Windows May Not Load on AEG Olympia LT 386sx Laptop (79091)
The information in this article applies to:
This article was previously published under Q79091 SUMMARY
Microsoft Windows version 3.0 may not run on an AEG Olympia LT 386sx
Laptop computer if the screen saver and low-battery alert options are
enabled in the CMOS setup of the system.
MORE INFORMATION
AEG Olympia has confirmed that Windows may not run in any mode on the
Olympia LT 386sx laptop computer when the Power Saving Time-Out options
are not set to Default.
The Power Saving Time-Out option consists of a low-battery alert and a
built-in screen saver feature. When this option is set to Default, both
of these features are disabled and Windows should load successfully.
Information on how to set these options can be found on page 6-5 of "The
Laptop User's Guide" for the AEG Olympia LT 386sx.
Attempting to run Windows with either of these option enabled causes the
system to display a blank screen and stop responding (hang). The only
solution to this problem is to disable both of these options in the system
CMOS setup.
Modification Type: | Minor | Last Reviewed: | 7/19/2005 |
---|
Keywords: | KB79091 |
---|
|