DOCUMENT:Q148425 08-AUG-2001 [winnt] TITLE :Duplexed Mirror Generation Fails with Insufficient Space PRODUCT :Microsoft Windows NT PROD/VER:WinNT:4.0 OPER/SYS: KEYWORDS:kbnetwork ====================================================================== ------------------------------------------------------------------------------- The information in this article applies to: - Microsoft Windows NT Server version 4.0 ------------------------------------------------------------------------------- SYMPTOMS ======== When you use duplexed SCSI controllers and a software mirror of either the operating system partition or a data partition, you may receive the message "Insufficient space on drive X" where X is the target drive or partition. This can happen when using identical controllers and drives. CAUSE ===== When two SCSI controllers are used, the drive geometry is calculated differently for controllers that have BIOS enabled and the identical controller with BIOS disabled. With a controller that has BIOS enabled, the operating system can query the controller BIOS for drive geometry. The BIOS returns a generic drive geometry translation. This translation will have a cylinder count of less than 1,024 to work with MS-DOS. The number of heads is normally increased to arrive at a correct overall size. Because the second controller does not have BIOS enabled, all it can provide the operating system is the size of a block (sector size) and the total number of blocks on the device. Windows NT then uses a default translation of 32 tracks per cylinder, 64 heads and adjusts the number of cylinders to arrive at a correct approximate size. Because of the different translations, cylinder boundaries will be in different places on the drives. This often results in a drive's free space being 1 or 2 MB different on the two identical drives. Internally, Windows NT uses a LARGE_INTEGER (64-bit) number for the number of cylinders and is not constrained by MS-DOS or partition table limitations. RESOLUTION ========== To work around this problem, perform one of the following: - If the SCSI controller supports it, set the translation mode on the primary controller to 32 sectors per track and 64 heads. - Disable the BIOS on the primary controller, and enable it on the secondary controller. Because creating a mirror does not mirror the master boot record, it may also be necessary to set the active partition byte on the new boot drive with MS-DOS Fdisk.exe or with a sector editor. An alternative is to boot the computer from a Windows NT boot floppy disk. Information on how to create this disk can be found in the Windows NT Resource Kit and the Concepts and Planning Guide. STATUS ====== Microsoft has confirmed this to be a problem in Windows NT SUR version 4.0. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available. Additional query words: prodnt ====================================================================== Keywords : kbnetwork Technology : kbWinNTsearch kbWinNT400search kbWinNTSsearch kbWinNTS400search kbWinNTS400 Version : WinNT:4.0 Issue type : kbbug ============================================================================= THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY. Copyright Microsoft Corporation 2001.