DOCUMENT:Q107726 15-JUN-2001 [sna] TITLE :SNA Server Event 553 Running Novell Requestor for Windows NT PRODUCT :Microsoft SNA Server PROD/VER:WINDOWS:2.0,2.1,2.11 OPER/SYS: KEYWORDS:kbinterop kbnetwork ====================================================================== ------------------------------------------------------------------------------- The information in this article applies to: - Microsoft SNA Server, versions 2.0, 2.1, 2.11, on platform(s): - the operating system: Microsoft Windows NT ------------------------------------------------------------------------------- SYMPTOMS ======== SNA Server Admin hangs on startup and the SnaBase service encounters the following error if Windows NT is installed with the Novell NetWare Requestor for Windows NT, version 1.01: Event 567: Creation of named pipe failed, rc = 10048 Event 624: Creating dump file c:\sna\traces\SNADUMP.LOG for SNABASE.EXE CAUSE ===== The SnaBase service attempts to open the same socket number on both IPX and SPX, although the Novell IPX/SPX driver for Windows NT does not allow this, returning socket error 10048 which means the address is already in use. Event 624 is logged to indicate that an unrecoverable error detected by SnaBase. RESOLUTION ========== An update to SNA Server 2.11 corrects this problem by supporting the ability to configure the SPX port number used by the SnaBase service. Microsoft has updated the following files to correct this problem: On the server and Windows NT clients: \SYSTEM\SNANW.DLL Windows 95 clients: \SYSTEM\SNACNW.DLL Windows 3.x clients: \SYSTEM\NWCLI.DLL To configure the SPX port number, install the new file and add the following registry value on the server under the HKEY_LOCAL_MACHINE subtree under the following subkey: /SYSTEM/CurrentControlSet/Services/SnaBase/ Parameters/SnaSpx Value Name: SnaBasePort Data Type: REG_DWORD Data: is the port number in hexadecimal. This number must not match the default of 0x84C8. When this parameter is specified the SnaBase uses the new port number for client "sponsor" connections over SPX. The default port number (0x84C8, or 33992 in decimal) is still used for server to server (IPX) communication. This fix requires an update to all clients (except MS-DOS based clients) because the clients assume that the SnaBase SPX port is always 0x84C8. However, there is no client-side entry required because the server port number is found dynamically through the Netware bindery. STATUS ====== Microsoft has confirmed this to be a problem in SNA Server for Windows NT. This problem was corrected in the latest SNA Server for Windows NT, 2.11 U.S. Service Pack. For information on obtaining the Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces): S E R V P A C K Additional query words: prodsna ====================================================================== Keywords : kbinterop kbnetwork Technology : kbAudDeveloper kbSNAServSearch Version : WINDOWS:2.0,2.1,2.11 Issue type : kbbug ============================================================================= THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY. Copyright Microsoft Corporation 2001.