FIX: New STA Object Cannot Join Caller's STA If the Caller Is Not Configured (298127)
The information in this article applies to:
- Microsoft COM+ 1.0, when used with:
- the operating system: Microsoft Windows 2000 SP2
This article was previously published under Q298127 SYMPTOMS
If a COM+ component (Component1) is marked as single-threaded apartment (STA), when Component1 is instantiated by an STA thread that is not from the COM+ STA thread pool, Component1 is not created in the caller's thread. In other words, Component1 is bound with one of the threads from the COM+ STA thread pool.
CAUSE
When the object from Component1 is instantiated from an STA, the apartment of the caller's thread is only checked if it is in the COM+ STA thread pool. If possible, create all COM+ objects that live on STA threads in the caller's thread. This bug violates this COM+ rule.
RESOLUTIONTo resolve this problem, obtain the latest service pack for Windows 2000. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
260910 How to Obtain the Latest Windows 2000 Service Pack
This fix is included with the fixes that are described in the following Microsoft Knowledge Base article:
299407 INFO: Post Windows 2000 Service Pack 2 COM+ Rollup Hotfix 13 Is Available
STATUSMicrosoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article. This problem was first corrected in Windows 2000 Service Pack 3.
Modification Type: | Major | Last Reviewed: | 5/28/2003 |
---|
Keywords: | kbbug kbfix kbWin2000PreSP3Fix kbWin2000sp3fix KB298127 |
---|
|