Front Page Hit Counter Resets to Zero After Content Deployment Project Completes (250438)



The information in this article applies to:

  • Microsoft Site Server 3.0
  • Microsoft Site Server 3.0 Commerce Edition
  • Microsoft FrontPage 98 for Windows

This article was previously published under Q250438

SYMPTOMS

When using the Microsoft Site Server 3.0 Content Deployment service to replicate Front Page Webs, the Front Page Hit Counter on the destination server resets to zero.

CAUSE

The counter is reset to zero due to the hit counter files in the _private directory being updated.

RESOLUTION

To prevent the hit counter files from being over written you will need to add an exclude filter for the _private directory in the Front Page Web to the Content Deployment project. Use the following steps to add an exclude filter.
  1. Open properties for the Content Deployment project.
  2. Select the FILTERS tab.
  3. Click ADD to add a new filter.
  4. Select EXCLUDE as the first option and DIRECTORY as the second option.
  5. Specify the physical path to the _private directory.
  6. Click OK.

Modification Type:MinorLast Reviewed:7/15/2004
Keywords:kbprb KB250438