Requirements:
1) Hardware must be year 2000 ready (check with your hardware vendor).
2) Install the CLIB updates.
3) All the latest patches/fixes must already installed on the server.
4) Make a back-up copy or rename the original files before replacing them.
To install patch:
1) Verify that the server is running the current OS patches from in 312PTD.EXE or later.
2) Down the server and copy TTSY2KFX.NLM to the patch director as installed by the OS patch kit, in ths case the PMLOAD command will load TTSY2KFX.NLM in addition to the released patches. Or copy the patch to a different directory on the boot drive and add a seprate line to the startup.ncf to load TTSY2KFX.NLM after the load pm312 and pmload statements.
For example:
LOAD C:\NWSERVER\PATCHES\4START\PM312
PMLOAD C:\NWSERVER\PATCHES\START
LOAD C:\NWSERVER\TESTPAT\TTSY2KFX
3) Restart the server and then verify that the patch has been loaded by using the "modules" command.
|