Jump to page titleUNITED STATES
hp.com home products and services support and drivers solutions how to buy
» contact hp


more options
 
hp.com home
End of Jump to page title
HP Services Software Patches
Jump to content


» software & drivers
» ask Compaq
» reference library
» forums & communities
» support tools
» warranty information
» contact support
» parts
» give us feedback

patches by topic
» DOS
» OpenVMS
» Security
» Tru64 Unix
» Ultrix 32
» Windows
» Windows NT

associated links
» what's new
» contract access
» browse patch tree
» search patch tree
» join mailing list

connection tools
» nameserver lookup
» traceroute
» ping


Find Support Information and Customer Communities for Presario.
Content starts here
HP Services Software Patches - a1fcs_eco01031
 
NOTE:  An OpenVMS saveset or PCSI installation file is stored
       on the Internet in a self-expanding compressed file.
       The name of the compressed file will be kit_name-dcx_vaxexe
       for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
 
       Once the file is copied to your system, it can be expanded
       by typing RUN compressed_file.  The resultant file will
       be the OpenVMS saveset or PCSI installation file which
       can be used to install the ECO.
 
Copyright (c) Digital Equipment Corporation 1996.  All rights reserved.

PRODUCT:    ALL-IN-1 Office Server Options for OpenVMS AXP and 
            OpenVMS VAX, V3.1

COMPONENT:  File Cabinet Server

OP/SYS:     OpenVMS Alpha V6.1 or later
	    OpenVMS VAX V5.5-2 or later

SOURCE:     Digital Equipment Corporation

ECO INFORMATION:

     ECO Kit Name:  A1FCS_ECO01031
     ECO Kits Superseded by This ECO Kit:  None

     NOTE:  This ECO kit obsoletes the patch kits A1_FIX018031.BCK, 
            A1_FIX022031.BCK, A1_FIX025031.BCK, A1_FIX032031.A, 
            and A1_FIX035031.A.

     ECO Kit Approximate Size:  A1FCS_ECO01031.A - 10,800 Blocks
     System Reboot Necessary:  No


ECO KIT SUMMARY:

An ECO kit exists for ALL-IN-1 Office Server Options (File Server
Component) for OpenVMS AXP and OpenVMS VAX Version 3.1 on OpenVMS Alpha
V6.1 or later and OpenVMS VAX V5.5-2 or later. 

The A1FCS_ECO01031 Release Notes contain a complete explanation of this
release.  Below is a brief description: 

  o  Improved FCS Error Trapping

     The FCS error trapping mechanisms have been improved, particularly
     around selected system service calls, which under certain conditions
     caused the FCS process to stop processing client requests.

  o  Accessing the Distributed Sharing Option

     When the DSO license is not installed on a system, any remote request
     to that server fails (intentionally) with an information message in
     the log file.  Extra information is now added to such messages with
     details of the user and originating node of the remote request.

  o  FCS Error diagnostics

     Error and information messages inserted into FCS logfiles were
     insufficiently descriptive.  These have now been improved to
     facilitate diagnostics.

  o  FCS shutdown leaves documents locked

     Some exception conditions (alerts) cause documents to remain locked
     after the FCS has finished handling them.  Such documents could not
     then be accessed until the FCS was restarted.

  o  MSG directory creation

     When creating drawers from Teamlinks the File Cabinet Server doesn't
     create a [.MSG] directory if the drawer isn't a Mail drawer.
     Documents were filed in the top level directory and were unreadable
     thereafter.

  o  FCS CPU loop

     The File Cabinet Server sometimes enters a tight CPU loop when
     accessing its internal cache of Drawer information.  The FCS 
     stops services TeamLinks and IOS requests at this point.

  o  File Cabinet Server Connection hangs

     To access an object in a remote file cabinet, the local File Cabinet
     Server must connect to the remote FCS.  While the local FCS is
     establishing this connection, the requesting client cannot continue
     with any work. 

     To avoid an indefinite period of inactivity resulting from a failure
     to connect, a limit has been set to the time that a local File
     Cabinet Server can take to establish a connection to a remote server.
     If a connection cannot be established within this time, the attempt
     is abandoned, and the client can continue with other work.

  o  Brokering between remote FCS processes

     The FCS sometimes enters a CPU loop when performing a remote
     operation if the remote FCS process encounters an unexpected failure
     (eg internal access violation). The FCS stops services TeamLinks and
     IOS requests at this point.

  o  Refiling documents with Attachments across Drawers

     Occasionally when refiling documents with attachments across drawers,
     the FCS 'thread' performing the refile operation on behalf of the
     user will experience an Access Violation due to internal data
     corruption.

  o  Creating RESERVATIONS.DAT and FILECAB.DAT under VMS V7.0 

     When running on OpenVMS V7.0 the server fails when creating
     RESERVATIONS.DAT or FILECAB.DAT due to the call to lock the mutex
     passing a parameter incorrectly.

  o  Reverse logic of OAFC$EXCLUSIVE_LOCK_OFF logical.

     TLC V2.5 introduced the OAFC$EXCLUSIVE_LOCK_OFF logical to allow
     exclusive locking to be turned off.  This behaviour is now default.
     In the unlikely event of requiring the original behaviour to be 
     restored to use exclusive locking, define the logical 
     OAFC$EXCLUSIVE_LOCK_OFF as follows:

        $ DEFINE/SYSTEM OAFC$EXCLUSIVE_LOCK_OFF "N"

     You will need to restart the File Cabinet Server for this change to 
     become effective.

  o  Connect/Disconnect timing problems. 

     The server will sometimes terminate or report fatal problems when the
     server attempts to disconnect sessions that no longer exist.  

  o  Document remains locked after attaching it to a message.

     When sending a mail with an attachment from a shared drawer using
     TeamLinks, the File Cabinet Server locks the DAF.DAT of the
     attachment and fails to release it after the operation is complete.
     This causes document locking problems.

  o  Server problems due to low resources.
     
     This patch introduces a resource monitor to watch resource utilization
     levels, and issue warnings to the log file when they reach set 
     boundaries.

  o  Distribution Lists created from TeamLinks cannot be used from VT
     
     When a distribution list is created from TeamLinks you cannot use
     this distribution list from ALL-IN-1.  This has only been reported
     against Brazilian version of ALL-IN-1 V3.0A, but will also occur with
     other languages added for V3.0A. e.g.  Hungarian, Polish, Russian,
     Slovensky and Turkish for V3.0A and V3.1.

  o  Problems due to Server-Client Disconnects

     When a client session connection is broken unintentionally (e.g. by
     CTRL-Y, switching off a PC, or network breaks) during critical
     processing the server may report an Access Violation and stop or
     hang.         


INSTALLATION NOTES:

Before you install patch A1FCS_ECO01031, you must shut down ALL-IN-1.

Use the Shutdown ALL-IN-1 (SDA) option on the ALL-IN-1 Administration
menu (ADM) of the Management subsystem.  This will automatically shut
down your sender and fetcher processes and all servers.

See the ALL-IN-1 Management Guide for more details. TeamLinks users
will be temporarily unable to access the ALL-IN-1 file cabinet.

There are several stages to installing an ALL-IN-1 IOS V3.1 patch
kit, which vary according to the configuration of the target system
and the contents of each patch kit.

There will always be a primary installation - typically supplying
revised object modules (.OBJs), revised script files (.SCPs) or
revised named data for ALL-IN-1 forms (.FRMs).

This patch kit supplies revised image files and therefore you will 
need to perform a primary installation AND a second architecture
installation (if you have a mixed architecture VMScluster).

The installation procedure will automatically relink the required
OA$FC$SERVER.EXE image and move this to its target directory.

To install this patch, log into the SYSTEM account and use the
command procedure SYS$UPDATE:VMSINSTAL.COM as follows:

   $ SET DEFAULT SYS$UPDATE
   $ @VMSINSTAL A1FCS_ECO01031 'device'

where 'device' is the name of the device on which the distribution
medium will be mounted or the device:directory where you have already
copied the kit to.

When the installation has completed successfully repeat the above
procedure on your second architecture system (if you run ALL-IN-1 on
a mixed architecture VMScluster).

Once you have installed A1FCS_ECO01031, do the following:

   o  Restart ALL-IN-1 by executing the following command

         $ @SYS$STARTUP:A1V31START

      If you run ALL-IN-1 on an Open VMScluster system, execute the
      startup command procedure on every node of your VMScluster 
      where ALL-IN-1 is used.

   o  Reapply customizations if required.