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 COMMAND_DIAL= ;---------------------------------------- [MicroCom DeskPorte FAST ES28.8] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=28800 MAXCONNECTBPS=57600 =M1 =M0 =\\N3 =\\N0 =&K3 =&K0 =%C3 =%C0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=VFC DETECT_STRING=ATI DETECT_RESPONSE=28800 COMMAND_INIT=AT&F&C1&D2 V1 M0 W1 S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 COMMAND_DIAL= ;---------------------------------------- [MicroCom DeskPorte V.34] ALIAS=MicroCom DeskPorte FAST DETECT_STRING=ATI3 DETECT_RESPONSE=DeskPorte 28.8 ;---------------------------------------- [MicroCom TravelCard 288 PCMCIA] ALIAS=MicroCom DeskPorte FAST DETECT_STRING=ATI3 DETECT_RESPONSE=TravelCard V.FC ;---------------------------------------- [MicroCom QX 4232bis] ;Advanced features disabled, MAXCONNECT set to 19200 CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=19200 =M1 =M0 =\\N3 =\\N0 =\\Q3 =\\Q0 =%C3 =%C0 =ATDT =ATD DETECT_STRING=ATI0 DETECT_RESPONSE=1441 DETECT_RESPONSE=1442 COMMAND_INIT=AT&F&C1&D2 W1 V1 \\V1 \\N0 \\Q0 \\J1 %C0 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 ;CONNECT=CONNECT ;CONNECT_EC=CONNECT /REL COMMAND_DIAL= ;CONNECT=CONNECT ;CONNECT_EC=CONNECT /REL ;---------------------------------------- [MicroComQX 4232HS] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 =M1 =M0 =\\N3 =\\N0 =\\Q3 =\\Q0 =%C3 =%C0 =ATDT =ATD DETECT_STRING=ATI0 DETECT_RESPONSE=962 COMMAND_INIT=AT&F&C1&D2 V1 \\V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL ;---------------------------------------- [MicroGate MG96] ;Error control and flow control forced on for stability. CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 =M1 =M0 =&K3 =&K3 =&Q5 =&Q5 =%C1 =%C0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=TR14 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 w1 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT ;---------------------------------------- [MicroGate MG144] ;Error control and flow control forced on for stability. CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =M1 =M0 =&K3 =&K3 =&Q5 =&Q5 =%C1 =%C0 =ATDT =ATD DETECT_STRING=ATI0 DETECT_RESPONSE=14400 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 w1 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT ;---------------------------------------- [MicroPorte 1042] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=9600 =M1 =M0 =\\Q3 =\\Q0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=AT%V DETECT_RESPONSE=MicroPorte COMMAND_INIT=AT&F&C1&D2 V1 \\V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL ;--------------------------- [Modem Blaster 144 PCMCIA] ALIAS=New Media 144 PCMCIA DETECT_STRING=ATI3 DETECT_RESPONSE=CL-MD1414AT ;---------------------------------------- [Motorola Power 288] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=28800 MAXCONNECTBPS=57600 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N7 =\\N0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=Motorola Power 28.8 COMMAND_INIT=AT&F COMMAND_INIT=AT&C1&D2 \\V1 S0=0 S2=128 S7=30 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;------------------------------------------- [MultiTech MultiModem 224] ;Hardware flow control hardcoded ON for stability. =M1 =M0 =&E4 =&E4 =&E15 =&E14 =&E1 =&E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=19200 DETECT_STRING=ATI2 DETECT_RESPONSE=MT224 COMMAND_INIT=AT&F E1 &C1 COMMAND_INIT=AT V1 &D2 &Q1 X4 S0=0 S2=128 S7=55 $BA0 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT RELIABLE CONNECT_EC=CONNECT LAPM CONNECT_EC=CONNECT RELIABLE COMPRESSED CONNECT_EC=CONNECT LAPM COMPRESSED COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT RELIABLE CONNECT_EC=CONNECT LAPM CONNECT_EC=CONNECT RELIABLE COMPRESSED CONNECT_EC=CONNECT LAPM COMPRESSED ;------------------------------------------- [MultiTech MultiModem MT932] =M1 =M0 =&E4 =&E3 =&E15 =&E14 =&E1 =&E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 DETECT_STRING=ATI2 DETECT_RESPONSE=MT932BA COMMAND_INIT=AT&SF1&S0&W COMMAND_INIT=AT E1 COMMAND_INIT=AT &F &C1 V1 &D2 &Q0 X4 &S0 S0=0 S2=128 S7=55 $BA0 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT RELIABLE CONNECT_EC=CONNECT LAPM CONNECT_EC=CONNECT RELIABLE COMPRESSED CONNECT_EC=CONNECT LAPM COMPRESSED COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT RELIABLE CONNECT_EC=CONNECT LAPM CONNECT_EC=CONNECT RELIABLE COMPRESSED CONNECT_EC=CONNECT LAPM COMPRESSED ;------------------------------------------- [MultiTech MultiModem MT1432] =M1 =M0 =&E4 =&E3 =&E15 =&E14 =&E1 =&E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 DETECT_STRING=ATI2 DETECT_RESPONSE=MT1432ZDX COMMAND_INIT=AT&SF1&S0&W COMMAND_INIT=AT E1 COMMAND_INIT=AT &F &C1 V1 &D2 &Q0 X4 &S0 S0=0 S2=128 S7=55 $BA0 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT RELIABLE CONNECT_EC=CONNECT LAPM CONNECT_EC=CONNECT RELIABLE COMPRESSED CONNECT_EC=CONNECT LAPM COMPRESSED COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT RELIABLE CONNECT_EC=CONNECT LAPM CONNECT_EC=CONNECT RELIABLE COMPRESSED CONNECT_EC=CONNECT LAPM COMPRESSED ;------------------------------------------- [MultiTech MultiModem MT2834] =M1 =M0 =&E4 =&E3 =&E15 =&E14 =&E1 =&E0 =ATDT =ATD CALLBACKTIME=15 DEFAULTOFF=compression MAXCARRIERBPS=28800 MAXCONNECTBPS=57600 DETECT_STRING=ATI DETECT_RESPONSE=247 DETECT_STRING=ATI2 DETECT_RESPONSE=MT2834BA COMMAND_INIT=AT&SF1&S0&W COMMAND_INIT=AT E1 COMMAND_INIT=AT &F &C1 V1 &D2 &Q0 X4 &S0 S0=0 S2=128 S7=55 $BA0 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT RELIABLE CONNECT_EC=CONNECT LAPM CONNECT_EC=CONNECT RELIABLE COMPRESSED CONNECT_EC=CONNECT LAPM COMPRESSED COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT RELIABLE CONNECT_EC=CONNECT LAPM CONNECT_EC=CONNECT RELIABLE COMPRESSED CONNECT_EC=CONNECT LAPM COMPRESSED ;---------------------------------------- [NEC 9635E Plus] =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N6 =\\N0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 DETECT_STRING=ATI3 DETECT_RESPONSE=N9635E/PLUS COMMAND_INIT=AT&F&C1&D2 \\V3 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;--------------------------- [NEC 14.4 Data/Fax PCMCIA] ALIAS=AT&T Dataport ;---------------------------------------- [New Media 144 PCMCIA] =M1 =M0 =ATDT =ATX3D CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 DETECT_STRING=ATI3 DETECT_RESPONSE=CL-MD1414AT COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [NoteWorthy 14400 PCMCIA] ALIAS=Megahertz XJack PCMCIA 144 DETECT_STRING=ATI3 DETECT_RESPONSE=144 DETECT_STRING=ATI6 DETECT_RESPONSE=RC144DPL ;---------------------------------------- [Null Modem 4800] CALLBACK_TIME=10 DEFAULTOFF=compression MAXCARRIERBPS=4800 MAXCONNECTBPS=4800 COMMAND_INIT= NoResponse COMMAND_LISTEN= CONNECT=CLIENT CONNECT=CLIENT COMMAND_LISTEN=CLIENTSERVER NoResponse COMMAND_DIAL=CLIENT CONNECT=SERVER ;---------------------------------------- [Null Modem 9600] CALLBACK_TIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 COMMAND_INIT= NoResponse COMMAND_LISTEN= CONNECT=CLIENT CONNECT=CLIENT COMMAND_LISTEN=CLIENTSERVER NoResponse COMMAND_DIAL=CLIENT CONNECT=SERVER ;---------------------------------------- [Null Modem 19200] CALLBACK_TIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=19200 COMMAND_INIT= NoResponse COMMAND_LISTEN= CONNECT=CLIENT CONNECT=CLIENT COMMAND_LISTEN=CLIENTSERVER NoResponse COMMAND_DIAL=CLIENT CONNECT=SERVER ;---------------------------------------- [Null Modem 38400] CALLBACK_TIME=10 DEFAULTOFF=compression MAXCARRIERBPS=38400 MAXCONNECTBPS=38400 COMMAND_INIT= NoResponse COMMAND_LISTEN= CONNECT=CLIENT CONNECT=CLIENT COMMAND_LISTEN=CLIENTSERVER NoResponse COMMAND_DIAL=CLIENT CONNECT=SERVER ;---------------------------------------- [Octocom 8324] ;Hardware flow control and error correction are set ON for stability. =&K3 =&K0 =&E0 =&E1 =*E0 =*E1 =M0 =M1 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=9600 DETECT_STRING=ATI3 DETECT_RESPONSE=317 COMMAND_INIT=AT&F &C3 &D2 &I2 V1 E1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT_EC=CONNECT /LAP-M ACTIVE COMMAND_LISTEN=ATS0=1 CONNECT_EC=CONNECT /LAP-M ACTIVE ;---------------------------------------- [Octocom 8396] =&K3 =&K0 =&E0 =&E1 =*E0 =*E1 =M0 =M1 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 DETECT_STRING=ATI3 DETECT_RESPONSE=321 COMMAND_INIT=AT&F &C3 &D2 &I2 V1 E1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT_EC=CONNECT /LAP-M ACTIVE COMMAND_LISTEN=ATS0=1 CONNECT_EC=CONNECT /LAP-M ACTIVE ;---------------------------------------- [PDI-1000] ;Supported on client side only. =M1 =M0 =&K3 =&K0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 COMMAND_INIT=AT&F&C1&D2 V1 E1 S0=0 S2=128 S7=55 S32=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Practical Peripherals2400 Pkt] ALIAS=Hayes Compatible 2400 DETECT_STRING=ATI3 DETECT_RESPONSE=PM2400PPM ;---------------------------------------- [Practical Peripherals 2400SA] ;Server:Does not hang up normally. Not supported as a server modem. ;Client side works =M1 =M0 =ATDT =ATX3DT CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 DETECT_STRING=ATI3 DETECT_RESPONSE=04-00027-16 DETECT_RESPONSE=AT-C2401-0E COMMAND_INIT=AT&F&D2 V1 S0=0 S2=128 S7=55 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Practical Peripherals 2400MNP] ;Advanced features are disabled. =M1 =M0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 DETECT_STRING=ATI3 DETECT_RESPONSE=04-000 COMMAND_INIT=AT&F&C2&D2 V1 S0=0 S2=128 S7=55 &Q0 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;-------------------------------------------------------------------------------- ; WARNING: The following modem had problems with CALLBACK feature in RAS. ;-------------------------------------------------------------------------------- [Practical Peripherals 9600SA] =&K0 &Q0 =&K3 =&Q6 =&Q5 =S46=136 =S46=138 =M0 =M1 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 DETECT_STRING=ATI3 DETECT_RESPONSE=PM9600 COMMAND_INIT=AT&F&D2&C1 V1 S0=0 S2=128 S7=55 S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Practical Peripherals 9600FX] ALIAS=Practical Peripherals 9600SA DETECT_STRING=ATI3 DETECT_RESPONSE=PM9600FX ;---------------------------------------- [Practical Peripherals 14400SA] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =&K0 &Q0 =&K3 =&Q6 =&Q5 =S46=0 =S46=2 =M0 =M1 =ATDT =AT X3 DT DETECT_STRING=ATI3 DETECT_RESPONSE=PM14400FXSA COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Practical Peripherals 14400FX] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =&K0 =&K3 =&Q0 =&Q5 =S46=0 =S46=2 =M0 =M1 =ATDT =AT X3 DT DETECT_STRING=ATI3 DETECT_RESPONSE=PM14400FX COMMAND_INIT=AT&F&C1&D2 V1 W1 S0=0 S2=128 S7=55 S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Practical Peripherals 14400MT] ALIAS=Practical Peripherals 14400FX DETECT_STRING=ATI3 DETECT_RESPONSE=PM14400FXMT ;---------------------------------------- [Practical Peripherals PC288MT] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=28800 MAXCONNECTBPS=57600 =&K0 =&K3 =&Q0 =&Q5 =S46=0 =S46=2 =M0 =M1 =ATDT =AT X3 DT DETECT_STRING=ATI3 DETECT_RESPONSE=PC288MT COMMAND_INIT=AT&F&C1&D2 V1 W1 S0=0 S2=128 S7=55 S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Practical Peripherals PM288PKT] ALIAS=Practical Peripherals PC288MT DETECT_STRING=ATI3 DETECT_RESPONSE=PM288PPM ;---------------------------------------- [Practical Peripherals PC288SA] ALIAS=Practical Peripherals PC288MT DETECT_STRING=ATI DETECT_RESPONSE=28800 DETECT_STRING=ATI3 DETECT_RESPONSE=PC288SA ;---------------------------------------- [Practical ProClass 144 PCMCIA] ALIAS=Hayes Optima 14400 DETECT_STRING=ATI3 DETECT_RESPONSE=PC144T2 DETECT_STRING=ATI6 DETECT_RESPONSE=PC144T2Statistics ;---------------------------------------- [Racal GSM w/ Hayes Ultra] ;This entry uses the Racal GuardData Gateway Security Module with the ;Hayes Ultra 9600 modem. ;The macro definitions, =, and COMMAND_INIT= lines must be ;changed in order to use other modems with the GSM. ;Do not give callback permission to accounts used with the GSM. ;Set GSM ports to fixed 19200 bps (not autobaud). DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=19200 =&K0 =&K3 =&Q0 =&Q5 =S46=136 =S46=2 =M0 =M1 COMMAND_INIT=AT&F&C1&D2 V1 X4 S0=0 S2=128 S7=55 W1 S95=44 COMMAND_INIT=AT COMMAND_LISTEN=ATE0Q1S0=1 LOOP= CONNECT="DIALIN_GATEWAY" CONNECT= CONNECT= CONNECT= ;---------------------------------------- [Racal RMD 2412] CALLBACKTIME=10 DEFAULTOFF=compression MAXCONNECTBPS=9600 MAXCARRIERBPS=2400 =M1 =M0 =*F2 =*F0 =*D0 =*D1 =*E1 =*E0 =ATDT =AT X3DT COMMAND_INIT=AT&F&C1&D2 X4 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT ;---------------------------------------- [Racal RMD 2422] ALIAS=Racal RMD 2412 DETECT_STRING=ATI0 DETECT_RESPONSE=246 ;---------------------------------------- [Racal RMD 2412/2] Toggled MAXCONNECTBPS back to 2400 CALLBACKTIME=10 DEFAULTOFF=compression MAXCONNECTBPS=2400 MAXCARRIERBPS=2400 =M1 =M0 =*F2 =*F0 =*D0 =*D1 =*E1 =*E0 =ATDT =ATD DETECT_STRING=ATI0 DETECT_RESPONSE=247 COMMAND_INIT=AT&F&C1&D2 X4 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT ;---------------------------------------- [Racal RMD 3221] ;Set MAXCONNECTBPS to disable unsupported baud rate of 12000 bps. CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 =M1 =M0 =*F2 =*F0 =*D1 =*D0 =*E1 =*E0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=RACAL COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Racal RMD 3222] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 =M1 =M0 =\\Q1 =\\Q0 =\\M0 =\\M1\\C4 =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=ATI0 DETECT_RESPONSE=096 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT_EC=\ CONNECT \ V42bis CONNECT=\ CONNECT \ BUFFER CONNECT_EC=\ CONNECT \ V42 CONNECT_EC=\ CONNECT \ MNP CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT_EC=\ CONNECT \ V42bis CONNECT=\ CONNECT \ BUFFER CONNECT_EC=\ CONNECT \ V42 CONNECT_EC=\ CONNECT \ MNP CONNECT=CONNECT ;---------------------------------------- [Racal RMD 3226] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=14400 =M1 =M0 =&K3 =&K3 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=ATI4 DETECT_RESPONSE=3226 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT_EC=\ CONNECT \ V42bis CONNECT=\ CONNECT \ BUFFER CONNECT_EC=\ CONNECT \ V42 CONNECT_EC=\ CONNECT \ MNP CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT_EC=\ CONNECT \ V42bis CONNECT=\ CONNECT \ BUFFER CONNECT_EC=\ CONNECT \ V42 CONNECT_EC=\ CONNECT \ MNP CONNECT=CONNECT ;---------------------------------------- [Racal ALM 3226] ALIAS=Racal RMD 3226 DETECT_STRING=ATI4 DETECT_RESPONSE=3226 ;---------------------------------------- [Racal RMD 3223] ALIAS=Racal RMD 3222 DETECT_STRING=ATI0 DETECT_RESPONSE=960 ;---------------------------------------- [Racal RMD 9632PA] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 =M1 =M0 =\\Q1 =\\Q0 =\\C5 =\\C4 =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=RACAL COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT_EC=\ CONNECT \ MNP CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT_EC=\ CONNECT \ MNP CONNECT=CONNECT ;---------------------------------------- [Racal RMD 9642PA] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=19200 =M1 =M0 =\\Q1 =\\Q0 =\\C5 =\\C4 =\\N3 =\\N0 =ATDT =ATX3 DETECT_STRING=ATI0 DETECT_RESPONSE=096 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT ;Following line disables error correction, compression. To enable, delete ;the following line and use rasphone interface. COMMAND_INIT=AT \\N0 COMMAND_DIAL= CONNECT_EC=\ CONNECT \ MNP CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT_EC=\ CONNECT \ MNP CONNECT=CONNECT ;---------------------------------------- [SD ACM400 w/ AT&T 3820] ;This entry uses the Security Dynamics ACM/400 with the ;AT&T Comsphere 3820 modem. ;The macro definitions, =, and COMMAND_INIT= lines must be ;changed in order to use other modems with the ACM/400. ;Set ACM/400 ports to fixed 19200 bps (not autobaud). ;Do not use Destination IDs with ACM/400 accounts. DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=19200 =M1 =M0 =\\Q3 =\\Q0 =%C1"H3 =%C0"H0 =\\N5 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 V1 X7 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATE0Q1S0=1 CONNECT="DIALIN_GATEWAY" CONNECT= CONNECT= CONNECT= ;---------------------------------------- [Supra COM CARD 144 PCMCIA] ALIAS=Megahertz XJack PCMCIA 144 DETECT_STRING=ATI3 DETECT_RESPONSE=Supra Corporation DETECT_STRING=ATI6 DETECT_RESPONSE=RC144DPL ;---------------------------------------- [SupraModem 2400] ALIAS=Hayes Compatible 2400 DETECT_STRING=ATI0 DETECT_RESPONSE=249 ;---------------------------------------- [Supra Fax Modem 9624 Internal] ALIAS=Hayes Compatible 2400 DETECT_STRING=ATI3 DETECT_RESPONSE=AFEP-C2501-H0 ;---------------------------------------- [Supra Fax Modem V32] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 =M1 =M0 =&K3 =&K0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=ATI5 DETECT_RESPONSE=Supra COMMAND_INIT=AT&F2&C1&D2 V1 W1 Q0 S7=55 COMMAND_INIT=AT S2=128 S11=55 S95=44 S0=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Supra Fax Modem V32bis] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =M1 =M0 =&K3 =&K0 =%C3 =%C0 = ;=\\N3 =\\N0 =ATDT =ATD DETECT_STRING=ATI5 DETECT_RESPONSE=Supra COMMAND_INIT=AT&F2&C1&D2 S7=55 COMMAND_INIT=ATS2=128 S11=55 S95=44 S0=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Supra Fax Modem 288] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=28800 MAXCONNECTBPS=57600 =M1 =M0 =&K3 =&K0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=ATI5 DETECT_RESPONSE=Supra DETECT_STRING=ATI DETECT_RESPONSE=28800 COMMAND_INIT=AT&F2&C1&D2 S7=55 COMMAND_INIT=ATS2=128 S11=55 S95=44 S0=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Supra Fax Modem 288 internal] ALIAS=Supra Fax Modem 288 DETECT_STRING=ATI5 DETECT_RESPONSE=Supra DETECT_STRING=ATI DETECT_RESPONSE=28800 ;---------------------------------------- [Supra Fax Modem Plus] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=9600 =M1 =M0 =&K3 =&K0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=TR00 DETECT_STRING=ATI5 DETECT_RESPONSE=Supra COMMAND_INIT=AT&F&C1&D2 V1 W1 Q0 COMMAND_INIT=ATS7=55 S2=128 S11=55 S95=44 S0=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Telebit QBlazer] ;Not tested as a server modem. CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 =M1 =M0 =S58=2 =S58=0 =S190=1 =S190=0 =S180=2 =S180=0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=QBlazer COMMAND_INIT=AT&F &C1 &D2 S0=0 S2=128 S7=55 S59=11 X4 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Telebit T1000] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 =M1 =M0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=FA2.10 COMMAND_INIT=AT~&F S53=1 S52=1 S58=0 S0=0 S55=3 S54=3 S7=55 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Telebit T1500] ;Server:untested ;This modem has not been tested as a server modem. This modem is not ;supported as a server modem. CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 =M1 =M0 =S58=2 S68=255 =S58=0 S68=255 =S97=1 S106=1 S98=0 =S98=0 =S95=2 S96=1 =S96=0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=T1500 COMMAND_INIT=AT~&F X13 S131=1 S52=1 S55=3 COMMAND_INIT=ATS110=0 S0=0 S55=3 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Telebit T1600] ;Advanced features are disabled CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 =M1 =M0 =S58=2 =S58=0 =S190=1 =S190=0 =S180=2 =S180=0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=T1600 COMMAND_INIT=AT&F &C1 &D2 S0=0 S2=128 S7=55 S59=11 X11 S58=0 S180=0 S181=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Telebit T2000] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=9600 =M1 =M0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=Version BC4.01 COMMAND_INIT=AT &F S52=1 S2=255 S0=0 S54=3 S7=55 S58=0 S180=0 S181=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Telebit T2500] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=19200 =M1 =M0 =S58=2 S68=255 =S58=0 S68=255 =S96=1 S98=3 =S96=0 S98=0 =S66=2 S95=2 S97=1 S106=1 =S66=0 S95=0 S97=0 S106=0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=T2500 COMMAND_INIT=AT~&F COMMAND_INIT=ATX14 S131=1 S52=1 S55=3 S55=3 S7=55 S50=6 S92=1 COMMAND_INIT=AT S50=6 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Telebit T3000] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 =M1 =M0 =S58=2 S68=255 =S58=0 S68=255 =S190=1 S180=2 =S190=0 =S180=2 =S180=0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=T3000 COMMAND_INIT=AT&F COMMAND_INIT=AT&C1&D2 X11 S0=0 S2=128 S7=55 S50=7 S59=9 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Telebit TrailBlazer Plus] ;PEP disabled with S50=3 S92=1. To re-enable PEP for 9600 baud ;connection with another Telebit, delete the string S50=3 S92=1. CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=19200 =M1 =M0 =S58=2 S68=255 =S58=0 S68=255 =S98=0 S110=0 =S98=3 =S97=1 S106=1 S95=2 =S97=0 S106=0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=GF7.03-TBSA COMMAND_INIT=AT~&F S52=4 S131=3 COMMAND_INIT=ATS51=255 S2=255 S0=0 S7=55 X3 COMMAND_INIT=ATS50=3 S92=1 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Telebit WorldBlazer] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =M1 =M0 =S58=2 S68=255 =S58=0 S68=255 =S180=2 S190=1 =S190=0 =S180=2 S190=0 =S180=0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=WorldBlazer COMMAND_INIT=AT&F COMMAND_INIT=AT&C1&D2 X11 S0=0 S2=128 S94=1 S92=1 S50=7 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Telebit WorldBlazer-Rackmount] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =M1 =M0 =S58=2 S68=255 =S58=0 S68=255 =S180=2 S190=1 =S190=0 =S180=2 S190=0 =S180=0 =ATDT =ATD COMMAND_INIT=AT&F COMMAND_INIT=AT&C1&D3 X11 S0=0 S2=128 S94=1 S92=1 S50=7 COMMAND_INIT=ATQ0 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [UDS Motorola CELLect 144] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N7 =\\N0 =ATDT =ATD DETECT_STRING=AT%V DETECT_RESPONSE=UDS CELLect 14.4 COMMAND_INIT=AT&F COMMAND_INIT=AT&C1&D2 \\V1 V3 S0=0 S2=128 S7=30 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [UDS Motorola FasTalk II] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N6 =\\N0 =ATDT =ATD DETECT_STRING=ATI4 DETECT_RESPONSE=UDS-144VBIS COMMAND_INIT=AT&F COMMAND_INIT=AT&C1&D2 \\V1 V3 S0=0 S2=128 S7=30 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [UDS Motorola V.3225] ;Advanced features disabled. CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 =M1 =M0 =ATDT =ATD DETECT_STRING=AT%V DETECT_RESPONSE=V3225 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 %C0 \\N1 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [UDS Motorola V.3227] ;Server: CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 ;MAXCONNECTBPS set to 9600 for reasons of stability. MAXCONNECTBPS=9600 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N7 =\\N0 =ATDT =ATD DETECT_STRING=AT%V DETECT_RESPONSE=V.3227 COMMAND_INIT=AT&F COMMAND_INIT=AT&C1&D2 \\V1 S0=0 S2=128 S7=30 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [UDS Motorola V.3229] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N7 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F COMMAND_INIT=AT&C1&D2 \\V1 S0=0 S2=128 S50=7 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [UDS Motorola FasTalk V.32/42b] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 ;Maxconnect set down to 9600 and advanced features disabled for stability. =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=AT%V DETECT_RESPONSE=FASTALK V.32/42b COMMAND_INIT=AT&F COMMAND_INIT=AT&C1&D2 \\V1 \\Q0 %C0 \\N0 S0=0 S2=128 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=\ CONNECT /REL CONNECT_EC=\ CONNECT /LAPM COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=\ CONNECT /REL CONNECT_EC=\ CONNECT /LAPM ;---------------------------------------- [UDS Motorola V.3400] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=28800 MAXCONNECTBPS=57600 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N7 =\\N0 =ATDT =ATD DETECT_STRING=AT%V DETECT_RESPONSE=V.3400 COMMAND_INIT=AT&F COMMAND_INIT=AT&C1&D2 \\V1 S0=0 S2=128 S7=30 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 [USRobotics General] ; This selection can be used by almost ALL USRobotics modems. ; ; A MAXCONNECTBPS of 38400 allows this to be used by older modems such ; as the HST 14400. ; ; Compression is off by default because of the lower DTE-DCE rate. ; ; ITU-T standards are on by default to ensure compatibility with ; non-USR modems. ; ; X4 is set to ensure compatibility with Sportster modems. Advanced ; dial features for Courier can be activated by placing X7 in the dial ; string. (e.g. phone number field contains "1-708-676-1059X7") CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=28800 MAXCONNECTBPS=38400 =m1 =m0 =&h1&r2 =&h0&r1 =&k3 =&k0 =&m4 =&m0 =ATdt =ATd ;removed s47=2 because most of the newer modems don't support it ;COMMAND_INIT=AT&f&a3x4e1q0v1s0=0s7=55s2=128s47=2 COMMAND_INIT=AT&f&a3x4e1q0v1s0=0s7=55s2=128 COMMAND_INIT=AT&b1&c1&d2b0x4 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [US Robotics Courier Dual] ALIAS=US Robotics Courier V.32bis DETECT_STRING=ATI4 DETECT_RESPONSE=USRobotics Courier 16800 HST Dual ;---------------------------------------- [US Robotics Courier HST] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=19200 =M1 =M0 =ATDT =ATD DETECT_STRING=ATI4 DETECT_RESPONSE=USRobotics Courier 14400 HST COMMAND_INIT=AT&F&C1&D2 V1 &B0 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [US Robotics Courier V.32bis] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 =M1 =M0 =&R2&H1 =&R1&H0 =&K1 =&K0 =&M4 =&M0 =ATDT =ATD DETECT_STRING=ATI4 DETECT_RESPONSE=USRobotics Courier V.32 COMMAND_INIT=ATE1&F&C1 &D2 &A1 &B1 V1 Q0 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /ARQ COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /ARQ ;---------------------------------------- [US Robotics Sportster 2400] ALIAS=Hayes Compatible 2400 DETECT_STRING=ATI4 DETECT_RESPONSE=SSi 73D2404 ;---------------------------------------- [US Robotics Sportster 9600] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 =M1 =M0 =&H1&R2 =&H0&R1 =&K1 =&K0 =&M4 =&M0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [US Robotics Sportster 14400] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 =M1 =M0 =&H1&R2 =&H0&R1 =&K1 =&K0 =&M4 =&M0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=Sportster 14,400 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT&B1 COMMAND_DIAL= CONNECT=\ CONNECT CONNECT_EC=\ CONNECT /ARQ COMMAND_LISTEN=ATS0=1 CONNECT=\ CONNECT CONNECT_EC=\ CONNECT /ARQ ;---------------------------------------- [US Robotics V32bis Quad Digital] ALIAS=US Robotics Sportster 14400 ;---------------------------------------- [US Robotics Worldport 14400] ALIAS=USR Worldport 14400 - UK DETECT_STRING=ATI3 DETECT_RESPONSE=WorldPort 14,400 ;---------------------------------------- [US Robotics Sportster 28800 VFC] ALIAS=USRobotics General DETECT_STRING=ATI3 DETECT_RESPONSE=Sportster 28,800 ;---------------------------------------- [US Robotics 288 PCMCIA] ALIAS=USRobotics General DETECT_STRING=ATI3 DETECT_RESPONSE=Sportster 28800 DETECT_RESPONSE=Sportster 33600 DETECT_STRING=ATI4 DETECT_RESPONSE=Sportster PCMCIA 28800 DETECT_RESPONSE=Sportster PCMCIA 33600 ;---------------------------------------- [US Robotics Sportster 28800 V34] ALIAS=USRobotics General DETECT_STRING=ATI3 DETECT_RESPONSE=Sportster 28800 DETECT_RESPONSE=Sportster 33600 ;---------------------------------------- [Ven-Tel 9600 Plus II] ;Compression forced ON. =M1 =M0 =ATDT =ATX3DT CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=38400 DETECT_STRING=ATI0 DETECT_RESPONSE=EC9600 Plus II COMMAND_INIT=AT&F&C1&D2 COMMAND_INIT=AT V1 X4 S0=0 S2=128 S7=55 COMMAND_INIT=AT \\Q3 \\N3 %C1 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=COMPRESSION NOT AVAILABLE\ CONNECT CONNECT=\ CONNECT CONNECT=\ COMPRESSION NOT AVAILABLE\ CONNECT TRELLIS CONNECT=\ CONNECT TRELLIS CONNECT_EC=\ COMPRESSION NOT AVAILABLE\ CONNECT TRELLIS/LAPM CONNECT_EC=CONNECT TRELLIS/LAPM CONNECT_EC=\ COMPRESS V.42bis\ CONNECT TRELLIS CONNECT_EC=\ COMPRESS V.42bis\ CONNECT TRELLIS/LAPM CONNECT_EC=\ COMPRESS V.42bis\ CONNECT TRELLIS CONNECT_EC=\ COMPRESS MNP5\ CONNECT TRELLIS/LAPM COMMAND_LISTEN=ATS0=1 CONNECT=COMPRESSION NOT AVAILABLE\ CONNECT CONNECT=\ CONNECT CONNECT=\ COMPRESSION NOT AVAILABLE\ CONNECT TRELLIS CONNECT=\ CONNECT TRELLIS CONNECT_EC=\ COMPRESSION NOT AVAILABLE\ CONNECT TRELLIS/LAPM CONNECT_EC=CONNECT TRELLIS/LAPM CONNECT_EC=\ COMPRESS V.42bis\ CONNECT TRELLIS CONNECT_EC=\ COMPRESS V.42bis\ CONNECT TRELLIS/LAPM CONNECT_EC=\ COMPRESS V.42bis\ CONNECT TRELLIS CONNECT_EC=\ COMPRESS MNP5\ CONNECT TRELLIS/LAPM ;---------------------------------------- [Ven-Tel Pocket 24 V.42bis FAX] =M1 =M0 =&K3 =&K0 =%C3 =%C0 =&Q5 =&Q0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=9600 DETECT_STRING=ATI3 DETECT_RESPONSE=TR00 COMMAND_INIT=AT&F&C1&D2 COMMAND_INIT=AT V1 X4 S0=0 S2=128 S7=55 S95=44 ;COMMAND_INIT=AT COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Ven-Tel 14400 Fax] =M1 =M0 =&K3 =&K0 =%C1 =%C0 =&Q5 =&Q0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 DETECT_STRING=ATI3 DETECT_RESPONSE=TR14 COMMAND_INIT=AT&F&C1&D2 COMMAND_INIT=AT V1 X4 W0 S0=0 S2=128 S7=55 S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Ven-Tel 14400 Fax Internal] ALIAS=Ven-Tel 14400 Fax DETECT_STRING=ATI3 DETECT_RESPONSE=TR14 ;---------------------------------------- [Ven-Tel ECV 32bis II] =M1 =M0 =\\Q3 =%F0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 DETECT_STRING=ATI DETECT_RESPONSE=ECV.32bis II COMMAND_INIT=AT&F&C1&D2 COMMAND_INIT=AT V1 X4 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=COMPRESSION NOT AVAILABLE\ CONNECT CONNECT=\ CONNECT CONNECT=\ COMPRESSION NOT AVAILABLE\ CONNECT TRELLIS CONNECT=\ CONNECT TRELLIS CONNECT_EC=\ COMPRESSION NOT AVAILABLE\ CONNECT TRELLIS/LAPM CONNECT_EC=CONNECT TRELLIS/LAPM CONNECT_EC=CONNECT TRELLIS/LAPM~CONNECT TRELLIS/REL CONNECT_EC=\ COMPRESS V.42bis\ CONNECT TRELLIS CONNECT_EC=\ COMPRESS V.42bis\ CONNECT TRELLIS/LAPM CONNECT_EC=\ COMPRESS V.42bis\ CONNECT TRELLIS CONNECT_EC=\ COMPRESS MNP5\ CONNECT TRELLIS/LAPM COMMAND_LISTEN=ATS0=1 CONNECT=COMPRESSION NOT AVAILABLE\ CONNECT CONNECT=\ CONNECT CONNECT=\ COMPRESSION NOT AVAILABLE\ CONNECT TRELLIS CONNECT=\ CONNECT TRELLIS CONNECT_EC=\ COMPRESSION NOT AVAILABLE\ CONNECT TRELLIS/LAPM CONNECT_EC=CONNECT TRELLIS/LAPM CONNECT_EC=CONNECT TRELLIS/LAPM~CONNECT TRELLIS/REL CONNECT_EC=\ COMPRESS V.42bis\ CONNECT TRELLIS CONNECT_EC=\ COMPRESS V.42bis\ CONNECT TRELLIS/LAPM CONNECT_EC=\ COMPRESS V.42bis\ CONNECT TRELLIS CONNECT_EC=\ COMPRESS MNP5\ CONNECT TRELLIS/LAPM ;---------------------------------------- [ViVa 144 Fax] ALIAS=Hayes Optima 14400 ;---------------------------------------- [Western Datacom Worldcom] =M1 =M0 =&K3 =&K0 =%C1 =%C0 =\\N7 =\\N0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 DETECT_STRING=ATI3 DETECT_RESPONSE=WESTERN DATACOM WORLDCOM COMMAND_INIT=AT&F&C1&D2 COMMAND_INIT=AT V1 W1 X4 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT_EC=\ CARRIER \ PROTOCOL: MNP REL\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: V42\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: V42BIS\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: MNP REL\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: V42\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: V42BIS\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ CONNECT CONNECT=CONNECT ;Not supported as a server modem. COMMAND_LISTEN=ATS0=1 CONNECT_EC=\ CARRIER \ PROTOCOL: MNP REL\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: V42\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: V42BIS\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: MNP REL\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: V42\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: V42BIS\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ CONNECT CONNECT=CONNECT ;---------------------------------------- [Xircom Ethernet+Modem PCMCIA] =&K0 =&K3 =&Q0 =&Q5 =S46=136 =S46=2 =M1 =M0 =ATDT =ATX3D CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 DETECT_STRING=ATI3 DETECT_RESPONSE=CreditCard Ethernet+Modem COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Zoom AFX] ALIAS=Hayes Compatible 2400 ;---------------------------------------- [Zoom FX 9624V] =M1 =M0 =&K3 =&K0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=9600 DETECT_STRING=ATI3 DETECT_RESPONSE=096 COMMAND_INIT=AT&F&C1&D2 COMMAND_INIT=AT V1 X4 S0=0 S2=128 S7=55 S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Zoom VFX V.32bis] =M1 =M0 =&K3 =&K0 =%C1 =%C0 =&Q5 =&Q0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 DETECT_STRING=ATI3 DETECT_RESPONSE=VFX14.4 DETECT_RESPONSE=TR14 COMMAND_INIT=AT&F&C1&D2 COMMAND_INIT=AT V1 X4 S0=0 S2=128 S7=55 S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Zoom VFP 28.8 internal] =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=28800 MAXCONNECTBPS=57600 DETECT_STRING=ATI3 DETECT_RESPONSE=VFP DETECT_RESPONSE=VFC DETECT_STRING=ATI DETECT_RESPONSE=28800 COMMAND_INIT=AT&F&C1&D2 COMMAND_INIT=AT V1 W1 X4 S0=0 S2=128 S7=55 S95=44 COMMAND_INIT=AT COMMAND_DIAL= CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ COMPRESSION: V.42BIS\ CONNECT COMMAND_LISTEN=ATS0=1 CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ COMPRESSION: V.42BIS\ CONNECT ;---------------------------------------- [ZyXel U-1496] ;Cannot toggle EC and DC entirely independently in ZyXel. =M1 =M0 =&H3 =&H0 =&K4 =&K0 =&K3 =&K0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF= MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 DETECT_STRING=ATI0 DETECT_RESPONSE=1496 COMMAND_INIT=AT&F&C1&D2 COMMAND_INIT=ATV1 X5 S0=0S2=128 S7=55 S35=2 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 COMMAND_DIAL= ;---------------------------------------- [ZyXel U-1496B] ALIAS=ZyXel U-1496 ;---------------------------------------- [ZyXel U-1496E] ALIAS=ZyXel U-1496 DETECT_STRING=ATI0 DETECT_RESPONSE=1496E ;---------------------------------------- [ZyXel U-1496] ALIAS=ZyXel U-1496 ;---------------------------------------- [ZyXel U-1496E+] ALIAS=ZyXel U-1496 ;---------------------------------------- [ZyXel U-1496B+] ALIAS=ZyXel U-1496 ;---------------------------------------- [ZyXel U-1496+] ALIAS=ZyXel U-1496 ;---------------------------------------- [ZyXel U-1496P] ALIAS=ZyXel U-1496 ;---------------------------------------- ; UK MODEMS ;---------------------------------------- ;---------------------------------------- [Hayes Ultra 14400 - UK] ALIAS=Hayes Optima 14400 ;---------------------------------------- [Smartlink Pocket 2400 - UK] ALIAS=Hayes Compatible 2400 ;---------------------------------------- [Smartlink V32Bis/Fax - UK] CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F. COMMAND_INIT=AT&C1&D2 \\V1 X1 W2 Q0 S0=0 S2=128 S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL ;---------------------------------------- [Dataflex Rapier+ V32Bis - UK] CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2Q0V1E1\\J1S0=0S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT ;---------------------------------------- [Psion Dacom PDM 50F - UK] CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2Q0V1E1S0=0S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT ;---------------------------------------- ;Please note that this modem does NOT support 14,400bps DTE speed. [Andest Rocket - UK] =M1 =M0 =$F4 =$F5 =$C1 =$C0 =$E3 =$E0 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 COMMAND_INIT=AT&F&C1&D2 $X2 V1 S0=0 S2=128 S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT ALT CONNECT_EC=CONNECT ALT /MNP 5 CONNECT_EC=CONNECT LAPM CONNECT_EC=CONNECT LAPM /V.42bis COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT ALT CONNECT_EC=CONNECT ALT /MNP 5 CONNECT_EC=CONNECT LAPM CONNECT_EC=CONNECT LAPM /V.42bis ;---------------------------------------- [Intel SatisFaxtion - UK] ALIAS=Hayes Compatible 2400 ;--------------------------------------------------------------------------- ; This modem does not support callback when connecting to MS RAS 1.x Servers ;--------------------------------------------------------------------------- [USR Worldport 14400 - UK] CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =&R2&H1 =&R1&H0 =&K1 =&K0 =&M4 =&M0 =ATDT =ATD COMMAND_INIT=AT&F&C1 &D2 &A3 &B1 V1 Q0 S0=0 S2=128 S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=\ CONNECT CONNECT_EC=\ CONNECT /NONE CONNECT_EC=\ CONNECT /V32/NONE CONNECT_EC=\ CONNECT /ARQ CONNECT_EC=\ CONNECT /ARQ/V32 CONNECT_EC=\ CONNECT /ARQ/LAPM CONNECT_EC=\ CONNECT /ARQ/LAPM/V42BIS CONNECT_EC=\ CONNECT /ARQ/V32/LAPM CONNECT_EC=\ CONNECT /ARQ/V32/LAPM/V42BIS CONNECT_EC=\ CONNECT /ARQ/MNP CONNECT_EC=\ CONNECT /ARQ/MNP/MNP5 CONNECT_EC=\ CONNECT /ARQ/V32/MNP CONNECT_EC=\ CONNECT /ARQ/V32/MNP/MNP5 COMMAND_LISTEN=ATS0=1 CONNECT=\ CONNECT CONNECT_EC=\ CONNECT /NONE CONNECT_EC=\ CONNECT /V32/NONE CONNECT_EC=\ CONNECT /ARQ CONNECT_EC=\ CONNECT /ARQ/V32 CONNECT_EC=\ CONNECT /ARQ/LAPM CONNECT_EC=\ CONNECT /ARQ/LAPM/V42BIS CONNECT_EC=\ CONNECT /ARQ/V32/LAPM CONNECT_EC=\ CONNECT /ARQ/V32/LAPM/V42BIS CONNECT_EC=\ CONNECT /ARQ/MNP CONNECT_EC=\ CONNECT /ARQ/MNP/MNP5 CONNECT_EC=\ CONNECT /ARQ/V32/MNP CONNECT_EC=\ CONNECT /ARQ/V32/MNP/MNP5 ;---------------------------------------- ; SWEDISH MODEMS ;---------------------------------------- ;---------------------------------------- [GVC SM2400 - SWE] ALIAS=Hayes Compatible 2400 ;---------------------------------------- [GVC SM96 - SWE] CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=19200 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N6 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2Q0V1E1S0=0S2=128S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP/COMPRESSED CONNECT_EC=CONNECT /MNP COMPRESSED CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP/COMPRESSED CONNECT_EC=CONNECT /MNP COMPRESSED CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP/COMPRESSED CONNECT_EC=CONNECT /MNP COMPRESSED CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP/COMPRESSED CONNECT_EC=CONNECT /MNP COMPRESSED CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS ;---------------------------------------- [GVC FM14400 - SWE] CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N6 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2Q0V1E1S0=0S2=128 S7=60 S95=44 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP/COMPRESSED CONNECT_EC=CONNECT /MNP COMPRESSED CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP/COMPRESSED CONNECT_EC=CONNECT /MNP COMPRESSED CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS ;---------------------------------------- [Hidem 14400/FAX - SWE] =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N6 =\\N0 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=19200 COMMAND_INIT=AT&F&C1&D2 \\V1 V1 W2S0=0 S2=128 S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS ;---------------------------------------- ;Hardware flow control and error correction are set ON for stability. ;For stability keep DTE at 9600bps. [Hidem 2442P/FAX - SWE] =M1 =M0 =\\Q3 =\\Q3 =%C1 =%C0 =\\N7 =\\N7 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=9600 COMMAND_INIT=AT&F&C1&D2 \\V1 V1 X4S0=0 S2=128 S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT ERROR_NO_CARRIER=NO CARRIER CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS COMMAND_LISTEN=ATS0=1 ERROR_NO_CARRIER=NO CARRIER CONNECT=CONNECT CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS ;---------------------------------------- [LASAT Unique 144 - SWE] =L2M1 =M0 =&K3 =&K0 =%C2 =%C0 =\\N3 =\\N0 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF=speaker compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 COMMAND_INIT=AT&F&C1&D2W1 COMMAND_INIT=AT V1 X4 S0=0 S2=128 S7=60 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;--------------------------------------------------------------------------- ; This modem does not support callback when connecting to MS RAS 1.x Servers ;--------------------------------------------------------------------------- [LIGHTFAX 1440LC - SWE] CALLBACKTIME=15 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=14400 =M1 =M0 =&K3 =&K0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 E1 V1 W1 X4 S0=0 S7=60 S2=128 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;------------------------------------------- [MultiTech MT932 - SWE] =M1 =M0 =&E4 =&E3 =&E15 =&E14 =&E1 =&E0 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=19200 COMMAND_INIT=AT&SF1&S0&W COMMAND_INIT=AT E1 COMMAND_INIT=AT &F &C1 V1 &D2 &Q0 X4 &S0 S0=0 S2=128 S7=60 $BA0 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT RELIABLE CONNECT_EC=CONNECT LAPM CONNECT_EC=CONNECT RELIABLE COMPRESSED CONNECT_EC=CONNECT LAPM COMPRESSED COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT RELIABLE CONNECT_EC=CONNECT LAPM CONNECT_EC=CONNECT RELIABLE COMPRESSED CONNECT_EC=CONNECT LAPM COMPRESSED ;------------------------------------------------------------------------ ; Hardware flow control and error correction are set ON for stability. ; ; Connecting to modems with Advanced features may fail due to Guard tone ; feature. ;------------------------------------------------------------------------ [UCOM FASTLINK 144 - SWE] =L2M1 =M0 =&K3 =&K3 =%C2 =%C0 =\\N3 =\\N3 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF=speaker compression MAXCARRIERBPS=14400 MAXCONNECTBPS=14400 COMMAND_INIT=AT&F&C1&D2N0&G0W1 COMMAND_INIT=AT V1 X4 S0=0 S2=128 S7=60 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [UCOM TRAVELLER 144 - SWE] alias=UCOM FASTLINK 144 - SWE ;---------------------------------------- [UDS Motorola FasTalk V32- SWE] CALLBACKTIME=20 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 ;Maxconnect set down to 9600 and advanced features disabled for stability. =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F COMMAND_INIT=AT&C1&D2 \\V1 \\Q0 %C0 \\N0 S0=0 S2=128 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=\ CONNECT /REL CONNECT_EC=\ CONNECT /LAPM COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=\ CONNECT /REL CONNECT_EC=\ CONNECT /LAPM ;--------------------------------------------------------------------------- ; Please note that this modem does NOT support 14,400bps DTE speed. ;--------------------------------------------------------------------------- ; This modem does not support callback when connecting to MS RAS 1.x Servers ;--------------------------------------------------------------------------- [UFOMATE P1496MX - SWE] =M1 =M0 =$F4 =$F5 =$C1 =$C0 =$E3 =$E0 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 COMMAND_INIT=AT&F&C1&D2 $X2 V1 S0=0 S2=128 S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT ALT CONNECT_EC=CONNECT ALT /MNP 5 CONNECT_EC=CONNECT LAPM CONNECT_EC=CONNECT LAPM /V.42bis COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT ALT CONNECT_EC=CONNECT ALT /MNP 5 CONNECT_EC=CONNECT LAPM CONNECT_EC=CONNECT LAPM /V.42bis ;---------------------------------------- [USR Courier V.32bis - SWE] CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=19200 =M1 =M0 =&R2&H1 =&R1&H0 =&K1 =&K0 =&M4 =&M0 =ATDT =ATD COMMAND_INIT=AT&F&C1 &D2 &A1 &B1 V1 Q0 S0=0 S2=128 S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /ARQ COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /ARQ ;---------------------------------------- ;Please note that this modem does NOT support 14,400bps DTE speed. [USR Sportster 14400 - SWE] CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=19200 =M1 =M0 =&H1&R2 =&H0&R1 =&K1 =&K0 =&M4 =&M0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 &A3V1 S0=0 S2=128 S7=60 COMMAND_INIT=AT&B1 COMMAND_DIAL= CONNECT=\ CONNECT CONNECT_EC=\ CONNECT /NONE CONNECT_EC=\ CONNECT /V32/NONE CONNECT_EC=\ CONNECT /ARQ CONNECT_EC=\ CONNECT /ARQ/V32 CONNECT_EC=\ CONNECT /ARQ/LAPM CONNECT_EC=\ CONNECT /ARQ/LAPM/V42BIS CONNECT_EC=\ CONNECT /ARQ/V32/LAPM CONNECT_EC=\ CONNECT /ARQ/V32/LAPM/V42BIS CONNECT_EC=\ CONNECT /ARQ/MNP CONNECT_EC=\ CONNECT /ARQ/MNP/MNP5 CONNECT_EC=\ CONNECT /ARQ/V32/MNP CONNECT_EC=\ CONNECT /ARQ/V32/MNP/MNP5 COMMAND_LISTEN=ATS0=1 CONNECT=\ CONNECT CONNECT_EC=\ CONNECT /NONE CONNECT_EC=\ CONNECT /V32/NONE CONNECT_EC=\ CONNECT /ARQ CONNECT_EC=\ CONNECT /ARQ/V32 CONNECT_EC=\ CONNECT /ARQ/LAPM CONNECT_EC=\ CONNECT /ARQ/LAPM/V42BIS CONNECT_EC=\ CONNECT /ARQ/V32/LAPM CONNECT_EC=\ CONNECT /ARQ/V32/LAPM/V42BIS CONNECT_EC=\ CONNECT /ARQ/MNP CONNECT_EC=\ CONNECT /ARQ/MNP/MNP5 CONNECT_EC=\ CONNECT /ARQ/V32/MNP CONNECT_EC=\ CONNECT /ARQ/V32/MNP/MNP5 ;---------------------------------------- [USR Worldport 14400 - SWE] CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=19200 =M1 =M0 =&R2&H1 =&R1&H0 =&K1 =&K0 =&M4 =&M0 =ATDT =ATD COMMAND_INIT=AT&F&C1 &D2 &A3 &B1 V1 Q0 S0=0 S2=128 S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=\ CONNECT CONNECT_EC=\ CONNECT /NONE CONNECT_EC=\ CONNECT /V32/NONE CONNECT_EC=\ CONNECT /ARQ CONNECT_EC=\ CONNECT /ARQ/V32 CONNECT_EC=\ CONNECT /ARQ/LAPM CONNECT_EC=\ CONNECT /ARQ/LAPM/V42BIS CONNECT_EC=\ CONNECT /ARQ/V32/LAPM CONNECT_EC=\ CONNECT /ARQ/V32/LAPM/V42BIS CONNECT_EC=\ CONNECT /ARQ/MNP CONNECT_EC=\ CONNECT /ARQ/MNP/MNP5 CONNECT_EC=\ CONNECT /ARQ/V32/MNP CONNECT_EC=\ CONNECT /ARQ/V32/MNP/MNP5 COMMAND_LISTEN=ATS0=1 CONNECT=\ CONNECT CONNECT_EC=\ CONNECT /NONE CONNECT_EC=\ CONNECT /V32/NONE CONNECT_EC=\ CONNECT /ARQ CONNECT_EC=\ CONNECT /ARQ/V32 CONNECT_EC=\ CONNECT /ARQ/LAPM CONNECT_EC=\ CONNECT /ARQ/LAPM/V42BIS CONNECT_EC=\ CONNECT /ARQ/V32/LAPM CONNECT_EC=\ CONNECT /ARQ/V32/LAPM/V42BIS CONNECT_EC=\ CONNECT /ARQ/MNP CONNECT_EC=\ CONNECT /ARQ/MNP/MNP5 CONNECT_EC=\ CONNECT /ARQ/V32/MNP CONNECT_EC=\ CONNECT /ARQ/V32/MNP/MNP5 ;---------------------------------------- [DYNALINK - SWE] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =M1 =M0 =&K3 =&K0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 L3 V1 W1 S0=0 S2=43 S7=55 S95=5 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 [SBN 2314C - SWE] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=14400 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT &F &D2 +Q3 V1 S0=1 S2=128 S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT=CONNECT / CONNECT=CONNECT //TCM CONNECT_EC=CONNECT /REL/ V.42BIS CONNECT_EC=CONNECT /REL/ V.42BIS/TCM CONNECT_EC=CONNECT /REL/ V.42BIS/TCM CONNECT_EC=CONNECT /REL// V.42BIS/TCM CONNECT_EC=CONNECT /REL/ LAPM CONNECT_EC=CONNECT /REL/ LAPM/TCM CONNECT_EC=CONNECT /REL/ LAPM/TCM CONNECT_EC=CONNECT /REL/ CONNECT_EC=CONNECT /REL/ COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT=CONNECT / CONNECT=CONNECT //TCM CONNECT_EC=CONNECT /REL/ V.42BIS CONNECT_EC=CONNECT /REL/ V.42BIS/TCM CONNECT_EC=CONNECT /REL/ V.42BIS/TCM CONNECT_EC=CONNECT /REL// V.42BIS/TCM CONNECT_EC=CONNECT /REL/ LAPM CONNECT_EC=CONNECT /REL/ LAPM/TCM CONNECT_EC=CONNECT /REL/ LAPM/TCM CONNECT_EC=CONNECT /REL/ CONNECT_EC=CONNECT /REL/ [SEMAFOR 2324C - SWE] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=9600 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT &F &D2 +Q2 V1 S0=1 S2=128 S7=60 +C1 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT=CONNECT / CONNECT=CONNECT //TCM CONNECT_EC=CONNECT /REL/ V.42BIS CONNECT_EC=CONNECT /REL/ V.42BIS/TCM CONNECT_EC=CONNECT /REL/ V.42BIS/TCM CONNECT_EC=CONNECT /REL// V.42BIS/TCM CONNECT_EC=CONNECT /REL/ LAPM CONNECT_EC=CONNECT /REL/ LAPM/TCM CONNECT_EC=CONNECT /REL/ LAPM/TCM CONNECT_EC=CONNECT /REL/ CONNECT_EC=CONNECT /REL/ COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT=CONNECT / CONNECT=CONNECT //TCM CONNECT_EC=CONNECT /REL/ V.42BIS CONNECT_EC=CONNECT /REL/ V.42BIS/TCM CONNECT_EC=CONNECT /REL/ V.42BIS/TCM CONNECT_EC=CONNECT /REL// V.42BIS/TCM CONNECT_EC=CONNECT /REL/ LAPM CONNECT_EC=CONNECT /REL/ LAPM/TCM CONNECT_EC=CONNECT /REL/ LAPM/TCM CONNECT_EC=CONNECT /REL/ CONNECT_EC=CONNECT /REL/ [SEMAFOR 1496A - SWE] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT &F &D2 +Q3 V1 S0=1 S2=128 S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT=CONNECT / CONNECT=CONNECT //TCM CONNECT_EC=CONNECT /REL/ V.42BIS CONNECT_EC=CONNECT /REL/ V.42BIS/TCM CONNECT_EC=CONNECT /REL/ V.42BIS/TCM CONNECT_EC=CONNECT /REL// V.42BIS/TCM CONNECT_EC=CONNECT /REL/ LAPM CONNECT_EC=CONNECT /REL/ LAPM/TCM CONNECT_EC=CONNECT /REL/ LAPM/TCM CONNECT_EC=CONNECT /REL/ CONNECT_EC=CONNECT /REL/ COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT=CONNECT / CONNECT=CONNECT //TCM CONNECT_EC=CONNECT /REL/ V.42BIS CONNECT_EC=CONNECT /REL/ V.42BIS/TCM CONNECT_EC=CONNECT /REL/ V.42BIS/TCM CONNECT_EC=CONNECT /REL// V.42BIS/TCM CONNECT_EC=CONNECT /REL/ LAPM CONNECT_EC=CONNECT /REL/ LAPM/TCM CONNECT_EC=CONNECT /REL/ LAPM/TCM CONNECT_EC=CONNECT /REL/ CONNECT_EC=CONNECT /REL/ ;---------------------------------------- ;---------------------------------------- ; AUSTRALIAN MODEMS ;---------------------------------------- ;---------------------------------------- [Avtek CD900 - AUS] CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 =M1 =M0 =ATDT =ATD COMMAND_INIT=AT&F+C61B0X1&C1&D2 S0=0 S7=60 COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /ARP CONNECT_EC=CONNECT /V42BIS COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /ARP ;-------------------------------------- ; This modem does not support callback ;-------------------------------------- [Avtek CD930 - AUS] =&K0 =&K3 =\\N0 =\\N3 =%C0 =%C3 =M0 =M1 =ATDT =ATX1D CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 COMMAND_INIT=AT&F&C1&D2 X1 W2 S0=0 S2=128 S7=60 COMMAND_INIT=AT COMMAND_DIAL= LOOP=RINGING COMMAND_LISTEN=ATS0=2 LOOP=RINGING CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M/HDX\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M/HDX\ COMPRESSION: MNP5\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: MNP5\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M/HDX\ COMPRESSION: MNP4\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: MNP4\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT /ARQ CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M/HDX\ CONNECT CONNECT_EC=\ CARRIER \ PROTOCOL: LAP-M\ CONNECT ;-------------------------------------- ; This modem does not support callback ;-------------------------------------- [Banksia XM124/R FAXMODEM- AUS] =M1 =M0 =ATDT =ATD CALLBACKTIME=30 MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 DEFAULTOFF=compression COMMAND_INIT=AT&F&C1&D2 S0=0 V1 X1 S2=128 S7=60 COMMAND_LISTEN=ATS0=2 COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /ARP CONNECT_EC=CONNECT /V42BIS COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /ARP ;---------------------------------------- [Banksia MX-6 V.32bis - AUS] =&K0 =&K3 =\\N0 =\\N3 =%C0 =%C3 =M0 =M1 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 COMMAND_INIT=AT&F&C1&D2 X1 V1 N1 S0=0 S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT /ARQ\ CONNECT_EC=CONNECT /ARQ\ COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT /ARQ\ CONNECT_EC=CONNECT /ARQ\ ; V.42BIS Compression with Protocol ALT,MNP5,LAP-M,MNP4,MNP3,MNP2,NONE CONNECT_EC=\ CARRIER \ COMPRESSION: V.42BIS\ PROTOCOL: NONE\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: V.42BIS\ PROTOCOL: MNP2\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: V.42BIS\ PROTOCOL: MNP3\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: V.42BIS\ PROTOCOL: MNP4\ CONNECT CARRIER \ COMPRESSION: V.42BIS\ PROTOCOL: LAP-M\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: V.42BIS\ PROTOCOL: MNP5\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: VVV.42BIS\ PROTOCOL: ALT\ CONNECT /ARQ ; End of compression for V.42bis ; CLASS5 Compression with Protocol ALT,MNP5,LAP-M,MNP4,MNP3,MNP2,NONE CONNECT_EC=\ CARRIER \ COMPRESSION: CLASS5\ PROTOCOL: NONE\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: CLASS5\ PROTOCOL: MNP2\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: CLASS5\ PROTOCOL: MNP3\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: CLASS5\ PROTOCOL: MNP4\ CONNECT CARRIER \ COMPRESSION: CLASS5\ PROTOCOL: LAP-M\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: CLASS5\ PROTOCOL: MNP5\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: CLASS5\ PROTOCOL: ALT\ CONNECT /ARQ ; End of compression for CLASS5 Compression. ; NONE Compression with Protocol ALT,MNP5,LAP-M,MNP4,MNP3,MNP2,NONE CONNECT_EC=\ CARRIER \ COMPRESSION: NONE\ PROTOCOL: NONE\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: NONE\ PROTOCOL: MNP2\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: NONE\ PROTOCOL: MNP3\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: NONE\ PROTOCOL: MNP4\ CONNECT CARRIER \ COMPRESSION: NONE\ PROTOCOL: LAP-M\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: NONE\ PROTOCOL: MNP5\ CONNECT CONNECT_EC=\ CARRIER \ COMPRESSION: NONE\ PROTOCOL: ALT\ CONNECT /ARQ ; End of compression for NONE Compression. ;---------------------------------------- [Maestro RC224FMI - AUS] =M1 =M0 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 COMMAND_INIT=AT&F&C1&D2 V1 X1 S0=0 S2=128 S7=55 COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /ARP CONNECT_EC=CONNECT /V42BIS COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /ARP ;---------------------------------------- [Maestro 144FMEI - AUS] =&K0 =&K3 =\\N0 =\\N3 =%C0 =%C1 =M0 =M1 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 COMMAND_INIT=AT&F&C1&D2 X1 S0=0 S2=128 S7=60 COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /ARP CONNECT_EC=CONNECT /V42BIS COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /ARP ;------------------------------------------------------ [Netcomm Pocket Rocket PA- AUS] =&K0 =&K3 =\\N0 =\\N3 =%C0 =%C3 =M0 =M1 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=9600 MAXCONNECTBPS=19200 COMMAND_INIT=AT&F&C1&D2 V1 X1 W1 S95=2 S0=0 S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /ARP CONNECT_EC=CONNECT /V42BIS COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /ARP ;---------------------------------------- [Netcomm Smartmodem E7F - AUS] =&K0 =&K3 =\\N0 =\\N3 =%C0 =%C3 =M0 =M1 =ATDT =ATX1D CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 COMMAND_INIT=AT&F. COMMAND_INIT=AT&C1&D2 X1 \\V1 Q0 S0=0 S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /ARP CONNECT_EC=CONNECT /V42BIS COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /ARP ;--------------------------------------------- [Netcomm Pocket M/F 2400-AUS] =M1 =M0 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 COMMAND_INIT=AT&F&C1&D2 V1 X1 S0=0 S2=128 S7=55 COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /ARP CONNECT_EC=CONNECT /V42BIS COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /ARP ;---------------------------------------- ; German Modems ;---------------------------------------- ;----------------- ; ComCom - Modems ;----------------- [ComCom Spirit II - GER] =M1 =M0 =*F3 =*F0 =*E9 = =*E5 =*E0 =ATDP =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 DETECT_STRING=AT*O DETECT_RESPONSE=MODEL:SPIRIT II COMMAND_INIT=AT&F&C1&D2 X3 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT*M1 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [ComCom Spirit TERBO - GER] =M1 =M0 =*F3 =*F0 =*E9 = =*E5 =*E0 =ATDP =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 DETECT_STRING=AT*O DETECT_RESPONSE=MODEL:SPIRIT TERBO COMMAND_INIT=AT&F&C1&D2 X3 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT*M1 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Compaq SpeedPAQ 144 - GER] =M1 =M0 =\\Q3 =\\Q0 =\\N3 =\\N0 =%C1 =%C0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=38400 DETECT_STRING=ATI9 DETECT_RESPONSE=Compaq COMMAND_INIT=AT&F&C1&D2 V1 W2S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT ;---------------------------------------- ; Creatix Polymedia Modems ;---------------------------------------- [Creatix LC144VF - GER] =&K0 =&K3 =\\N0 =\\N3 =%C0 =%C3 =M0 =M1 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=57600 DETECT_STRING=ATI4 DETECT_RESPONSE=Creatix Polymedia GmbH V1.41 29/11/93 DETECT_RESPONSE=Creatix Polymedia GmbH V1.5 27/05/94 COMMAND_INIT=AT&F0 W1 S95=46 S7=55 S2=128 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [Creatix LC288FC - GER] =&K0 =&K3 =\\N0 =\\N3 =%C0 =%C3 =M0 =M1 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=28800 MAXCONNECTBPS=115200 DETECT_STRING=ATI4 DETECT_RESPONSE=Creatix Polymedia GmbH V0.51 01/05/94 COMMAND_INIT=AT&F0 W1 S95=46 S7=55 S2=128 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;============== ; CTK - Modems ;============== [CTK SHORTY 144 SL - GER] DETECT_STRING=ATI4 DETECT_RESPONSE=FM-VBIS+/R1 V3.1s DETECT_RESPONSE=PICO T 14.4--D-LL CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N6 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F2X3&C1&D2Q0V1E1S0=0S2=128 S7=60 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP/COMPRESSED CONNECT_EC=CONNECT /MNP COMPRESSED CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /MNP CONNECT_EC=CONNECT /MNP/COMPRESSED CONNECT_EC=CONNECT /MNP COMPRESSED CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS ;---------------------------------------- ; Dr. Neuhaus Modems ; ; Alle folgenden Einstellungen haben in der INIT-Zeile ; COMMAND_INIT den Parameter W0 eingetragen. Das bedeu- ; tet, daá in der Connectmeldung immer die Datenrate ; zwischen dem Modem und dem Rechner angegeben wird. ; Hierdurch, und durch die Einstellung insgesamt, wird ; immer der maximal m”gliche Transferrate (ohne Umschalten) ; erreicht. Auch dann, wenn die Gegenstation evtl. nur mit ; niedrigeren Raten arbeitet. ; ;---------------------------------------- [Dr Neuhaus Fury 14400 TI - GER] =M1 =M0 =ATDT =ATD = = =\\N6 =\\N0 =\\Q3 =\\Q0 CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=38400 MAXCONNECTBPS=38400 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 W0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 CONNECT_EC=CONNECT /REL ;---------------------------------------- [Dr Neuhaus Fury 19200 TI - GER] =M1 =M0 =ATDT =ATD = = =\\N6 =\\N0 =\\Q3 =\\Q0 CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=57600 MAXCONNECTBPS=57600 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 W0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 CONNECT_EC=CONNECT /REL ;---------------------------------------- [Dr Neuhaus Smarty 144 TI - GER] =M1 =M0 =ATDT =ATD = = =\\N6 =\\N0 =\\Q3 =\\Q0 CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=38400 MAXCONNECTBPS=38400 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 W0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 CONNECT_EC=CONNECT /REL ;---------------------------------------- [Dr Neuhaus Smarty 24 TI - GER] =M1 =M0 =ATDT =ATD = = = = = = CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 ; Bevorzugte Einstellung: V42-Betrieb COMMAND_INIT=AT&F3 V1 S0=0 S2=128 S7=55 W0 ; Auch m”glich: MNP5-Betrieb ; COMMAND_INIT=AT&F2 V1 S0=0 S2=128 S7=55 W0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL [Dr Neuhaus Fury Card 24 - GER] alias=Dr Neuhaus Smarty 24 TI - GER [Dr Neuhaus Fury Card 144 - GER] alias=Dr Neuhaus Smarty 144 TI - GER [Dr Neuhaus SMARTY 19200 - GER] alias=Dr Neuhaus FURY 19200 TI - GER ;---------------------------------------- [Dr Neuhaus Niccy 3000 TI - GER] ; obwohl dieses Modem eigentlich in die Gruppe ISDN geh”ren ; k”nnte, wird es genau wie ein Modem angesprochen: = = =ATDT =ATD = = = = = = CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=38400 MAXCONNECTBPS=38400 COMMAND_INIT=AT COMMAND_INIT=AT&C1&D2\\Q3 COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 CONNECT_EC=CONNECT CONNECT=CONNECT ;---------------------------------------- [Dr Neuhaus Fury 2403 TI - GER] =M1 =M0 =ATDT =ATD =&Q5 =&Q0 = = =\\Q3 =\\Q0 CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 COMMAND_INIT=AT&F0&C1&D2 V1 S0=0 S2=128 S7=55 W1 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;-------------- ; EEH - Modems ;-------------- [EEH Elink 32 - GER] =\\Q0 =\\Q3 =\\N0 =\\N3 =%C0 =%C1 =M0 =M1 DETECT_STRING=ATI DETECT_RESPONSE=Elink 32 CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=57600 COMMAND_INIT=AT&F COMMAND_INIT=AT%C0 S2=128 COMMAND_INIT=AT COMMAND_DIAL=ATD COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL CONNECT_EC=CONNECT /RELC CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42B [EEH Elink 32-3 analog - GER] =\\Q0 =\\Q3 =\\N0 =\\N3 =%C0 =\\N3%C1 =M0 =M1 DETECT_STRING=ATI DETECT_RESPONSE=Elink 32-3 CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=115200 COMMAND_INIT=AT&F COMMAND_INIT=X1 &B0 %C0 S2=128 COMMAND_INIT=AT COMMAND_DIAL=ATD COMMAND_LISTEN=ATS0=1 CONNECT_EC=CONNECT /REL CONNECT_EC=CONNECT /RELC CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42B [EEH Elink 29-3 analog - GER] =\\Q0 =\\Q3 =\\N0 =\\N3 =%C0 =\\N3%C1 =M0 =M1 DETECT_STRING=ATI DETECT_RESPONSE=Elink 29-3 CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=115200 COMMAND_INIT=AT&F COMMAND_INIT=ATX1 &B0 %C0 S2=128 COMMAND_INIT=AT COMMAND_DIAL=ATD COMMAND_LISTEN=ATS0=1 CONNECT_EC=CONNECT /REL CONNECT_EC=CONNECT /RELC CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42B [EEH Elink 301 - GER] =\\Q0 =\\Q3 =\\N0 =\\N6 =M =M =M0 =M1 DETECT_STRING=ATI DETECT_RESPONSE=ELINK 301 CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=64000 MAXCONNECTBPS=115200 COMMAND_INIT=AT&F COMMAND_INIT=ATX1 \\N6 S12=128 S16=1 COMMAND_INIT=AT COMMAND_DIAL=ATD COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT /V.110 CONNECT_EC=CONNECT /X.75 [EEH Elink 310 - GER] =\\Q0 =\\Q3 =&B34 =&B49 =%C0 =%C1 =M0 =M1 DETECT_STRING=ATI DETECT_RESPONSE=Elink 310 CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=64000 MAXCONNECTBPS=115200 COMMAND_INIT=AT&F COMMAND_INIT=ATX1 &B49 \\S1 S2=128 COMMAND_INIT=AT COMMAND_DIAL=ATD COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT /V.110 CONNECT_EC=CONNECT /X.75 [EEH Elink 29-3 ISDN - GER] ALIAS=EEH Elink 310 - GER DETECT_STRING=ATI DETECT_RESPONSE=Elink 29-3 [EEH Elink 32-3 ISDN - GER] ALIAS=EEH Elink 310 - GER DETECT_STRING=ATI DETECT_RESPONSE=Elink 32-3 ;---------------------------------------- ;Elsa Modems (Germany) ;---------------------------------------- [ELSA MicroLink 2440T - GER] =\\Q0 =\\Q3 =\\N0 =\\N3 =%C0 =%C3 =M0 =M1 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=19200 COMMAND_INIT=AT&F$K0 X3 S0=0 S2=128 S7=55 S95=8\\V1 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL DETECT_STRING=ATI6 DETECT_RESPONSE=MicroLink 2440T ;---------------------------------------- [ELSA MicroLink 2440TR - GER] ALIAS=ELSA MicroLink 2440T - GER DETECT_STRING=ATI6 DETECT_RESPONSE=MicroLink 2440TR ;---------------------------------------- [ELSA MicroLink 2460TL - GER] =\\Q0 =\\Q3 =\\N0 =\\N3 =%C0 =%C3 =M0 =M1 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=19200 COMMAND_INIT=AT&F$K0 X3 S0=0 S2=128 S7=55 S95=8\\V1 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL DETECT_STRING=ATI6 DETECT_RESPONSE=MicroLink 2460TL ;---------------------------------------- [ELSA MicroLink 2460PC - GER] ALIAS=ELSA MicroLink 2460TL - GER DETECT_STRING=ATI6 DETECT_RESPONSE=MicroLink 2460TL ;---------------------------------------- [ELSA MicroLink 2460MC - GER] ALIAS=ELSA MicroLink 2460TL - GER DETECT_STRING=ATI6 DETECT_RESPONSE=MicroLink 2460MC ;---------------------------------------- [ELSA MicroLink 14.4 PC - GER] =\\Q0 =\\Q3 =\\N0 =\\N3 =%C0 =%C3 =M0 =M1 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 DETECT_STRING=ATI6 DETECT_RESPONSE=MicroLink 14.4PC COMMAND_INIT=AT&F$K0 X3 S31=64 S0=0 S2=128 S7=55 S95=8\\V1 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL ;---------------------------------------- [ELSA MicroLink 14.4 TL - GER] ALIAS=ELSA MicroLink 14.4 PC - GER DETECT_STRING=ATI6 DETECT_RESPONSE=MicroLink 14.4TL ;---------------------------------------- [ELSA MicroLink 14.4 T - GER] ALIAS=ELSA MicroLink 14.4 PC - GER DETECT_STRING=ATI6 DETECT_RESPONSE=MicroLink 14.4T ;---------------------------------------- [ELSA MicroLink 14.4 TM - GER] ALIAS=ELSA MicroLink 14.4 PC - GER DETECT_STRING=ATI6 DETECT_RESPONSE=MicroLink 14.4TM ;---------------------------------------- [ELISA 144 - GER] ALIAS=ELSA MicroLink 14.4 PC - GER DETECT_STRING=ATI6 DETECT_RESPONSE=ELISA 144 ;---------------------------------------- [ELSA MicroLink 288ooTL - GER] =\\Q0 =\\Q3 =\\N0 =\\N3 =%C0 =%C3 =M0 =M1 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=28800 MAXCONNECTBPS=115200 COMMAND_INIT=AT&F$K0 X3 S0=0 S2=128 S7=55 S31=64 S95=8\\V1 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL DETECT_STRING=ATI6 DETECT_RESPONSE=MicroLink 288ooTL ;---------------------------------------- [ELSA MicroLink 14.4MC - GER] DEVICETYPE=modem CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =M1 =M0 =&K3 =&K0 =\\N3 =\\N0 =%C3 =%C0 =ATDT =ATX3D COMMAND_INIT=AT&F&C1&D2 X3 W2 \\J0 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL DETECT_STRING=ATI6 DETECT_RESPONSE=MicroLink 14.4MC ;---------------------------------------- [ELSA ZIFF 144 - GER] ALIAS=ELSA MicroLink 14.4MC - GER DETECT_STRING=ATI6 DETECT_RESPONSE=ZIFF 144 ;---------------------------------------- [ELSA MicroLink ISDN/TL - GER] =\\Q0 =\\Q3 =\\N0 =\\N6 =ATD =ATD CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=64000 MAXCONNECTBPS=57600 COMMAND_INIT=AT&FX3 S0=0 S2=128 \\V1 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL COMMAND_DETECT=ATI6 COMMAND_RESPONSE=MicroLink ISDN/TL ;------------------------- ; ICO Innovative - Modems ;------------------------- [Telejet 14400 - GER] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=57600 =M1 =M0 =&K3 =&K =\\N5 =\\N0 =%C3 =%C0 =ATDP =ATD DETECT_STRING=ATI4 DETECT_RESPONSE=TELEJET High Speed FaxModem 14400 COMMAND_INIT=AT&F&D2X1Q0N1 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT ;--------------------------------- ; KE Kommunikations-Elektronik ;--------------------------------- ;---------------------------------------- [LOGEM 914 - GER] CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =M1 =M0 =\\Q2 =\\Q0 =%C1 =%C0 =\\N2 =\\N0 =ATDT =ATD DETECT_STRING=ATI0 DETECT_RESPONSE=Version 3. DETECT_RESPONSE=Version 2.03 COMMAND_INIT=AT&F COMMAND_INIT=AT&C2&D2Q0V1E1X1&I1%C1\\Q2S0=0S2=128 S7=55 COMMAND_INIT=AT COMMAND_DIAL= ;CONNECT=CONNECT ;CONNECT_EC=CONNECT /REL ;CONNECT_EC=CONNECT /COMP COMMAND_LISTEN=ATS0=1 ;CONNECT=CONNECT ;CONNECT_EC=CONNECT /REL ;CONNECT_EC=CONNECT /COMP ;------------------------------------ [LOGEM 928 - GER] ALIAS=LOGEM 914 - GER MAXCARRIERBPS=28800 MAXCONNECTBPS=57600 ;------------------------------------ [ke WorldBlazer - GER] ALIAS=Telebit WorldBlazer DETECT_STRING=ATI3 DETECT_RESPONSE=T3SA-WB-DEU ;---------------------------------------- [Hayes Optima 9600 - GER] ALIAS=Hayes Optima 9600 ;---------------------------------------- [Hayes Optima 14400 - GER] ALIAS=Hayes Optima 14400 ;---------------------------------------- [Hayes Ultra 9600 - GER] ALIAS=Hayes Optima 9600 ;---------------------------------------- [Hayes Ultra 14400 - GER] ALIAS=Hayes Optima 14400 ;---------------------------------------- ;---------------------------------------- ; Streetware Modems ;---------------------------------------- [Holmes 14.4 all models - GER] =M1 =M0 =&K3 =&K0 =%C1 =%C0 =\\N3 =\\N0 =ATX3D =ATD CALLBACKTIME=10 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=57600 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=2 COMMAND_DIAL= ;---------------------------------------- [Telelink IMS08 - GER] =M1 =M0 =&K3 =&K0 =%C1 =%C0 =\\N7 =\\N0 =ATX3D =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=\ Copyright 1993, Telelink Communications Inc.\ IMS-08 FAXLINE REV . (D) CALLBACKTIME=10 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=57600 COMMAND_INIT=AT&F2&C1&D2 V1 S0=0 S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=2 COMMAND_DIAL= ;============================== ; ZyXEL Modems (international) ;============================== [ZyXEL U-1496 Plus] ;Cannot toggle EC and DC entirely independently in ZyXel. =M1 =M0 =&H3 =&H0 =&K3 =&K0 =&K4 = =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=19200 MAXCONNECTBPS=57600 DETECT_STRING=ATI0 DETECT_RESPONSE=U1496S VP DETECT_STRING=ATI1 DETECT_RESPONSE=U1496S VP COMMAND_INIT=AT &F X5 S41.4=1 COMMAND_INIT=AT S2=128 S7=55 COMMAND_INIT=AT COMMAND_LISTEN=ATS0=1 COMMAND_DIAL= ;---------------------------------------- [ZyXEL U-1496E] ALIAS=ZyXEL U-1496 Plus MAXCARRIERBPS=16800 DETECT_STRING=ATI0 DETECT_RESPONSE=U1496E VM DETECT_STRING=ATI1 DETECT_RESPONSE=U1496E VM ;---------------------------------------- [ZyXEL U-1496E Plus] ALIAS=ZyXEL U-1496 Plus DETECT_STRING=ATI0 DETECT_RESPONSE=U1496E VP DETECT_STRING=ATI1 DETECT_RESPONSE=U1496E VP ;---------------------------------------- [ZyXEL U-1496B] ALIAS=ZyXEL U-1496 Plus MAXCARRIERBPS=16800 DETECT_STRING=ATI0 DETECT_RESPONSE=U1496B VM DETECT_STRING=ATI1 DETECT_RESPONSE=U1496B VM ;---------------------------------------- [ZyXEL U-1496B Plus] ALIAS=ZyXEL U-1496 Plus DETECT_STRING=ATI0 DETECT_RESPONSE=U1496B VP DETECT_STRING=ATI1 DETECT_RESPONSE=U1496B VP ;---------------------------------------- [ZyXEL U-1496P] ALIAS=ZyXEL U-1496 Plus MAXCARRIERBPS=16800 DETECT_STRING=ATI1 DETECT_RESPONSE=U1496C VM ;---------------------------------------- [ZyXEL U-1496R] ALIAS=ZyXEL U-1496 Plus MAXCARRIERBPS=16800 DETECT_STRING=ATI1 DETECT_RESPONSE=U1496R VM ;---------------------------------------- [ZyXEL U-1496R Plus] ALIAS=ZyXEL U-1496 Plus DETECT_STRING=ATI1 DETECT_RESPONSE=U1496R VP ;---------------------------------------- [ZyXEL U-1496RN] ALIAS=ZyXEL U-1496 Plus MAXCARRIERBPS=16800 DETECT_STRING=ATI1 DETECT_RESPONSE=U1496RN VM ;---------------------------------------- [ZyXEL U-1496RN plus] ALIAS=ZyXEL U-1496 Plus DETECT_STRING=ATI1 DETECT_RESPONSE=U1496RN VP ;---------------------------------------- [ZyXEL U-1496SN Plus] ALIAS=ZyXEL U-1496 Plus DETECT_STRING=ATI1 DETECT_RESPONSE=U1496SN VP ;---------------------------------------- ; ZyXEL Modems (Germany) ;---------------------------------------- [ZyXEL U-1496G Plus - GER] ALIAS=ZyXEL U-1496 Plus DETECT_STRING=ATI1 DETECT_RESPONSE=U1496G ;---------------------------------------- [ZyXEL U-1496EG Plus - GER] ALIAS=ZyXEL U-1496 Plus DETECT_STRING=ATI1 DETECT_RESPONSE=U1496EG VP ;---------------------------------------- [ZyXEL U-1496EG - GER] ALIAS=ZyXEL U-1496 Plus MAXCARRIERBPS=16800 DETECT_STRING=ATI1 DETECT_RESPONSE=U1496EG VM ;==================================== ;SWISSE-Modems ;==================================== ;------------------------------------ ; Martignoni Electronics AG - Modems ;------------------------------------ [M. Bullet ModemMan - CH] =M1 =M0 =$F4 =$F5 =$C1 =$C0 =$E3 =$E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=57600 DETECT_STRING=ATI1 DETECT_RESPONSE=P1496MX COMMAND_INIT=AT&F&C1&D2 $X1 V1 S0=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [M. Bullet E1414MX - CH] =M1 =M0 =$F4 =$F5 =$C1 =$C0 =$E3 =$E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=57600 DETECT_STRING=ATI1 DETECT_RESPONSE=E1414MX COMMAND_INIT=AT&F&C1&D2 $X1 V1 S0=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [M. Bullet PCMCIA 1414M - CH] =M1 =M0 =$F4 =$F5 =$C1 =$C0 =$E3 =$E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=57600 DETECT_STRING=ATI1 DETECT_RESPONSE=C1414AX COMMAND_INIT=AT&F&C1&D2 $X1 V1 S0=0 X3 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [M. Bullet PC1414MX - CH] =M1 =M0 =$F4 =$F5 =$C1 =$C0 =$E3 =$E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=57600 DETECT_STRING=ATI1 DETECT_RESPONSE=PC1414MX COMMAND_INIT=AT&F&C1&D2 $X1 V1 S0=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [M. Bullet ModemMan V.terbo - CH] =M1 =M0 =$F4 =$F5 =$C1 =$C0 =$E3 =$E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF= MAXCARRIERBPS=19200 MAXCONNECTBPS=57600 DETECT_STRING=ATI1 DETECT_RESPONSE=P192MX COMMAND_INIT=AT&F&C1&D2 $X1 V1 S0=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [M. Bullet PC192MX V.terbo - CH] =M1 =M0 =$F4 =$F5 =$C1 =$C0 =$E3 =$E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF= MAXCARRIERBPS=19200 MAXCONNECTBPS=57600 DETECT_STRING=ATI1 DETECT_RESPONSE=PC192MX COMMAND_INIT=AT&F&C1&D2 $X1 V1 S0=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [M. Bullet 100E V.34 - CH] =M1 =M0 =$F4 =$F5 =$C1 =$C0 =$E3 =$E0 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF= MAXCARRIERBPS=28800 MAXCONNECTBPS=115200 DETECT_STRING=ATI1 DETECT_RESPONSE=BULLET 100E COMMAND_INIT=AT&F&C1&D2 $X1 V1 S0=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [M. CashCom - CH] =M1 =M0 =&K3 =&K0 =%C3 =%&C0 =\\N3 =\\N1 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=57600 DETECT_STRING=ATI4 DETECT_RESPONSE=CashCom COMMAND_INIT=AT&FW0S0=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=2 ;---------------------------------------- [M. SpiderMan - CH] =M1 =M0 =&K3 =&K0 =%C3 =%&C0 =\\N3 =\\N1 =ATDT =ATD CALLBACKTIME=10 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=57600 DETECT_STRING=ATI4 DETECT_RESPONSE=SpiderMan COMMAND_INIT=AT&FW0S0=0 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=2 ;---------------------------------------- ;AUSTRIAN MODEMS ;---------------------------------------- [ZyXEL U-1496A Plus - AUT] ALIAS=ZyXEL U-1496 Plus DETECT_STRING=ATI1 DETECT_RESPONSE=U1496S V.AUST P ;---------------------------------------- [ZyXEL U-1496EA Plus - AUT] ALIAS=ZyXEL U-1496 Plus DETECT_STRING=ATI1 DETECT_RESPONSE=U1496E V.AUST P ;---------------------------------------- [ZyXEL U-1496EA - AUT] ALIAS=ZyXEL U-1496 Plus MAXCARRIERBPS=16800 DETECT_STRING=ATI1 DETECT_RESPONSE=U1496E V.AUST M ;---------------------------------------- [ZyXEL U-1496R Plus - AUT] ALIAS=ZyXEL U-1496 Plus DETECT_STRING=ATI1 DETECT_RESPONSE=U1496R V.AUST P ;---------------------------------------- [ZyXEL U-1496R - AUT] ALIAS=ZyXEL U-1496 Plus MAXCARRIERBPS=16800 DETECT_STRING=ATI1 DETECT_RESPONSE=U1496R V.AUST M ;---------------------------------------- [ZyXEL U-1496RN - AUT] ALIAS=ZyXEL U-1496 Plus MAXCARRIERBPS=16800 DETECT_STRING=ATI1 DETECT_RESPONSE=U1496RN V.AUST M ;---------------------------------------- ; FRENCH MODEMS ;---------------------------------------- [Codex 326x - FRN] ALIAS=Codex 3260 DETECT_STRING=AT&I0 DETECT_RESPONSE=6510 [Codex 326x FAST - FRN] ALIAS=Codex 3260 Fast DETECT_STRING=AT&I0 DETECT_RESPONSE=7061 ;********** BOITIERS KORTEX KXPRO **************** [KORTEX KXPRO 9600 - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 L3 V1 W1N0 X4 S0=0 S2=43 S7=55 S95=34 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ [KORTEX KXPRO 144 POCKET - FRN] alias=KORTEX KXPRO 144 BOX - FRN DETECT_STRING=ATI DETECT_RESPONSE=KORTEX KXPRO 144 [KORTEX NFX 144 POCKET - FRN] alias=KORTEX KXPRO 144 BOX - FRN DETECT_STRING=ATI DETECT_RESPONSE=KORTEX NFX 144 [KORTEX KXPRO 144 BOX - FRN] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0\\G1 =ATDT =ATD DETECT_STRING=ATI DETECT_RESPONSE=KORTEX KXPRO 144 COMMAND_INIT=AT&FL3W0X4S0=2S95=40 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT [KORTEX KXPOCKET 9600 - FRN] alias=KORTEX KXPRO 9600 - FRN [KORTEX KXPRO 2400 - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=ATI DETECT_RESPONSE=KORTEX KXPRO 2400 COMMAND_INIT=AT&F&C1&D2 L3 V1 W1N0 X4 S0=0 S2=43 S7=55 S95=34 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ ; ************** CARTES KORTEX ********************* [KORTEX NFX 144 CARTES - FRN] alias=KORTEX KXPRO 144 CARTES - FRN DETECT_STRING=ATI DETECT_RESPONSE=KORTEX KXPRO 144 [KORTEX KXPRO 144 CARTES - FRN] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=57600 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0\\G1 =ATDT =ATD DETECT_STRING=ATI DETECT_RESPONSE=KORTEX KXPRO 144 COMMAND_INIT=AT&FL3W0X4S0=2S95=40 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT ;******************************** Modems PNB ******************************** [PNB Baby RIO 14400 - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=14400 =M1 =M0 ;= Keep the default value ;= Keep the default value = = =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=43 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 [PNB AMAZONE 2400 - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 =M1 =M0 ;= Keep the default value ;= Keep the default value =\\Q3 =\\Q0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2V1S0=0 S2=43S7=55 \\V1 ;OK=Direct [unbuffered] LinkOK COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT  CONNECT=CONNECT /REL CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT=CONNECT /REL CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 ;******************* Modem Anderson Jacobson CXR *************** [AJ 2423 - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=19200 =M1 =M0 =*LG2 =*LG0 =*E1 =*E0 =*T3 =*M1 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=AJ2423 COMMAND_INIT=AT&F&C1*M2&D0S0=0S2=43S7=55X4V1Q0 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CONNECT /LAPM COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /LAPM CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 [AJ 1445/1446 - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=19200 =M1 =M0 =*LG2 =*LG0 =*E1 =*E0 =*T3 =*M1 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=AJ 1445 DETECT_STRING=ATI3 DETECT_RESPONSE=AJ 1446 COMMAND_INIT=AT&F&C1*M2&D2S0=0S2=43S7=55X4V1Q0 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /LAPM CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /LAPM CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 [AJ 9636 - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=19200 =M1 =M0 =*LG2 =*LG0 =*E1 =*E0 =*T3 =*M1 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=AJ 9636 COMMAND_INIT=AT&F&C1*M2&D2S0=0S2=43S7=55X4V1Q0 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /LAPM CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /LAPM CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 ;******************* Modems L.C.E. ******************************* [LCE 126P - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=4800 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2L3V1W1N0X4S0=0S2=43S7=55S95=34 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ [LCE 132P - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 =M1 =M0 =&K4 =&K0 =Z12 =Z10 =Z12 =Z10 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 L3V1N0Q0S0=0S2=43S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CARRIER \ PROTOCOL V42BIS\ CONNECT CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL V42BIS\ CONNECT ; ********************** Modems 3X ************************** [3X 396D - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=9600 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 S0=0 S2=43 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 [3X 514D - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 S0=0 S2=43 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 [3X WYSIWYF 514DB - FRN] ALIAS=3X - FRN DETECT_STRING=ATI0 DETECT_RESPONSE=3X WYSIWYF 514DB [3X WYSIWYF 514DBX - FRN] ALIAS=3X - FRN DETECT_STRING=ATI0 DETECT_RESPONSE=3X WYSIWYF 514DBX [3X WYSIWYF 514DP - FRN] ALIAS=3X - FRN DETECT_STRING=ATI0 DETECT_RESPONSE=3X WYSIWYF 514DP [3X WYSIWYF 514DPX - FRN] ALIAS=3X - FRN DETECT_STRING=ATI0 DETECT_RESPONSE=3X WYSIWYF 514DPX [3X WYSIWYF 514DS - FRN] ALIAS=3X - FRN DETECT_STRING=ATI0 DETECT_RESPONSE=3X WYSIWYF 514DS [3X WYSIWYF 514DSX - FRN] ALIAS=3X - FRN DETECT_STRING=ATI0 DETECT_RESPONSE=3X WYSIWYF 514DSX [3X WYSIWYF 496DB - FRN] ALIAS=3X - FRN DETECT_STRING=ATI0 DETECT_RESPONSE=3X WYSIWYF 496DB [3X WYSIWYF 496D - FRN] ALIAS=3X - FRN DETECT_STRING=ATI4 DETECT_RESPONSE=496 [3X WYSIWYF 514D - FRN] ALIAS=3X - FRN DETECT_STRING=ATI4 DETECT_RESPONSE=514 [3X - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 S0=0 S2=43 S7=55 X0 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 ; ********** Modems COM1 ************************************************** [COM1 MV214 - FRN] ALIAS=COM1 MV219 - FRN DETECT_STRING=ATI DETECT_RESPONSE= MV214 [COM1 MV215 - FRN] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=9600 =M1 =M0 =&E5 =&E0 =&E2 =&E0 =&E1 =&E0 =ATDT =ATD DETECT_STRING=ATI DETECT_RESPONSE= MV215 COMMAND_INIT=AT&F X4 S0=0 S2=43 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT=CONNECT CONNECT_EC=CONNECT RELIABLE/COMPRESSED CONNECT_EC=CONNECT RELIABLE COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT=CONNECT CONNECT_EC=CONNECT RELIABLE/COMPRESSED CONNECT_EC=CONNECT RELIABLE [COM1 MV216 - FRN] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N7 =\\N0 =ATDT =ATD DETECT_STRING=ATI7 DETECT_RESPONSE=3700 STANDALONE COMMAND_INIT=AT&F &C1 X7 S0=0 S2=43 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42b CONNECT_EC=CONNECT /V42 CONNECT=CONNECT COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /V42b CONNECT_EC=CONNECT /V42 CONNECT=CONNECT [COM1 MV219 - FRN] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=9600 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 ; ne pas activer le V42 si modem MV219 sur le serveur. MNP4 (\N3) OK. =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=ATI DETECT_RESPONSE= MV219 COMMAND_INIT=AT&F X0 S0=2 S2=43 S7=55 S95=40 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=PROTOCOL ALT\ COMPRESSION CLASS 5\ CONNECT COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=PROTOCOL ALT\ COMPRESSION CLASS 5\ CONNECT [COM1 MC215 - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=9600 =M1 =M0 =\\Q3 =\\Q0 ;Problème de connexion si correction et compression activ‚es ;=%C1 ;=%C0 ;=\\N7 ;=\\N0 =ATDT =ATD DETECT_STRING=ATI DETECT_RESPONSE=MC215 COMMAND_INIT=AT&F S0=0 S2=43 S7=55 S95=40 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=PROTOCOL LAP-M\ COMPRESSION V.42bis\ CONNECT COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=PROTOCOL LAP-M\ COMPRESSION V.42bis\ CONNECT [COM1 MC216 - FRN] ALIAS=COM1 MV216 - FRN ;*********** Modems pour portables TOSHIBA ************ [TOSHIBA SLIM ASYNC - FRN] ALIAS=COM1 MV216 - FRN [TOSHIBA SLIM SYNC - FRN] ALIAS= ARN DX - FRN [TOSHIBA SLIM FAX / 2400 - FRN] ALIAS=COM1 MC215 - FRN ; ********** Modems ATTEL ******************* [ATTEL MX 96xxx - FRN] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 =M1 =M0 =\\Q2 =\\Q0 =%C1 =%C0 =\\N6 =\\N0 =ATDT =ATD DETECT_STRING=ATI1 DETECT_RESPONSE=MX 96 COMMAND_INIT=AT:W1&C1&D2 S0=2 S2=43 S7=55 \\V1 \\M0 COMMAND_INIT=AT OK=OK COMMAND_DIAL= CONNECT=CONNECT CONNECT=CONNECT CONNECT=CONNECT TREILLIS COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT=CONNECT CONNECT=CONNECT TREILLIS [ATTEL MX 144_9600bps - FRN] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=9600 =M1 =M0 ;Pas de compression ni correction pour ce modem. =ATDT =ATD COMMAND_INIT=AT:W1&C1&D2 S0=2 S2=43 S7=55 COMMAND_INIT=AT OK=OK COMMAND_DIAL= CONNECT=CONNECT CONNECT=CONNECT CONNECT=CONNECT TREILLIS CONNECT=CONNECT TCM COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT=CONNECT CONNECT=CONNECT TREILLIS CONNECT=CONNECT TCM [ATTEL MX 144_14400bps - FRN] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=14400 =M1 =M0 ;Pas de compression ni correction pour ce modem. =ATDT =ATD COMMAND_INIT=AT:W1&C1&D2 S0=2 S2=43 S7=55 COMMAND_INIT=AT OK=OK COMMAND_DIAL= CONNECT=CONNECT CONNECT=CONNECT CONNECT=CONNECT TREILLIS CONNECT=CONNECT TCM COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT=CONNECT CONNECT=CONNECT TREILLIS CONNECT=CONNECT TCM ;*************************** QUATERNAIRE ********************************** [QUATERNAIRE V32.BIS - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 ;= Keep the default value ;= Keep the default value = = =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=ATI3 DETECT_RESPONSE=Quaternaire COMMAND_INIT=AT&F&C1&D2 V1 X1 S0=0 S2=43 S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 ;******************* Modems SAT ******************************* [SAT 14402 - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 ;=&K3 =&K0 ;=%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=ATI4 DETECT_RESPONSE=TELSAT 14402 ; probl‚me de connexion si 0 compression activ‚e !. COMMAND_INIT=ATF0&C1&D2L3V1W0N0X4S0=2S2=43S7=55S95=34 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ ;***************** Modems GENER ******************** [GENFAX 14400 - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD DETECT_STRING=ATI4 DETECT_RESPONSE=GENFAX144 COMMAND_INIT=AT&F&C1&D2L3V1W0X4N1S0=2S2=43S7=55S95=40 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT [GENER GE925 - FRN] CALLBACKTIME=45 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =\\Q3 =\\Q0 =\\N3 =\\N0 =%C1 =%C0 =ATDT =ATD ;DETECT_STRING=MP ;DETECT_RESPONSE=GE 925 COMMAND_INIT=AT&FV1&I2X4N1\\V1S0=2S2=43S7=55 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL 5 CONNECT_EC=CONNECT /REL 4 CONNECT_EC=CONNECT /REL LAPM CONNECT_EC=CONNECT /REL LAPM COMP COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /REL 5 CONNECT_EC=CONNECT /REL 4 CONNECT_EC=CONNECT /REL LAPM CONNECT_EC=CONNEC/REL LAPM COMP [GENER - Generique 14400 - FRN] ;[GENER - G‚n‚rique 14400 - FRN] ;setup doesn't process extended characters in modem names - ramc ;Script … s‚l‚ctionner si probl‚me de connection avec le GENFAX 14400 uniquement. ; CALLBACKTIME=35 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD ;X0 => Seulement CONNECT de retourn‚. COMMAND_INIT=AT&F&C1&D2L3V1W0X0N1S0=2S2=43S7=55S95=40 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 ;******************************* Modems ARN ************************* [ARN DX - FRN] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0\\G1 =ATDT =ATD DETECT_STRING=ATI5 DETECT_RESPONSE=ARNDX COMMAND_INIT=AT&FL3W0X4S0=2S95=40 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: ALT - CELLULAR\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: ALT - CELLULAR\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: ALT - CELLULAR\ COMPRESSION: NONE\ CONNECT CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ CONNECT_EC=PROTOCOL: ALT - CELLULAR\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: ALT - CELLULAR\ COMPRESSION: NONE\ CONNECT CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT [ARN Generique - FRN] ;[ARN G‚n‚rique - FRN] ; setup doesn't process extended chars in modem names - ram ;Recommand‚ pour le serveur. CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0\\G1 =ATDT =ATD DETECT_STRING=ATI5 DETECT_RESPONSE=ARNDX COMMAND_INIT=AT&FL3W0X0S0=2S95=40 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 ;******************************************** Modems PIAL ********************* [PIAL FAXMOD PC - FRN] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0\\G1 =ATDT =ATD DETECT_STRING=ATI4 DETECT_RESPONSE=PIAL FAXMOD PC COMMAND_INIT=AT&FL3W0X4S0=2S95=40 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: ALT\ COMPRESSION: NONE\ CONNECT CONNECT_EC=PROTOCOL: ALT - CELLULAR\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: ALT - CELLULAR\ COMPRESSION: NONE\ CONNECT CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT COMMAND_LISTEN=ATS0=2 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ CONNECT_EC=PROTOCOL: ALT\ COMPRESSION: NONE\ CONNECT CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: LAP-M\ COMPRESSION: NONE\ CONNECT CONNECT_EC=PROTOCOL: ALT - CELLULAR\ COMPRESSION: V.42BIS\ CONNECT CONNECT_EC=PROTOCOL: ALT - CELLULAR\ COMPRESSION: NONE\ CONNECT ;------------------------------------------------ ; ITALIAN Modems ;------------------------------------------------ ;----------------------------------------- [DATACONSYST DAC124 - ITA] ALIAS=Octocom 8324 ;---------------------------------------- [SYSNET SMF-04 - ITA] =&K0 =&K3 =\\N0 =\\N3 =%C0 =%C1 =M0 =M1 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=19200 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 W1 S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;----------------------------------------- [SYSNET SMF-36 - ITA] =&K0 =&K3 =\\N0 =\\N3 =%C0 =%C1 =M0 =M1 =ATDT =ATD CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=19200 COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 W1 S95=44 COMMAND_INIT=AT COMMAND_DIAL= COMMAND_LISTEN=ATS0=1 ;---------------------------------------- [CDC 6438 - ITA] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 L3 V1 W1N0 X4 S0=0 S2=43 S7=55 S95=34 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ [CDC 6436 - ITA] CALLBACKTIME=30 DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=2400 =M1 =M0 =&K3 =&K0 =%C3 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 W1N0 X4 S0=0 S2=43 S7=55 S95=34 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /V42 CONNECT_EC=CONNECT /V42BIS CONNECT_EC=CONNECT /MNP5 CONNECT_EC=CONNECT /MNP4 CONNECT_EC=CARRIER \ PROTOCOL: LAP-M\ COMPRESSION: V.42BIS\ CONNECT /ARQ [DIGICOM SNM28 - ITA] CALLBACKTIME=30 DEFAULTOFF=compression MAXCARRIERBPS=2400 MAXCONNECTBPS=9600 =M1 =M0 =\\Q3 =\\Q0 =%C1 =%C0 =\\N3 =\\N0 =ATDT =ATD COMMAND_INIT=AT&F&C1&D2 V1 W1 Q0 S7=55 COMMAND_INIT=AT S2=128 S0=0 COMMAND_INIT=AT COMMAND_DIAL= CONNECT=CONNECT CONNECT_EC=CONNECT /REL CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ COMPRESSION: NONE\ CONNECT /REL CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ COMPRESSION: CLASS 5\ CONNECT /REL COMMAND_LISTEN=ATS0=1 CONNECT=CONNECT CONNECT_EC=CONNECT /REL CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ COMPRESSION: NONE\ CONNECT /REL CONNECT_EC=\ CARRIER \ PROTOCOL: ALT\ COMPRESSION: CLASS 5\ CONNECT /REL ;----------------------------------------------- ; Other intl modems: Dutch ;----------------------------------------------- [Tornado 2400] ALIAS=Hayes Compatible 2400 [Tornado 96] ALIAS=GVC SM96 - SWE [Tornado FM14400] ALIAS=GVC FM14400 - SWE