PROBLEM: (None) (Patch ID: OSF425-580) ******** Updates sys_check utility to version V111. PROBLEM: (75903) (Patch ID: OSF425-849) ******** This patch provides the following changes to the sys_check utility: o Fixes the ra200info tool from core dumping o Updates the sys_check utility to revision 114 PROBLEM: (75564, 75550) (Patch ID: OSF425-807) ******** This patch provides a new collection information tool used by the sys_check utility. It also fixes the following two problems: o A security hole where a user can become root o Collect can not start at boot time due to incorrectly handling SIGHUP signal PROBLEM: (81295, 81296, 81562, 81563) (PATCH ID: OSF425-1020) ******** This patch fixes following problems with the collect command and it adds sysloging when collect suspends, resumes, or receives a signal. - Collect always returns 0 for tape status, - Collect does not display proper PID and PPID on heavily loaded system, - Collect displays warning msg when a HSG80 controller installed, - Collect does not display proper Net status on heavily used network, - Collect does not align MessageQ data properly when the ID field is large, and - Collect does not compute Usertime and Systemtime correctly for processes whose pids are recycled. PROBLEM: (BCGM4134M, BCPM71NXQ, BRO45678A, BCGM814ON, BCPM51JZ6, 81811, 77292, 79179, N/A) (PATCH ID: OSF425-1016) ******** This patch upgrades sys_check utility to v119 and provides the following changes: - fixes the ra200info tool from core dumping - utilizes Compaq Analyze when available - utilizes storages new cliscript tool in place of hszterm - update asu section PROBLEM: (85366) (PATCH ID: OSF425-1087) ******** On systems with no nfs configured sys_check would generate two spurious errors. PROBLEM: (BCGMA1D6Z) (PATCH ID: OSF425-1060) ******** sys_check is incorrectly evaluating the number of HSG controllers connected to a system, especially in a multipath configuration on v5.0a/V5.1. Doing so causes sys_check to run considerably longer.