TITLE: Tru64 UNIX 5.1A ERP for Stale CFS data and AdvFS v3 domain errors Copyright (c) Compaq Computer Corporation 2002. All rights reserved. PRODUCT: Tru64 UNIX [R] 5.1A SOURCE: Compaq Computer Corporation ECO INFORMATION: ECO Name: TCV51ABssb-C0000901-13435-E-20020228 ECO Kit Approximate Size: 5.5MB Kit Applies To: Tru64 UNIX 5.1A with No Patch Kits Applied ECO Kit CHECKSUMS: /usr/bin/sum results: 44283 5340 /usr/bin/cksum results: 1953083994 5468160 MD5 results: 09345a355cbc1cead5344ba886829b8b SHA1 results: 6a9326f4d054f391bc838bfe1ae89ef6a3706442 ECO KIT SUMMARY: A dupatch-based, Early Release Patch kit exists for Tru64 UNIX 5.1A that contains solutions to the following problems: 1) Potential data inconsistency that may occur when a Cluster File System (CFS) client reads a file that was recently written to. Stale data may be returned to the client. 2) Multi-volume AdvFS v3 domains exhibit EIO errors not attributable to hardware. More information can be found in the service notification titled "Tru64 UNIX Stale CFS data and AdvFS v3 domain errors" available from the Compaq Support Reference Library for Tru64 UNIX. The Patch Kit Installation Instructions and the Patch Summary and Release Notes documents provide patch kit installation and removal instructions and a summary of each patch. Please read these documents prior to installing patches on your system. The patches in this ERP kit will also be available in the next mainstream patch kit - Tru64 UNIX 5.1A Patch Kit 2. INSTALLATION NOTES: Install this kit with the dupatch utility that is included in the patch kit. You may need to baseline your system if you have manually changed system files on your system. The dupatch utility provides the baselining capability. INSTALLATION PREREQUISITES: You must have installed Tru64 UNIX 5.1A with No Patch Kits Applied prior to installing this Early Release Patch Kit. KNOWN PROBLEMS WITH THE PATCH KIT: None. RELEASE NOTES FOR TCV51ABssb-C0000901-13435-E-20020228: 1 Release Notes This Early Release Patch Kit Distribution contains: - fixes that resolve the problem(s) reported in: o IHB_0001 IHB_0003 The patches in this kit are being released early for general customer use. Refer to the Release Notes for a summary of each patch and installation prerequisites. Patches in this kit are installed by running dupatch from the directory in which the kit was untarred. For example, as root on the target system: > mkdir -p /tmp/CSPkit1 > cd /tmp/CSPkit1 > > tar -xpvf DUV40D13-C0044900-1285-20000328.tar > cd patch_kit > ./dupatch 2 Special Instructions There are no special instructions for TruCluster Server V5.1A Patch C9.01 There are no special instructions for Tru64 UNIX V5.1A Patch C91.02 3 Summary of CSPatches contained in this kit TruCluster Server V5.1A PatchId Summary Of Fix ---------------------------------------- C9.01 Fix advfs possible stale data Tru64 UNIX V5.1A PatchId Summary Of Fix ---------------------------------------- C91.02 Fix advfs possible stale data and v3 domain errors 4 Additional information from Engineering None 5 Affected system files This patch delivers the following files: TruCluster Server V5.1A Patch C9.01 ./usr/opt/TruCluster/sys/cfs.mod CHECKSUM: 12396 1368 SUBSET: TCRBASE520 ./usr/opt/TruCluster/sys/clubase.mod CHECKSUM: 08450 759 SUBSET: TCRBASE520 ./usr/opt/TruCluster/sys/cms.mod CHECKSUM: 12082 797 SUBSET: TCRBASE520 ./usr/opt/TruCluster/sys/token.mod CHECKSUM: 64533 623 SUBSET: TCRBASE520 Tru64 UNIX V5.1A Patch C91.02 ./sys/BINARY/advfs.mod CHECKSUM: 60453 1271 SUBSET: OSFADVFSBIN520 [R] UNIX is a registered trademark in the United States and other countries licensed exclusively through X/Open Company Limited. Copyright Compaq Computer Corporation 2002. All Rights reserved. This software is proprietary to and embodies the confidential technology of Compaq Computer Corporation. Possession, use, or copying of this software and media is authorized only pursuant to a valid written license from Compaq or an authorized sublicensor. This ECO has not been through an exhaustive field test process. Due to the experimental stage of this ECO/workaround, Compaq makes no representations regarding its use or performance. The customer shall have the sole responsibility for adequate protection and back-up data used in conjunction with this ECO/workaround.