SYMPTOMS
Running an application that employs repeated calls to the CHRTRAN() function can result in the following error in Visual FoxPro 6.0:
Fatal error: Exception code=C0000005
Called from - <procedure name and line number> {<path and filename>}
The procedure name and line number will contain the method or procedure containing the CHRTRAN() function and its line number. Note that the line number will be 0 if the executable was built with the Debug Info checkbox in the Project Information dialog unchecked. The path and filename will contain the path and filename of the file containing the method or procedure.
Under the same circumstances, Visual FoxPro 5.0 may produce an error similar to the following under Windows NT:
An application error has occurred and an application error log is being generated.
vfp.exe
Exception: access violation (0xc0000005),Address 0xnnnnnnnn
Under Windows 9x, Visual FoxPro 5.0 may produce an error similar to the following:
VFP caused an invalid page fault in module <module name>