TN3270 Print Session Connection Fails on Non-default Port (280139)
The information in this article applies to:
- Microsoft Host Integration Server 2004
- Microsoft Host Integration Server 2000
- Microsoft SNA Server 3.0 SP1
- Microsoft SNA Server 3.0 SP2
- Microsoft SNA Server 3.0 SP3
- Microsoft SNA Server 3.0 SP4
- Microsoft SNA Server 4.0
- Microsoft SNA Server 4.0 SP1
- Microsoft SNA Server 4.0 SP2
- Microsoft SNA Server 4.0 SP3
This article was previously published under Q280139 SUMMARY
The session properties page for a TN3270 Logical Unit (LU) allows the LU to be configured for a port other than the default of 23. If the session is configured for a type of "Display," the connection works as expected. If the session is configured for a type of "Printer," the session connects only if it is set to use the default port. If the TN3270 server is set for another port, a printer session will connect on that, and only that, configured port.
MORE INFORMATION
This is by design.
In Microsoft Host Integration Server, which is the successor to Microsoft SNA Server, the option to choose another port is unavailable (gray) if a type of Printer is selected.
Modification Type: | Major | Last Reviewed: | 3/21/2005 |
---|
Keywords: | KB280139 |
---|
|