Technical Information Document
FILER.EXE 3.76 Corrects Volume Information - TID13722 (last modified 12NOV1997)
13722 13722
associated file

Click filename to download:
fil376.exe; 158446 bytes; Date/Time: 11-10-1993/06:15PM

abstract

This version of Filer corrects inaccurate numbers being reported by Volume Information with volumes over 2 GB. The Filer included is the same as the file included with NetWare 3.12.

installation

1. Use the same support files for this new Filer as for the version used in NetWare 3.11.

2. Flag FILER.EXE SRW, and rename the file.

3. Copy this new Filer program, and flag it SRO (syntax FLAG FILER.EXE SRO).

symptoms

When reviewing Volume Information in Filer, numbers shown are negative, or otherwise inaccurate.

troubleshooting

This problem only occurs on volumes over 2 GB.

cause

The use of a signed long integer to hold volume information as oppose to a unsigned long integer.

solutions

Use Filer 3.76 to solve this problem.

contents

Self-Extracting File Name:  fil376.exe

Files Included       Size   Date         Time    Version   Checksum

\
    FIL376.TXT       1963   11-10-1993   05:13PM
     FILER.EXE     305986   08-11-1993   04:05PM
Document Title: FILER.EXE 3.76 Corrects Volume Information
Document ID: 13722
Creation Date: 10NOV1993
Modified Date: 12NOV1997
Document Revision: 2
Novell Product Class: NetWare
Novell Product and Version: NetWare 3.11

Disclaimer

The Origin of this information may be internal or external to Novell. Novell makes all reasonable efforts to verify this information. However, the information provided in this document is for your information only. Novell makes no explicit or implied claims to the validity of this information.

Any trademarks referenced in this document are the property of their respective owners. Consult your product manuals for complete trademark information.