DCE-VMS VAXDCE03_014 DCE V1.4 for OpenVMS VAX ECO Summary
TITLE: DCE-VMS VAXDCE03_014 DCE V1.4 for OpenVMS VAX ECO Summary
 
Modification Date:  23-SEP-99
Modification Type:  Updated Kit  Supersedes VAXDCE02_014

NOTE:  An OpenVMS saveset or PCSI installation file is stored
       on the Internet in a self-expanding compressed file.
       The name of the compressed file will be kit_name-dcx_vaxexe
       for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
 
       Once the file is copied to your system, it can be expanded
       by typing RUN compressed_file.  The resultant file will
       be the OpenVMS saveset or PCSI installation file which
       can be used to install the ECO.
 
Copyright (c) Compaq Computer Corporation 1999.  All rights reserved.

PRODUCT:    Distributed Computing Environment (DCE) For OpenVMS VAX

OP/SYS:     OpenVMS VAX

SOURCE:     Compaq Computer Corporation

ECO INFORMATION:

     ECO Kit Name:  VAXDCE03_014
     ECO Kits Superseded by This ECO Kit:  VAXDCE02_014
     ECO Kit Approximate Size:  15336 Blocks
                    Saveset A -   108 Blocks
                    Saveset B - 15228 Blocks

     Kit Applies To:  DCE V1.4
                      OpenVMS VAX V5.5-2, V5.5-2H4, V6.2, V7.1

     System/Cluster Reboot Necessary:  No (See Installation Instructions)

     Installation Rating:   2 - To be installed on all systems running
                                the listed versions of OpenVMS and
                                using the following feature:

                                   This remedial kit contains many Year 2000 
                                   related fixes.  Any customer running DCE 
                                   must install this  kit.


ECO KIT SUMMARY:

An ECO kit exists for DCE V1.4 on OpenVMS VAX V5.5-2, V5.5-2H4, V6.2,
V7.1.  This kit addresses the following problems: 

PROBLEMS ADDRESSED IN VAXDCE03_014 KIT:

     o  Fix memory leaks in DCE DECnet OSI Socket interface image

          DCE daemons and DCE user applications terminate abnormally due
          to  with  page  file  exhaustion.   For  Example, DCE endpoint
          mapper, DCE$RPCD, aborts unexpectedly on systems where  DECnet
          OSI  is a supported DCE protocol.  Examination of the rpcd out
          file shows insufficient dynamic memory errors.

          $ type Dce$Specific:[Var.Rpc.Adm]DCE$RPCD.Out
          (socket) (SOCKET_MEM_ALLOC) *** FATAL ERROR at SOCKMEM.C;1\293 ***
          %SYSTEM-F-INSFMEM, insufficient dynamic memory%CMA-F-EXCCOP, 
          exception raised;
          VMS condition code follows


          Please note, there are still memory management  problems  with
          DCE  when  DCEnet  OSI  as  used  as a transport.  If you site
          requires 24 by 7 operation, it you can disable DECnet OSI as a
          DCE  protocol  if  you  have no application requirement to use
          OSI.

          Installation of the DECthreads kit, ALPTHREADS04_071 is highly
          recommended  on  Alpha V7.1 systems.  Page file leakage of DCE
          process is greatly  reduced  after  the  installation  of  the
          ALPTHREADS04_071 kit.


          o  Work-arounds:

          Disable  DECnet  OSI  as   a   DCE   transport   by   defining
          RPC_SUPPORTED_PROTSEQS  or  by  defining the DECnet OSI socket
          shareable image to null with:

            $Define/Sys/Exec DCE$SOCKSHR_DNET_OSI NL:

     o  Eliminate two zero block files left in the  credentials  cache
        directory after a dce_login followed by a kdestroy.

          When a dce_login is performed, six files are  created  in  the
          credentials                  cache                  directory,
          DCE$SPECIFIC:[VAR.SECURITY.CREDS].    An   example   is    the
          following files:

                 16   029D9101.;2           1-OCT-1998 15:28:18.37
                 17   029D9101.;1           1-OCT-1998 15:28:17.76
                 18   029D9102.;1           1-OCT-1998 15:28:19.27
                 19   029D9200.;1           1-OCT-1998 15:28:19.02
                 20   029D9200.DATA;1       1-OCT-1998 15:28:19.38
                 21   029D9200.NC;1         1-OCT-1998 15:28:19.18


          After a kdestroy, two files remain from  the  original  login.
          In the login example above, the following files are left:

                 16   029D9101.;1           1-OCT-1998 15:28:17.76
                 17   029D9102.;1           1-OCT-1998 15:28:19.27



          DCE uses  UNIX  style  file  processing.   When  creating  the
          initial cache file, 029D9101 in the example above, a version 1
          file   is   created   by    allocate_krb5_info    call    from
          sec_login_pvt_setup_identity.     A    subsequent    call   to
          krb5_cc_initialize opens this file  with  the  requirement  to
          create  a  new  version.  On VMS this creates version 2 of the
          file.

          When sec_login_set_context is called  later  during  login,  a
          similar  problem  happens.   To  create  the CC data file like
          029D9200.DATA;1 in the example  above,  a  temporary  file  is
          used.  The temporary file is created, closed and then reopened
          creating two files (029D9200.;1 and 029D9200.;2).  The  second
          version  of the file is populated with the data and renamed to
          029D9200.DATA.  The first version is left.


     o  Allow dce login password input from a command procedure

          DCE login fails  when  the  input  for  the  password  is  not
          obtained  from  a  terminal.   The  login fails with the error
          below:

          $ rgy_edit
          Current site is: registry server at /.../adu26a_cell/subsys/dce/
          sec/master
          l cell_admin
          -dce-
          login: Credentials cache I/O operation failed XXX Error in input 
          password. Login failed.

          exit
          bye



          VMS DCE implementation of krb5_read_password  routine  allowed
          entry of a password only when the input device was a terminal.
          The VMS specific routine prevents the inputted  password  from
          being echoed at the user terminal.

          The VMS routine prevents the use of  a  command  procedure  to
          input  passwords.  While not a good idea, other implementation
          of dce allow password to be input from scripts.

          o  Work-arounds:

          Perform a DCE_LOGIN  prior  to  using  DCE  utilities.   Limit
          procedures to run only until the current login expires.


     o  Allow the Credentials Cache Cleanup interval to be adjusted.

          Every  one  hour,  the  sec_clientd  daemons   deletes   stale
          credentials  files out of the DCE credentials cache directory.
          If run in debug mode, the daemons deletes the files every five
          minutes.   The  interval is not adjustable.  Changes were made
          to make the interval adjustable  between  5  minutes  and  one
          hour.   The interval cannot be greater than 60 minutes or less
          than 5 minutes.

          To    set     the     interval,     define     the     logical
          FCC_CCACHE_CLEANUP_INTERVAL,  to the number of minutes between
          cache cleanups.  The logical may  be  defined  at  the  system
          level,  or  may  be defined in the sec_clientd startup command
          procedure.  If you change  the  interval  while  the  security
          client  daemon  is running, the new interval will be effective
          after the next credentials cache cleanup.




     o  New version V5.0 of TCP/IP services  for  OpenVMS  will  cause
        configuration failures in DCE setup procedures.

              **** IMPORTANT NOTICE ****

     If you have customized the DCE$SETUP.com at your site,  you  should
     remove  the  DCE$SETUP.com  and DCE$SETUP_UCX.com installed by this
     procedure after installation.   The  site  specific  customizations
     will  need to be made to the new versions of the command procedures
     and installed at a later time

     For  example  if  you  have  increased   DCE   daemon   quotas   in
     DCE$SETUP.COM  for  using MULTINET, you will have to make the quota
     adjustments to the version of DCE$SETUP.COM supplied in this kit.

                  **** END NOTICE ****

          A new version of TCP/IP services for OpenVMS is shipping which
          eliminates  some of the UCX commands used by the DCE$SETUP.COM
          and DCE$SETUP_UCX.COM procedures.



          o  Work-arounds:

          Manually edit the setup files.


     o  Fix  DCE$SETUP  start  of   configure   failures   after   the
        installation of Multinet 4.1 B-X

          Updates to multinet changed  the  BGO  device  characteristics
          breaking old logic checking if multinet was installed.



     o  Fix problem where accounts  created  from  VMS  1.4  and  V1.5
        system could not be used in rpc authentication calls to NT DCE
        2.2 and Unix DCE 3.0 servers.

          An account created from a V1.4  or  V1.5  OpenVMS  system  via
          rgy_edit  caused a principal unknown error to be returned from
          a NT 2.2 or UNIX 3.0 system when  the  principal  account  was
          used in an rpc_binding_set_auth_info() call.




          Since day one rgy_edit on VMS has sent garbage  in  the  flags
          fields   of   the  admin_part  (sec_rgy_admin_t)  argument  to
          sec_rgy_acct_add(); It appears the garbage has  been  ingnored
          until  recent  updates to the security server in the 1.2.2 OSF
          base to implement a new "user to user" authentication feature.

          Accounts created from VMS would work in some cases  and  would
          not  work in many cases.  Whether it worked or not depended on
          a bit being set in one of the garbage arguments.

     o  Restart of RPCD or PERF server  fails  with  "unable  to  bind
        socket".

     Attempting to restart a DCE server with a well known endpoint, such
     as  RPCD  (port 135) or PERF server (port 2001) failed with "unable
     to bind socket" error, when there is no  process  using  the  port.
     This problem is corrected.

          Attempting to restart a DCE server with a well known endpoint,
          such  as RPCD (port 135) or PERF server (port 2001) fails with
          an "unable to bind socket" error, when  there  is  no  process
          using  the  port.   Restart  of RPCD could fail with a message
          that  RPCD  was  already  running.   Client  incoming  packets
          referencing the well-known endpoint create Port Control Blocks
          for the endpoint.  A socket cannot be bound to a port with  an
          existing PCB unless the SO_REUSEADDRESS socket option is set.

         

PROBLEMS ADDRESSED IN VAXDCE02_014:

  o  When a file required for an IDL compile was not located in  the
     first location in a directory logical name search list, the IDL        
     compile fails with:                                                    
                                                                        
     %IDL-E-OPENREAD, Unable to open idl_sources:[guy]test1.idl for read access
     %IDL-E-SYSERRMSG, System error message: no such file or directory      
     %IDL-F-COMPABORT, Compilation aborted                                  
                                                                        
                                                                        
  o  User applications passing fixed  arrays  containing  structures        
     between  Alpha  VMSand  other platforms encounter corruption in        
     the array contents.                                                    

  o  DCE Servers die with the following error messages:

         + Listening...
         (socket) rpc__socket_disp_select *** FATAL ERROR at
                  SOCKDISPATCH.C;1\3668 **
           %CMA-F-EXCCOP, exception raised; VMS condition code follows
           -SYSTEM-F-OPCCUS, opcode reserved to customer fault at
           PC=FFFFFFFF80538638,PS=000001B %SYSTEM-F-ABORT, abort


  o  Configuring a OpenVMS DCE 1.4 client  into  a  Gradient  server
     running on NT4.0 results in the following error:

         Establishing security environment for principal "cell_admin" . . .

         ****************************    ERROR    ****************************
         ***  An error occurred while setting up the security environment
         ***  using principal name "cell_admin"
         Error: Cannot validate identity for principal "cell_admin"
         who are you failed (dce / rpc) 236094202
         %SYSTEM-F-ABORT, abort


PROBLEMS ADDRESSED IN VAXDCE01_014:

  o  When    the     security     server     is     not     running,
     sec_login_refresh_identity()  returns  an  undocumented  status
     code,   336760967.    The   documentation   states   that   the
     sec_rgy_server_unavailable  status  code  should  be  returned.
     Example programs from OSF and other vendors  show  the  refresh
     thread  testing  for  the  sec_rgy_server_unavailable status to
     determine if the refresh should be retried


  o  Executing any RPCLM command results in a  fault  invalid  bound
     message on Alpha systems.

     $RPCLM String Binding of Server:ncadg_ip_udp:16.32.80.42[2301]
     RPCLM> inq
          %CMA-F-EXCCOPLOS, exception raised; some information lost
          -DCERPC-E-FAULTINVALIDBOU, fault invalid bound (DCE / RPC)

  o  In the directory  DCE$SPECIFIC:[KRB5]  there  are  hundreds  of
     versions  of  KRB5KDC_RCACHE  created  in  it  by  the DCE$SECD
     process.   These  files  do  get  cleaned  up  during  a  CLEAN
     operation  but,  they  are  not  cleaned  up  during a start or
     restart of DCE.

  o  If  you  do  not   include      prior   to   including
       the header will not compile because it uses the
     datatype FILE*.

  o  Attempting a kinit on an OpenVMS system results  in  the  error
     below:

     $ kinit cell_admin
     $5$dkb0:[sys0.syscommon.][sysexe]dce$kinit.exe;4: Malformed
     representation of principal when parsing name T@

  o  When an 'Illegal state transition' occurs, the correct state is
     not  reported.   The  code clobbered the state before reporting
     it.  A state of 255 is reported and is meaningless  because  it
     is the code for No State.

  o  Print 4 digit years on output from DCE processes.   Allow  four
     digit  data inputs from DCE administration functions.  Fix leap
     year calculations for years after 2017.

  o  It has been discovered that OSF/DCE has a potential problem  in
     the  security  server  that could allow for a denial of service
     attack.

     If a principal, group, or organization  is  greater  than  1024
     characters  (including  the cell name, so the actual name limit
     is less than 1024) when passed to security  daemon  (secd),  it
     will  cause  secd  core  dump.   The  buffer is overrun causing
     memory corruption.  In certain cases, the  lookup  attempt  (or
     add or whatever) on the client will then rebind to another secd
     to make the request, eventually crashing all  security  daemons
     in the cell.

  o  The new Pathway  IP  version  can  cause  DCE  setup  to  abort
     abruptly with error messages.  Pathway changes the output of an
     image that returns the Pathway  version.   This  causes  output
     parsing routines to fail because they search for runtime on the
     line containing the version.


INSTALLATION NOTES:

     Install this kit with the VMSINSTAL utility  by  logging  into  the
     SYSTEM account, and typing the following at the DCL prompt:

         @SYS$UPDATE:VMSINSTAL VAXDCE03_014 [location of the saveset]

     The saveset location may be a tape drive, or a disk directory  that
     contains the kit saveset.

     No reboot is necessary after successful installation  of  the  kit.
     However,  DCE  must  be  re-started  after  the kit is installed to
     complete the installation of  the  new  DCE  images.   DCE  can  be
     restarted with the comand

          @SYS$MANAGER:DCE$SETUP START

Files on this server are as follows:
»vaxdce03_014.README
».CHKSUM
»vaxdce03_014.a-dcx_vaxexe
»vaxdce03_014.b-dcx_vaxexe
»vaxdce03_014.CVRLET_TXT
privacy statement using this site means you accept its terms