Usage Analysis Import History Manager Produces a "Run-time error. '6': Overflow" Warning (241014)



The information in this article applies to:

  • Microsoft Site Server 3.0
  • Microsoft Site Server 3.0 Commerce Edition

This article was previously published under Q241014

SYMPTOMS

When attempting to use Site Server 3.0 Usage Analysis Import History Manager in the Usage Import module, the following warning dialog box appears:
Microsoft Site Server Analysis
Run-time error. '6':
Overflow
OK
When you click OK, the program exits.

CAUSE

More than 2519 logs have been imported into Usage Import. Internally, Import History Manager is multiplying the number of logs imported by two other large numbers. The product exceeds the maximum value for an integer.

RESOLUTION

To resolve this problem, obtain the latest service pack for Site Server 3.0. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:

219292 How to Obtain the Latest Site Server 3.0 Service Pack

STATUS

This problem was first corrected in Site Server 3.0 Service Pack 3.

MORE INFORMATION


Modification Type:MajorLast Reviewed:6/29/2004
Keywords:kbbug kbfix kbQFE KB241014