TITLE: HP Tru64 UNIX Potential BIND Security Vulnerabilities New Kit Date: 18-FEB-2003 Modification Date: Not Applicable Modification Type: NEW KIT Copyright (c) Hewlett-Packard Company 2002. All rights reserved. PRODUCT: Tru64 UNIX [R] 5.0A SOURCE: Hewlett-Packard Company ECO INFORMATION: ECO Name: T64V50AB17-C0031104-16655-ES-20030129 ECO Kit Approximate Size: 2.1 MB Kit Applies To: Tru64 UNIX 5.0A PK3 (BL17) ECO Kit CHECKSUMS: /usr/bin/sum results: 55843 2090 /usr/bin/cksum results: 143264549 2140160 MD5 results: 7d51a49fc9d9f9692e82b5268a539884 SHA1 results: 3f89d4f7b4ae0fb82c90db742fa66704afd9cabe ECO KIT SUMMARY: A dupatch-based, Early Release Patch kit exists for Tru64 UNIX 5.0A that contains solutions to the following problem(s): Potential BIND (Berkeley Internet Name Domain) security vulnerabilities have been reported to HP that may result in buffer overflows, unauthorized access, or denial of service (DoS) on HP Tru64 UNIX systems. These potential security vulnerabilities may be in the form of local and remote security domain risks. The following potential security vulnerabilities have been corrected: SSRT2408 BIND - (Severity - High) SSRT2410 BIND - (Severity - High) SSRT2411 BIND - (Severity - High) The Patch Kit Installation Instructions and the Patch Summary and Release Notes documents provide patch kit installation and removal instructions and a summary of each patch. Please read these documents prior to installing patches on your system. INSTALLATION NOTES: 1) Install this kit with the dupatch utility that is included in the patch kit. You may need to baseline your system if you have manually changed system files on your system. The dupatch utility provides the baselining capability. 2) The integrated ERP kits provided in this EA contain the corrections from SSRT1-68u and SSRT1-69u, and can be installed by customers who have or have not installed the SSRT1-68u and SSRT1-69u ERP. The kits indicated in this EA are built so that they will install over the SSRT1-68u and SSRT1-69u corrections. However, installation will be blocked if any other patches have been installed that affect the files delivered in the SSRT1-68u and SSRT1-69u kits. 3) This ERP kit will NOT install over any Customer Specific Patches (CSPs) that have file intersections with this ERP kit. Contact your normal Service Provider for assistance if the installation of this ERP kit is blocked by any of your installed CSPs. INSTALLATION PREREQUISITES: You must have installed Tru64 UNIX 5.0A PK3 (BL17) before installing this Early Release Patch Kit. KNOWN PROBLEMS WITH THE PATCH KIT: None. RELEASE NOTES FOR T64V50AB17-C0031104-16655-ES-20030129: 1 Release Notes This Early Release Patch Kit Distribution contains: - fixes that resolve the problem(s) reported in: o SSRT1-68U SSRT2408 SSRT2410 SSRT2411 for Tru64 UNIX V5.0A T64V50AAS0003-20010523.tar (BL17) The patches in this kit are being released early for general customer use. Refer to the Release Notes for a summary of each patch and installation prerequisites. Patches in this kit are installed by running dupatch from the directory in which the kit was untarred. For example, as root on the target system: > mkdir -p /tmp/CSPkit1 > cd /tmp/CSPkit1 > copy the kit to /tmp/CSPkit1 > tar -xpvf DUV40D13-C0044900-1285-20000328.tar > cd patch_kit > ./dupatch 2 Special Instructions There are no special instructions for Tru64 UNIX V5.0A Patch C311.04 3 Summary of CSPatches contained in this kit Tru64 UNIX V5.0A PatchId Summary Of Fix ---------------------------------------- C311.04 Fix for SSRT2408, SSRT2410, SSRT2411, & SSRT1-68U. 4 Additional information from Engineering None 5 Affected system files This patch delivers the following files: Tru64 UNIX V5.0A Patch C311.04 ./sbin/named CHECKSUM: 14612 396 SUBSET: OSFINET505 ./usr/sbin/named CHECKSUM: 43903 454 SUBSET: OSFINET505 ./usr/sbin/named-xfer CHECKSUM: 56888 140 SUBSET: OSFINET505 [R] UNIX is a registered trademark in the United States and other countries licensed exclusively through X/Open Company Limited. Copyright Hewlett-Packard Company 2002. All Rights reserved. This software is proprietary to and embodies the confidential technology of Hewlett-Packard Company. Possession, use, or copying of this software and media is authorized only pursuant to a valid written license from Hewlett-Packard or an authorized sublicensor. This ECO has not been through an exhaustive field test process. Due to the experimental stage of this ECO/workaround, Hewlett-Packard makes no representations regarding its use or performance. The customer shall have the sole responsibility for adequate protection and back-up data used in conjunction with this ECO/workaround.