STOP 0x0000001E with DPT PM2124 SCSI Adapter and Volume Set (163726)
The information in this article applies to:
- Microsoft Windows NT Server 3.51
- Microsoft Windows NT Workstation 3.51
This article was previously published under Q163726 SYMPTOMS
After you create a volume set, the following error message is displayed on
the subsequent restart of the computer:
STOP 0x0000001E (0xC0000005, 0x80115B60, 0x0000001, 0x0000004)
KMODE_EXCEPTION_NOT_HANDLED *** address 80115B60 has base at 80100000 -
NTOSKRNL.EXE
CAUSE
If a volume set spanning 2 or more volumes is created when a DPT PM2124 no
cache PCI SCSI controller, this error may occur.
WORKAROUND
Obtain the latest Windows NT 3.51 driver for this card from DPT. At the
time of this article, the file NTMGR1J.ZIP can be obtained at DPT's Web
site:
The driver in this file, DPT_SCSI.SYS is version 1.Ka dated 7-20-96.
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 3.51. We
are researching this problem and will post new information here in the
Microsoft Knowledge Base as it becomes available.
MORE INFORMATION
The products mentioned here are manufactured by a vendor independent
of Microsoft; we make no warranty, implied or otherwise, regarding
these products' performance or reliability.
Modification Type: | Major | Last Reviewed: | 2/24/2004 |
---|