TITLE: Adding a TruCluster node using clu_add_member does not propagate OpenView Operations (OVO) Agents properly. New Kit Date: 25-JUN-2003 Modification Date: Not Applicable Modification Type: New Kit Copyright (c) Hewlett-Packard Company 2003. All rights reserved. PRODUCT: HP TruCluster Server [R] 5.1 SOURCE: Hewlett-Packard Company ECO INFORMATION: ECO Name: TCV51B20-C0037101-18805-E-20030605 ECO Kit Approximate Size: 2.61MB Kit Applies To: HP TruCluster Server 5.1 PK6 (BL20) ECO Kit CHECKSUMS: /usr/bin/sum results: 29257 2670 /usr/bin/cksum results: 2873287760 2734080 MD5 results: 1effe33a66bed1678501bf9a4bac6e59 SHA1 results: 040f7170224102b0bbf3351f5b3b19a8f844d2c9 ECO KIT SUMMARY: A dupatch-based, Early Release Patch kit exists for HP TruCluster Server 5.1 that contains solutions to the following problem(s): This patch provides an updated version of the clu_add_member command. If the OVO Agent software has been installed on a Trucluster, this patch must be applied before adding the new node to the cluster. Once the patch is installed, adding a member to the cluster will correctly propagate the OVO agents onto to the newly added node. The Patch Kit Installation Instructions and the Patch Summary and Release Notes documents provide patch kit installation and removal instructions and a summary of each patch. Please read these documents prior to installing patches on your system. INSTALLATION NOTES: 1) Install this kit with the dupatch utility that is included in the patch kit. You may need to baseline your system if you have manually changed system files on your system. The dupatch utility provides the baselining capability. 2) The patch in this ERP kit does not have any file intersections with any other ERP available at this time for this product version. 3) This ERP kit will NOT install over any Customer Specific Patches (CSPs) which have file intersections with this ERP kit. Contact your normal Service Provider for assistance if the installation of this ERP kit is blocked by any of your installed CSPs. INSTALLATION PREREQUISITES: You must have installed HP TruCluster Server 5.1 PK6 (BL20) prior to installing this Early Release Patch Kit. KNOWN PROBLEMS WITH THE PATCH KIT: None. RELEASE NOTES FOR TCV51B20-C0037101-18805-E-20030605: Release Notes This document summarizes the contents and special instructions for the TruCluster Server V5.1 patches contained in this kit. For information about installing or removing patches, baselining, and general patch management, see the Patch Kit Installation Instructions document. 1 Release Notes This Early Release Patch Kit Distribution contains: - fixes that resolve the problem(s) reported in: o 221-2-237 * for TruCluster Server V5.1 T64V51B20AS0006-20030210.tar (BL20) The patches in this kit are being released early for general customer use. Refer to the Release Notes for a summary of each patch and installation prerequisites. Patches in this kit are installed by running dupatch from the directory in which the kit was untarred. For example, as root on the target system: > mkdir -p /tmp/CSPkit1 > cd /tmp/CSPkit1 > > tar -xpvf DUV40D13-C0044900-1285-20000328.tar > cd patch_kit > ./dupatch 2 Special Instructions SPECIAL INSTRUCTIONS for TruCluster Server V5.1 Patch C371.01 Add new cluster member after installing this Patch 3 Summary of CSPatches contained in this kit TruCluster Server V5.1 PatchId Summary Of Fix ---------------------------------------- C371.01 clu_add_member does not propagate OVO Agents properly 4 Additional information from Engineering None 5 Affected system files This patch delivers the following files: TruCluster Server V5.1 Patch C371.01 ./usr/sbin/clu_add_member CHECKSUM: 59052 34 SUBSET: TCRBASE510 [R] UNIX is a registered trademark in the United States and other countries licensed exclusively through X/Open Company Limited. Copyright Hewlett-Packard Company 2003. All Rights reserved. This software is proprietary to and embodies the confidential technology of Hewlett-Packard Company. Possession, use, or copying of this software and media is authorized only pursuant to a valid written license from Hewlett-Packard or an authorized sublicensor. This ECO has not been through an exhaustive field test process. Due to the experimental stage of this ECO/workaround, Hewlett-Packard makes no representations regarding its use or performance. The customer shall have the sole responsibility for adequate protection and back-up data used in conjunction with this ECO/workaround.