SMS: Failed Connection To Software Metering Server Does Not Differentiate Between Online and Offline Clients (235786)



The information in this article applies to:

  • Microsoft Systems Management Server 2.0

This article was previously published under Q235786

SYMPTOMS

Software Metering clients, both in offline and online mode, connect to the Software Metering server on a regular basis to transfer data. If the primary Software Metering server is unavailable, the client might continually try to connect to it rather than try the next available server.

This behavior is the same for both offline and online Software Metering clients.

However, there is no need for offline clients to continually try to connect to their Software Metering server when there are others available to connect to. Offline clients only have to upload saved Software Metering data that can be sent to any available Software Metering server, they do not have to wait for the primary server to become available.

CAUSE

Because licenses are allocated to Software Metering servers based on demand, online Software Metering clients should stay with a Software Metering server once assigned. This logic also applies to offline Software Metering clients.

RESOLUTION

To resolve this problem, obtain the latest service pack for Systems Management Server 2.0. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:

236325 SMS: How to Obtain the Latest Systems Management Server 2.0 Service Pack


The English version of this fix should have the following file attributes or later:

DateTimeVersionSizeFile namePlatform
6/21/9912:02pm67compver.iniIntel
6/17/991:10am2.00.1239.004888,416liccli95.exeIntel
6/17/991:10am2.00.1239.004889,440licclint.exeIntel
6/21/9912:02pm67 compver.iniAlpha
6/17/991:10am2.00.1239.0048126,224licclint.exeAlpha

STATUS

Microsoft has confirmed that this is a problem in Systems Management Server 2.0. This problem was first corrected in Systems Management Server 2.0 Service Pack Service Pack 1.

MORE INFORMATION

To install the hotfix, do the following at the SMS Site Server:
  1. Stop the SMS_EXECUTIVE and the SMS_Site_Component_Manager services.
  2. Replace the licclint.exe in the sms_root_directory\inboxes\clicomp.src\licmtr\platform\ directory with the version obtained from the hotfix.
  3. Replace the liccli95.exe in the sms_root_directory\inboxes\clicomp.src\licmtr\i386\ directory with the version obtained from the hotfix.
  4. Replace the compver.ini in the sms_root_directory\inboxes\clicomp.src\licmtr\ directory with the version obtained from the hotfix.
  5. Restart the SMS_EXECUTIVE and the SMS_Site_Component_Manager services. The files are replicated to the client access points (CAPs) and the logon points. Once this occurs, the clients will be updated at their next polling cycle.
NOTE: The default Client Configuration Installation Manager (CCIM) polling interval is 23 hours. Therefore, it may take up to 23 hours for the files that are in this hotfix to be propagated to the clients. To speed up this process, you can stop and then restart the SMS Client Service on each client. You can also create a software distribution by using the Setevnt.exe or the Cliutils.exe Resource Kit tools. You must include the appropriate parameters to start a CCIM work cycle. For information about the proper syntax for these tools, see the Resource Kit documentation.

Modification Type:MajorLast Reviewed:4/7/2006
Keywords:kbQFE KBHotfixServer kbBug kbfix KB235786