PRB: Type Mismatch Error in Client After Modifying Server DLL (190460)
The information in this article applies to:
- Microsoft Visual Basic Learning Edition for Windows 6.0
- Microsoft Visual Basic Professional Edition for Windows 6.0
- Microsoft Visual Basic Enterprise Edition for Windows 6.0
This article was previously published under Q190460 SYMPTOMS
If an ActiveX DLL server has two classes and one class implements the
other, running a compiled client project referencing the server will
generate the following error after modifying and recompiling the server
with binary compatibility:
Run-time error 13: Type mismatch
RESOLUTION
Reopen the client project and compile it again.
STATUS
This behavior is by design.
Modification Type: | Minor | Last Reviewed: | 3/3/2005 |
---|
Keywords: | kbCompiler kbprb KB190460 |
---|
|