DOCUMENT:Q130781 06-FEB-2002 [winnt] TITLE :Trust Fails if PDC Computer Name Exists in a Trusted Domain PRODUCT :Microsoft Windows NT PROD/VER::3.1,3.5,3.51,4.0 OPER/SYS: KEYWORDS: ====================================================================== ------------------------------------------------------------------------------- The information in this article applies to: - Microsoft Windows NT Advanced Server, version 3.1 - Microsoft Windows NT Server versions 3.5, 3.51, 4.0 ------------------------------------------------------------------------------- SYMPTOMS ======== Your two-way trust between Domain1 and Domain2 may experience a failure in one direction. Domain1 may receive the following error message in Event Viewer: Event ID : 5770 Source : NetLogon Description: The session setup to the Windows NT Comain Controller from computer using account failed. is declared to be a BDC in domain . However, tried to connect as either a DC in a trusted domain, a member workstation in domain , or as a server in domain . Use the Server Manager to remove the BDC account for . where PDCx is the primary domain controller of Domainx and BDC is backup domain controller. When you attempt to connect to the PDC of Domain2, you may receive the following error message: The trust relationship between the primary domain and the trusted domain failed. CAUSE ===== User Manager on the Domain1 PDC incorrectly assumes that the Domain2 PDC is a Backup Domain Controller in Domain1 and sends a validation request to it to verify its Security Accounts Management (SAM) database. When the Domain2 PDC attempts to connect as a PDC, the validation request fails. RESOLUTION ========== In NT 3.1: Go to Server Manager and delete the duplicate computer name from the list of servers. This BDC will need to be re-installed if it will be brought up on the network. Or, the PDC can be re-installed that has the duplicate name. In NT 3.5x / 4.0 : If the BDC that is duplicated has been taken off the network, simply delete the duplicate computer account from Server Manager on DOM1. If the BDC and PDC need to coexist, the PDC (or BDC) can be renamed and rebooted. The coinciding entry from Server Manager must also be removed as a result. STATUS ====== Microsoft has confirmed this to be a problem in Windows NT. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available. Additional query words: ====================================================================== Keywords : Technology : kbWinNTsearch kbWinNT351search kbWinNT350search kbWinNT400search kbWinNTSsearch kbWinNTS400search kbWinNTS400 kbWinNTS351 kbWinNTS350 kbWinNTAdvSerSearch kbWinNTAdvServ310 kbWinNTS351search kbWinNTS350search kbWinNT310Search Version : :3.1,3.5,3.51,4.0 ============================================================================= THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY. Copyright Microsoft Corporation 2002.