SYMPTOMS

The following problem occurs when you use the SNA Server 4.0 snap-in administrative interface to the Microsoft Management Console (MMC). If the start button in SNA Server version 4.0 is used to start a service, the start button will remain disabled after the service has been started. If you use the mouse to click on another location and then back, the button will reflect the correct status.

Starting an already started service leaves it pending indefinitely. The same situation applies when stopping a service and when using the Save Config button. This problem does not occur when you use the SNA Server 4.0 Manager interface.

STATUS

Microsoft has confirmed this to be a problem in SNA Server version 4.0. This problem was corrected in the latest SNA Server version 4.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K


Modification Type:MinorLast Reviewed:9/22/2005
Keywords:kbHotfixServer kbQFE kbbug kbfix KB180692