Dynamic Definition of Dependent APPC LUs Doesn't Work Properly (182577)



The information in this article applies to:

  • Microsoft SNA Server 3.0
  • Microsoft SNA Server 3.0 SP1
  • Microsoft SNA Server 3.0 SP2
  • Microsoft SNA Server 3.0 SP3
  • Microsoft SNA Server 4.0

This article was previously published under Q182577

SYMPTOMS

If a dependent Local APPC LU is defined on two different connections (where each connection is configured to support Dynamic Definition of Remote APPC LUs), and the APPC application attempts to allocate a conversation over each Local LU to the same Remote APPC LU, the SNA INITSELF command for both dependent sessions flows over the first connection only.

CAUSE

Dynamic definition of dependent APPC LUs is not working correctly. If two remote APPC LUs are given the same name but defined to use different connections, the allocate to the second APPC LU causes the initself command to be sent across the wrong connection.

STATUS

Microsoft has confirmed that this is a problem in SNA Server 3.0, 3.0 SP1, 3.0 SP2, 3.0 SP3 and4.0. This problem was corrected in the latest SNA Server version 4.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K


Modification Type:MinorLast Reviewed:6/5/2006
Keywords:kbHotfixServer kbQFE kbbug kbfix KB182577