How to troubleshoot error 1928 "Error registering COM+ application" (308940)
The information in this article applies to:
- Microsoft COM+ 1.0
- Microsoft COM+ 1.5
- Microsoft Visual Studio Installer 1.0
- Microsoft Visual Studio Installer 1.1
This article was previously published under Q308940 SUMMARY This article describes how to troubleshoot error 1928
"Error registering COM+ application." You may receive this error message when
you run an .msi file (which is created when you export a COM+ application) on a
client computer or another server computer. MORE INFORMATION The cause of this error message is usually divided into two
distinct areas:
- Dependency issues
- Permissions issues
Dependency issues The steps to troubleshoot dependency problems differ depending on
how you exported the application. You can export a COM+ application in two
different ways:
- Application proxy
- Server application
Exporting as an application proxy If you exported the COM+ application as an application proxy,
follow these steps to troubleshoot error 1928. Note To create an application proxy
in Microsoft Windows Server 2003 or in Microsoft Windows XP that will install on a Microsoft Windows 2000-based computer, you
must click to select the Save application in COM+ 1.0 format check box. - To rule out a dependency issue, simply export the type
library (.tlb or typelib) files instead of the dynamic-link libraries (DLLs).
- If your components are built with Microsoft Visual
Basic, a separate typelib is not automatically created for you.
For more information about how to create a
separate typelib for your DLL, click the following article number to view the article in the Microsoft Knowledge Base:
153569
How to get a Typelib (.tlb) file for a Visual Basic OLE server
- If all of your client computers are running Microsoft
Windows 2000, verify that you have at least Windows 2000 Service Pack 2 (SP2)
installed on the COM+ server.
- If some of your client computers are running Microsoft
Windows NT 4.0, Microsoft Windows 98, or Microsoft Windows 95, verify that you
also have at least Windows 2000 Post-Service Pack 2 COM+ Hotfix Rollup 9
installed on the COM+ server.
Note To check which hotfixes are installed on the server, view the
subkeys under the following key in your registry:HKEY_LOCAL_MACHINE\Software\Microsoft\Windows NT\CurrentVersion\HotFix When you export the typelibs for your COM+ application, you
not only eliminate potential dependency problems, you also minimize the number
of files that are installed on the client computer. Because the object is
created on the server, the client computer only needs the interface definitions
(which is all that a typelib is) and not the full implementation of the
DLL.
To install a typelib into a COM+ application, follow these
steps:
- On the Start menu, point to Programs, point to Administrative Tools, and then click Component Services to open the Component Services Microsoft Management Console (MMC)
and create your new COM+ application.
- In Component Services, click to expand the Component Services, Computers, My Computer, and COM+ Applications nodes.
- Click to expand your new COM+ application.
- Right-click the Components folder, point to New, and then click Component.
- In the COM Component Install Wizard, click Next.
- On the second page of the wizard, click Install
new component(s).
- When the wizard prompts you to select your component,
select both the .dll file and the .tlb file. Notice that you cannot see the .tlb file in the
Component Services MMC; you can only see the DLL.
- After you install your component, export your COM+
application as an application proxy.
- When you export the typelibs for your COM+ application,
you not only eliminate potential dependency problems, you also minimize the
number of files that are installed on the client computer. Because the object
is created on the server, the client computer only needs the interface
definitions (which is all that a typelib is) and not the full implementation of
the DLL.Run the .msi file on your client computer. If error 1928 occurred
because of a dependency issue, the .msi file should run smoothly on the client
computer. Search the file system of the client computer, and notice that only
the .tlb file for your component has been installed.
- If you still receive error 1928 when you run the .msi file
on the client computer, you most likely have a permissions issue on the client
computer.
Exporting as a server applicationNote To create an application proxy
in Microsoft Windows Server 2003 or in Microsoft Windows XP that will install on a Microsoft Windows 2000-based computer, you
must click to select the Save application in COM+ 1.0 format check box. When you export your COM+
application as a server application, you cannot export only the typelib because
the server requires the full implementation of the DLL. If DLLs in
your COM+ application contain dependencies that are not present on the new
target Microsoft Windows XP Server or Microsoft Windows 2000 Server, you must
ensure that these DLLs are registered properly on the target server before you
run the .msi file on the target server.
If the dependencies are not Component Object Model (COM)
DLLs, ensure that they are installed in the
windir\WINNT\System32 folder of the target server
before you run the .msi file. If you continue to receive error 1928
after you try these troubleshooting methods, follow these steps on the target
computer (the computer from which you run the .msi file) to obtain more useful
error information:
- Open the Component Services MMC.
- Click to expand the Component Services, Computers, and My Computer nodes.
- Click and then right-click COM+ Applications, point to New, and then click Application.
- In the COM Application Install Wizard, click Next.
- On the second page of the wizard, click Install
pre-built application(s).
- When the wizard prompts you to choose either a default
directory or a specific directory, choose Default directory, and then complete the steps in the wizard.
- The wizard generates two error message dialog boxes. In the
second error message dialog box, click Details to obtain more detailed error information. This error information
may provide better insight about the cause of the problem.
Permissions issues The steps to troubleshoot a permissions issue do not necessarily
depend on how you exported the COM+ application. When you troubleshoot a
permissions issue, the primary goal is to make sure that the user who is
currently logged on to the client computer has the necessary permissions to run
the .msi file. For example, the user must have read/write permissions
to the HKEY_CLASSES_ROOT registry subtree. The Regmon and Filemon utilities (which are
available from SysInternals) may provide
assistance. Note Installing Crystal Reports 8.0 is known to alter the permissions
on certain registry keys.
For more information, click the following article number to view the article in the Microsoft Knowledge Base:
266621
Error "Library not registered" with Crystal Reports 8.0
Modification Type: | Major | Last Reviewed: | 11/8/2005 |
---|
Keywords: | kbhowto KB308940 kbAudDeveloper |
---|
|