LU Assigned to a Workstation Disappears After Restart (172478)
The information in this article applies to:
- Microsoft SNA Server 3.0
- Microsoft SNA Server 3.0 SP1
This article was previously published under Q172478 SYMPTOMS
If the name of a Logical Unit (LU) is the same as the name of the
workstation this particular LU is assigned to, it will disappear from
within SNA Manager after SNA Manager has been restarted.
CAUSE
SNA Manager uses the same function when checking both for duplicate
workstation entries and for duplicate workstation LU configuration records.
SNA Manager does not distinguish between the two. So, when a workstation is
found with the same name as the workstation LU record being added, it will
fail because it is assumed to be a duplicate Workstation name.
STATUS
Microsoft has confirmed this to be a problem in SNA Server versions 3.0 and
3.0 Service Pack 1 (SP1). This problem was corrected in the latest SNA
Server version 3.0 U.S. Service Pack. For information on obtaining this
Service Pack, query on the following word in the Microsoft Knowledge Base
(without the spaces):
Modification Type: | Major | Last Reviewed: | 6/28/2004 |
---|
Keywords: | kbbug kbfix kbnetwork KB172478 |
---|
|