DOCUMENT:Q123170 05-FEB-2002 [winnt] TITLE :WINS Event Log IDs 4135 - 4144 (Warning Messages) PRODUCT :Microsoft Windows NT PROD/VER::3.5 OPER/SYS: KEYWORDS:kbnetwork ====================================================================== ------------------------------------------------------------------------------- The information in this article applies to: - Microsoft Windows NT Server version 3.5 ------------------------------------------------------------------------------- This article describes WINS event log IDs 4135 through 4144. These events represent warning messages. Event Log IDs 4135 - 4144 ------------------------- Event Description ----- ----------- 4135 The local WINS server received a request from a remote WINS server that is not of the same version. Because the WINS servers are not compatible, the connection was terminated. The version number of the remote WINS server is given below. 4136 Winsock Send could not send all the bytes. Connection could have been aborted by the remote client. 4137 WINS adjusted a scavenging related time interval (%1) so that it is compatible with the replication time intervals. 4138 WINS adjusted a scavenging related time interval (%1). 4139 The timeout period has expired on a call to another WINS server. Assuming that the network and routers are working properly, either the remote WINS server is overloaded, or its TCP listener thread has terminated. 4140 The Scavenger thread found active replicas that needed to be verified with the owner WINS server since they were older than the verify time interval. The table of owner to address mappings indicated the WINS server to be not ACTIVE. 4141 The name registration packet that was just received has too many addresses. The maximum number of addresses for a multi-homed client is 25. The number of addresses found in the packet is given below. 4142 A replica clashed with a static record in the database. The replica was rejected. 4143 WINS could not initialize because of some problem with the RPC service. Make sure that the RPC service is running. 4144 WINS did not send a notification message to the WINS server whose address is given below, because it had a number of communications failures with that server in the past few minutes. Additional query words: NBT NETBT ====================================================================== Keywords : kbnetwork Technology : kbWinNTsearch kbWinNT350search kbWinNTSsearch kbWinNTS350 kbWinNTS350search Version : :3.5 Issue type : kbinfo ============================================================================= THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY. Copyright Microsoft Corporation 2002.