PROBLEM: (QAR 45825) (Patch ID: OSF405DX-400001) ******** This patch fixes a problem that causes the X server's colormap entries to be corrupted. The current session's colors may become mixed up. For example, the black may be white, the white may be red, and so on. PROBLEM: (QAR 44365 and 46643) (Patch ID: OSF405DX-400001) ******** This patch fixes a problem in which certain file system percent full values may be displayed incorrectly. The percent full values may not match (by more than 1%) the values displayed by the df command. This is especially true for relatively large file systems and for AdvFS file systems. PROBLEM: (QAR 41445) (Patch ID: OSF405DX-400001) ******** This patch fixes a problem with the dxsysinfo application. For systems that have the System V environment subset installed, dxsysinfo displays the /dev/prf device in its Device Information Area as a tape device and each time Update Devices is selected, another /dev/prf icon is added. PROBLEM: (QAR 44882) (Patch ID: OSF405DX-400001) ******** This patch fixes a problem with the dxsysinfo application. When a user logs out of the CDE session, the child process becomes orphaned and continues to run. PROBLEM: (QAR 40964) (Patch ID: OSF405DX-400001) ******** This patch fixes a problem in which the hard disk icons fail to display in the Device Information Area when the colormap is full or when a black/white screen is used.