FILER.EXE 3.76 Corrects Volume Information - TID13722 (last modified 12NOV1997)
13722
13722
associated file
Click filename to download:
fil376.exe; 158446 bytes; Date/Time: 11-10-1993/06:15PM
abstract
This version of Filer corrects inaccurate numbers being reported by Volume Information with volumes over 2 GB. The Filer included is the same as the file included with NetWare 3.12.
installation
1. Use the same support files for this new Filer as for the version used in NetWare 3.11.
2. Flag FILER.EXE SRW, and rename the file.
3. Copy this new Filer program, and flag it SRO (syntax FLAG FILER.EXE SRO).
symptoms
When reviewing Volume Information in Filer, numbers shown are negative, or otherwise inaccurate.
troubleshooting
This problem only occurs on volumes over 2 GB.
cause
The use of a signed long integer to hold volume information as oppose to a unsigned long integer.
solutions
Use Filer 3.76 to solve this problem.
contents
Self-Extracting File Name: fil376.exe
Files Included Size Date Time Version Checksum
\
FIL376.TXT 1963 11-10-1993 05:13PM
FILER.EXE 305986 08-11-1993 04:05PM
Document Title:
FILER.EXE 3.76 Corrects Volume Information
Document ID:
13722
Creation Date:
10NOV1993
Modified Date:
12NOV1997
Document Revision:
2
Novell Product Class:
NetWare
Novell Product and Version:
NetWare 3.11
Disclaimer
The Origin of this information may be internal or external to Novell. Novell makes all reasonable efforts to verify this information. However, the information provided in this document is for your information only. Novell makes no explicit or implied claims to the validity of this information.
Any trademarks referenced in this document are the property of their respective owners. Consult your product manuals for complete trademark information.