Content starts here
DCE-VMS DCEECO_015_2-V0100 DCE V1.5 for OpenVMS Alpha ECO Summary
TITLE: DCE-VMS DCEECO_015_2-V0100 DCE V1.5 for OpenVMS Alpha ECO Summary

New Kit Date:       07-DEC-2001
Modification Date:  11-DEC-2001
Modification Type:  FIXED THE TYPO IN TITLE

NOTE:  An OpenVMS saveset or PCSI installation file is stored
       on the Internet in a self-expanding compressed file.
 
       For OpenVMS savesets, the name of the compressed saveset
       file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or
       kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS
       saveset is copied to your system, expand the compressed
       saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe.
 
       For PCSI files, once the PCSI file is copied to your system,
       rename the PCSI file to kitname.pcsi-dcx_axpexe, then it can
       be expanded by typing RUN kitname.pcsi-dcx_axpexe.  The resultant
       file will be the PCSI installation file which can be used to install
       the ECO.
 

 
 
Copyright (c) Compaq Computer Corporation 2000, 2001.  All rights reserved.

PRODUCT:    DCE V1.5 for OpenVMS Alpha

OP/SYS:     OpenVMS Alpha

SOURCE:     Compaq Computer Corporation

ECO INFORMATION:

     ECO Kit Name:  DCEECO_015_2-V0100
                    DEC-AXPVMS-DCEECO_015_2-V0100--4.PCSI
     ECO Kits Superseded by This ECO Kit:  DCEECO_015_1-V0100
     ECO Kit Approximate Size:  31472 Blocks
     Kit Applies To:  OpenVMS Alpha 6.2, V7.1, V7.1-2, V7.2, 
                                    V7.2-1 and V7.2-1H1.
                      DCE V1.5 for OpenVMS Alpha
     System/Cluster Reboot Necessary:  No
     Rolling Re-boot Supported:  Not Applicable
     Installation Rating:  INSTALL_2
                           2 - To be installed on all systems running
                               the listed version(s) of OpenVMS and
                               using the following feature(s):

                                 Compaq DCE V1.5 for OpenVMS Alpha

                           INSTALL_3
                           3 - The kit should be installed on systems
                               using the following feature if the
                               problems fixed are occurring:

                                 Compaq COM for OpenVMS


     Kit Dependencies:

       The following remedial kit(s), or later, must be installed BEFORE
       installation of this kit:

         VMS62TO71_PCSI-V0200

       In order to receive all the corrections listed in this
       kit, the following remedial kits, or later should also be installed:

         None


ECO KIT SUMMARY:

An ECO kit exists for DCE V1.5 on OpenVMS Alpha V6.2 through V7.2-1H1.  
This kit addresses the following problems:

PROBLEMS ADDRESSED IN DCEECO_015_2 KIT:

  o  DCE server processes such as DCE$SECD and DCE$CDSD, as well as
     user  written  DCE  servers sporadically abort with SS$_ACCVIO
     when hit with a fast burst of client request activity.

          Images Affected:  [SYSLIB]DCE$LIB_SHR.EXE


  o  The DCE$RPCD daemon generated thousands of error messages  and
     logged them into the DCE$RPCD.OUT file as:
     (rpc) *** FATAL ERROR (receive_dispatch) Unexpected exception

        raised at CNRCVR.C;2\587 ***

        (rpc) *** FATAL ERROR (rpc__cn_network_receiver) Unexpected

        exception is raised at CNRCVR.C;2\398 ***

          Images Affected:  [SYSLIB]DCE$LIB_SHR.EXE


  o  A process using  DCE  RPC  services  aborts  with  a  bugcheck
     similar to the one below:

     DECthreads bugcheck (version V3.15-262), terminating execution.
     % Reason:  mutex 0x00000000005DD868 :0 ref. overflow on lock

          Images Affected:  [SYSLIB]DCE$LIB_SHR.EXE


  o  After the installation of DCE V1.5 the IDENT, IDL,  and  RPCLM
     commands are missing from the system command tables.

          Images Affected:  [syslib]DCLTABLES.EXE


  o  After the installation of DCE V1.5 ECO 1  on  systems  without
     the  DCE-SECURITY  license  loaded,  dce_setup  fails with the
     following error:
     ****************************    ERROR    ****************************
       ***  Images required for running the DCE V1.5 ECO 1 for OpenVMS Alpha
       ***  product were not found on this system.  These images should have
       ***  have been placed on the system during the installation of this
       ***  product.
       ***
       ***  Please install the DCE V1.5 ECO 1 for OpenVMS Alpha product
       ***  to ensure that the required images are properly
       ***  installed on the system.

  o  The DCE$DTSD process aborts with the error CMA-F-EXCOPLOS  and
     a message of thread has been canceled.

           Images Affected:  [SYSMGR]DCE$SETUP.COM

  o  A new logical has been defined to allow customers to have  the
     DCE  daemon  files  produce  process  dumps.  The logical name
     DCE$DUMP_DAEMONS can be defined prior to dce  startup  to  add
     the  /DUMP qualifier to the daemon process.  Process dumps can
     only be reliably produced and read on  Alpha  V7.2-1  systems.
     You  must  install  special debugger kit ADB073 on your V7.2-1
     for the DCE dumps to be usable.  Please  contact  your  Compaq
     support representative to a copy of the ADB073 kit.

          Images Affected:  [SYSMGR]DCE$RPC_STARTUP.COM
                            [SYSMGR]DCE$SETUP.COM

PROBLEMS ADDRESSED IN DCEECO_015_1 KIT: 

  o  RPC authentication calls from NT DCE 2.2 clients fail with
     Principal Unknown errors although the principal is listed in
     the registry.  The failures occur for principals and accounts
     created from OpenVMS DCE.

       Images Affected:  [SYSEXE]DCE$RGY_EDIT.EXE

  o  Upon reboot of the system, startup hangs when one of the DCE
     CDS daemon processes fails to start.  Examination of the .OUT
     file shows the start fails with a messages stating the daemon
     is already running.

       Images Affected:
         -  [SYSEXE]DCE$CDSADV.EXE
         -  [SYSEXE]DCE$CDSD.EXE
         -  [SYSEXE]DCE$GDAD.EXE

  o  Directory of sys$manager or sys$scratch lists many
     DCE_OUT*.tmp files.

       Images Affected:
         -  [SYSMGR]DCE$SETUP.COM
         -  [SYSMGR]DCE$RPC_STARTUP.COM

  o  When starting DCE on a system running Multinet, the following
     DCL message is displayed.

       %DCL-W-UNDFIL, file has not been opened by DCL - check logical name

       Images Affected:  [SYSMGR]DCE$SETUP.COM

  o  Eliminate zero block files left in the credentials cache directory.  
     When a dce_login is performed, six files are created in the 
     credentials cache directory, DCE$SPECIFIC:[VAR.SECURITY.CREDS]. An 
     example is the following files:

       16   029D9101.;2           1-OCT-1998 15:28:18.37
       17   029D9101.;1           1-OCT-1998 15:28:17.76
       18   029D9102.;1           1-OCT-1998 15:28:19.27
       19   029D9200.;1           1-OCT-1998 15:28:19.02
       20   029D9200.DATA;1       1-OCT-1998 15:28:19.38
       21   029D9200.NC;1         1-OCT-1998 15:28:19.18

     After a kdestroy, two files remain from the original login.
     In the login example above, the following files are left:

       16   029D9101.;1           1-OCT-1998 15:28:17.76
       17   029D9102.;1           1-OCT-1998 15:28:19.27

       Images Affected:  [SYSLIB]DCE$LIB_SHR.EXE

  o  DCE login fails when the input for the password is not obtained
     from a terminal.  The login fails with the following error:

       $ rgy_edit
       Current site is: registry server at /.../the_cell/subsys/dce/sec/master
       l princ_name
       -dce-
       login: Credentials cache I/O operation failed XXX Error in input 
              password. Login failed.

       exit
       bye

       Images Affected:  [SYSLIB]DCE$LIB_SHR.EXE

  o  Every one hour, the sec_clientd daemons delete stale credentials 
     files out of the DCE credentials cache directory.  If run in 
     debug mode, the daemon deletes the files every five minutes.  The 
     interval is not adjustable.  Changes were made to make the interval 
     adjustable between 5 minutes and one hour.  The interval cannot 
     be greater than 60 minutes or less than 5 minutes.

     To set the interval, define the logical FCC_CCACHE_CLEANUP_INTERVAL,  
     to the number of minutes between cache cleanups.  The logical may be 
     defined at the system level, or may be defined in the sec_clientd 
     startup command procedure.  If the interval is changed while the 
     security client daemon is running, the new interval will be effective
     after the next credentials cache cleanup.

       Images Affected:  [SYSEXE]DCE$SEC_CLIENTD.EXE

  o  After the installation of Multinet 4.1 B-X, DCE will not
     configure.

       Images Affected:  [SYSMGR]DCE$SETUP_MULTINET.COM

  o  When a DCE server system failed or was shutdown, the security
     client daemon on client systems would not fail over to replica
     server systems.  DCE applications running on the client
     systems would be unable to refresh security credentials or
     have tickets validated.

       Images Affected:  [SYSMGR]DCE$SETUP.COM

  o  When DEC C compiler version 6.2 is installed, compilation of
     the IDL-generated C code may result in the following error(s)
     being displayed.  Some DCE images were updated to  fix extern
     model mismatches detected by the new C compiler.

       ........................^
           %CC-W-DIFFEXMODEL, This redeclaration of "xxxxxxxxxxxxxxxx_ifdef"
           specifies

       Images Affected:
         -  [SYSEXE]DCE$IDL.EXE
         -  [SYSEXE]DCE$RPCD.EXE
         -  [SYSEXE]DCE$SECD.EXE
         -  [SYSEXE]DCE$SEC_CREATE_DB.EXE
         -  [SYSEXE]DCE$SX.EXE

  o  The HOPF time provider provides year data in a 2 digit format.
     DCE interface to the provider had to be updated to use a
     sliding window to calculate the correct year.

       Images Affected:
         -  [SYSHLP.EXAMPLES.DCE.DTSS]DCE$DTS_PROVIDER.C
         -  [SYSHLP.EXAMPLES.DCE.DTSS]DCE$DTS_PROVIDER_HOPF.EXE

  o  DECnet RPC routines did not correctly update RPC memory  ousage
     statistics used for troubleshooting.

       Images Affected:
         -  [SYSLIB]DCE$LIB_SHR.EXE
         -  [SYSLIB]DCE$SOCSHR_DNET_OSI.EXE

  o  After running for some time, the CDS clerk process terminates
     with the following error:

       %SYSTEM-F-ACCVIO, access violation, reason mask=00, virtual
       address=00000001005BA96A, PC=0000000000051A94, PS=0000001B

       Images Affected:  [SYSEXE]DCE$CDSCLERK.EXE


  o  DCE applications which use the rpc_inq_stats function
     encounter random Accvios.  There is no pattern apparent 
     to the ACCVIOs encountered.

       Images Affected:
         -  [SYSLIB]DCE$LIB_SHR.EXE
         -  [DCE$LIBRARY]RPCTYPES.H
         -  [DCE$LIBRARY]RPCTYPES.IDL

  o  The is_local call did not work on DECnet OSI interface.

       Images Affected:  [SYSLIB]DCE$SOCKSHR_DNET_OSI.EXE

  o  OpenVMS DCOM client to NT component fails with RPC "Unknown
     reject" error.

     Applicable to OpenVMS V7.2 and V7.2-1 systems.

       Images Affected:  [SYSLIB]DCE$LIB_SHR.EXE

  o  Attempting to start a DCE server with a well-known endpoint,
     such as RPCD (port 135) or PERF server (port 2001) fails with
     "unable to bind socket" error, when TCP shows there is no
     process using the port.

       Images Affected:  [SYSLIB]DCE$LIB_SHR.EXE [image affected]...

  o  Fix spurious ACCVIOs occuring when using NTLM authentication
     over TCP.  The following error will be observed by processes
     encountering this problem:

       1999-11-07-11:08:00.919+00:00I----- PID#1076 FATAL rpc recv 
                                           CNRCVR.C;1 563
       0x01b0fb80
       (rpc__cn_network_receiver) Unexpected exception was raised

     Applicable to OpenVMS V7.2 and V7.2-1.

       Images Affected:  [SYSLIB]DCE$LIB_SHR.EXE

  o  Virtual memory usage of DCE processes is higher after the
     install of V1.5.

     Applicable to OpenVMS V7.2 and V7.2-1.

       Images Affected:  [SYSLIB]DCE$LIB_SHR.EXE

  o  When many clients attempt to connect to one server, the server
     may not be able to accept the connections as fast as the
     clients are requesting.

       Images Affected:  [SYSLIB]DCE$LIB_SHR.EXE

  o  DCOM client apps receive "who are you" failures caused by rpc
     protocol errors over UDP.

     Applicable to OpenVMS V7.2 and V7.2-1.

       Images Affected:  [SYSLIB]DCE$LIB_SHR.EXE

  o  Only uppercase "I" is allowed for inaccuracy token input from
     DTSCP.  Only the lowercase string "inf" was valid for infinite
     inaccuracy.  These inputs should not be case sensitive.

       Images Affected:
         -  [SYSLIB]DTSS$SHR.EXE
         -  [SYSEXE]DTSD.EXE

KNOWN PROBLEMS IN ALL PATCH LEVELS OF DCE V1.5:

  o  Configuring a server from the DCE setup and configuration menu
     on systems where DECNET OSI is a supported protocol fails with
     the error below when attempting to modify  an  acl  on  a  cds
     namespace entry:
     ****************************    ERROR    ****************************
     ***  Could not configure ACL info.  Failed command:
     ***  $ Dce$Acl_Edit -e /.:/
     ***  %CMA-F-NOMSG, Message number 10408014
          %CMA-F-EXCCOP, exception raised; VMS condition code follows
          -SYSTEM-F-ACCVIO, access violation, reason mask=00,
          virtual address=00000000004E6000, PC=FFFFFFFF8089EEFC, PS=0000001B

INSTALLATION NOTES:

Install this kit with the POLYCENTER Software installation  utility
by  logging  into  the  SYSTEM account.  After the installation you
must stop and restart DCE.  On OpenVMS V7.2 systems, you must  stop
and       restart       the       DCE$RPCD       process      using
SYS$MANAGER:DCE$RPC_SHTUDOWN.COM                                and
SYS$MANAGER:DCE$RPC_STARTUP.COM.

You may ignore any/all  of  the  following  messages  if  they  are
displayed during the installation process:

%PCSI-I-OBJSKP, file [DCE$LIBRARY]RPCTYPES.H pertains to an option that ...
%PCSI-I-OBJSKP, file [DCE$LIBRARY]RPCTYPES.IDL pertains to an option ...
%PCSI-I-OBJSKP, file [SYSHLP.EXAMPLES.DCE.DTSS]DCE$DTS_PROVIDER.C ...
%PCSI-I-OBJSKP, file [SYSHLP.EXAMPLES.DCE.SX]DCESX.C pertains to an ...
%PCSI-I-RETAIN, file [SYSLIB]DTSS$SHR.EXE was not replaced because file ...

No reboot is necessary after successful installation of the kit.
                  ...

All trademarks are the property of their respective owners.