TITLE: HP Tru64 UNIX - 5.1A PK6 Virtual Memory Fixes Copyright (c) Hewlett-Packard Company 2007. All rights reserved. PRODUCT: HP Tru64 UNIX [R] V5.1A SOURCE: Hewlett-Packard Company ECO INFORMATION: ECO Name: T64KIT1001141-V51AB24-E-20070302 ECO Kit Approximate Size: 3.62MB Kit Applies To: HP Tru64 UNIX V5.1A PK6 (BL24) ECO Kit CHECKSUMS: /usr/bin/sum results: 39287 3710 /usr/bin/cksum results: 771326859 3799040 MD5 results: 24766552a3bc1cbcfa70ad8050f613cd SHA1 results: 630ed6f3206dee31bc2ea27af3fa4ce0b1dccc6a ECO KIT SUMMARY: A dupatch-based, Early Release Patch kit exists for HP Tru64 UNIX V5.1A that contains solutions to the following problem(s): The Early Release Patch (ERP) kit announced in this Engineering Advisory provides several virtual memory-related fixes reported in HP Tru64 UNIX v 5.1A PK6. The Patch Kit Installation Instructions and the Patch Summary and Release Notes documents provide patch kit installation and removal instructions and a summary of each patch. Please read these documents prior to installing patches on your system. INSTALLATION NOTES: 1) Install this kit with the dupatch utility that is included in the patch kit. You may need to baseline your system if you have manually changed system files on your system. The dupatch utility provides the baselining capability. 2) The patch in this ERP kit does not have any file intersections with any other ERP available at this time for this product version. 3) This ERP kit will NOT install over any Customer Specific Patches (CSPs) which have file intersections with this ERP kit. Contact your normal Service Provider for assistance if the installation of this ERP kit is blocked by any of your installed CSPs. INSTALLATION PREREQUISITES: You must have installed HP Tru64 UNIX V5.1A PK6 (BL24) prior to installing this Early Release Patch Kit. SUPERSEDE INFORMATION: None KNOWN PROBLEMS WITH THE PATCH KIT: None. RELEASE NOTES FOR T64KIT1001141-V51AB24-E-20070302: Release Notes This document summarizes the contents and special instructions for the Tru64 UNIX V5.1A patches contained in this kit. For information about installing or removing patches, baselining, and general patch management, see the Patch Kit Installation Instructions document. 1 Release Notes This Early Release Patch Kit Distribution contains: - fixes that resolve the problem(s) reported in: o 19082 19182 19283 19290 19415 * for Tru64 UNIX V5.1A T64V51AB24AS0006-20031031.tar (BL24) This kit includes a patch which requires system reboot. The patches in this kit are being released early for general customer use. Refer to the Release Notes for a summary of each patch and installation prerequisites. Patches in this kit are installed by running dupatch from the directory in which the kit was untarred. For example, as root on the target system: > mkdir -p /tmp/CSPkit1 > cd /tmp/CSPkit1 > > tar -xpvf DUV40D13-C0044900-1285-20000328.tar > cd patch_kit > ./dupatch 2 Special Instructions SPECIAL INSTRUCTIONS for Tru64 UNIX V5.1A Patch C1798.00 3 Summary of CSPatches contained in this kit Tru64 UNIX V5.1A PatchId Summary Of Fix ---------------------------------------- C1798.00 Fixes to Wiring code, _OtsMove and UBC 4 Additional information from Engineering None 5 Affected system files This patch delivers the following files: Tru64 UNIX V5.1A Patch C1798.00 ./sys/BINARY/arch_alphapmap.mod CHECKSUM: 04079 302 SUBSET: OSFHWBIN520 ./sys/BINARY/generic.mod CHECKSUM: 31096 10 SUBSET: OSFBIN520 ./sys/BINARY/vm.mod CHECKSUM: 12840 521 SUBSET: OSFBIN520 [R] UNIX is a registered trademark in the United States and other countries licensed exclusively through X/Open Company Limited. Copyright Hewlett-Packard Company 2007. All Rights reserved. This software is proprietary to and embodies the confidential technology of Hewlett-Packard Company. Possession, use, or copying of this software and media is authorized only pursuant to a valid written license from Hewlett-Packard or an authorized sublicensor. This ECO has not been through an exhaustive field test process. Due to the experimental stage of this ECO/workaround, Hewlett-Packard makes no representations regarding its use or performance. The customer shall have the sole responsibility for adequate protection and back-up data used in conjunction with this ECO/workaround.