How to profile an OLE server or an OLE control in Visual C++ 6.0 (147393)



The information in this article applies to:

  • Microsoft Visual C++, 32-bit Enterprise Edition 6.0
  • Microsoft Visual C++, 32-bit Professional Edition 6.0
  • Microsoft Visual C++, 32-bit Learning Edition 6.0

This article was previously published under Q147393

SUMMARY

The Visual C++ Books Online section "Profiling Dynamic-Link Libraries" explains the steps involved in profiling dynamic-link libraries and profiling multiple .dll and .exe files.

Because an OLE server is basically an .exe or .dll file and an OLE control is a DLL even though it has an extension of .ocx, profiling them is similar to profiling an .exe or .dll file. When you profile an OLE server or OLE control, you follow the same steps and use the same commands that you would for an .exe or .dll file. The same profiling rules that apply to .exe and .dll files (such as the need to include debugging information and to supply a .map file) also apply to OLE servers and OLE controls.

MORE INFORMATION

The following four examples illustrate the steps required to profile an OLE full server, an OLE mini-server, an In-Process OLE Automation server, and an OLE control.

You may have to register the OLE mini-server, the in-process OLE automation server, or the OLE control explicitly. You can do one of the following to register them:
  • For a .dll file (and for an OLE control), run Regsvr32 from the command prompt. Alternatively, you can open the corresponding project in the Developer Studio, and then on the Tools menu, click Register Control.
  • For an .exe file, just run it once. You may not be able to run it or you may get a message saying "This server can only be run from a container application," but when you click OK, it will have been registered.
To run the profiler, you may need to copy the \Msdev\Bin\Profile.dll file to either the directory that contains the file you are profiling or to one of the system directories. This file is in the [DevStudio Path]\VC\Bin directory for version 5.0. This file is in the [Microsoft Visual Studio Path]\VC98\Bin directory for version 6.0.

Each step in the following examples is a command at the command prompt. Alternatively, you could create a batch file that contains these commands.

In the command line arguments for most profile commands, you should specify the file names without the extension. Look at the following examples to see when extensions should be included.

To profile an OLE full server or an OLE automation server:

PREP /OM /FT FullSrvr
PROFILE FullSrvr
PREP /M FullSrvr
PLIST FullSrvr > FullSrvr.txt


where FullSrvr.exe is the file corresponding to an OLE full server or OLE automation server.

To profile an OLE mini server:

COPY MiniSrvr.exe MiniSrvr.sav
PREP /OM /FT MiniSrvr
COPY MiniSrvr._xe MiniSrvr.exe
PROFILE /I MiniSrvr /O MiniSrvr Container
PREP /M MiniSrvr
PLIST MiniSrvr > MiniSrvr.txt
COPY MiniSrvr.sav MiniSrvr.exe


where MiniSrvr.exe is the file corresponding to an OLE mini server and Container.exe is a container application that runs the MiniSrvr.

To profile an In-Process OLE Automation Server (these steps are similar to those of OLE mini server except that you have a .dll extension instead of an .exe extension):

COPY InProc.dll InProc.sav
PREP /OM /FT InProc.dll
COPY InProc._ll InProc.dll
PROFILE /I InProc /O InProc Client
PREP /M InProc
PLIST InProc > InProc.txt
COPY InProc.sav InProc.dll


where InProc.dll is the file corresponding to an In-Process OLE Automation server and Client is an OLE Automation client application that drives the InProc.dll.

To profile an OLE control that has an .ocx extension (these steps are also similar except that you now have an .ocx extension):

COPY Control.ocx Control.sav
PREP /OM /FT Control.ocx
COPY Control._cx Control.ocx
PROFILE /I Control /O Control ControlContainer
PREP /M Control
PLIST Control > Control.txt
COPY Control.sav Control.ocx


where Control.ocx is the OLE control and ControlContainer is an OLE control container application.

For more information about how to profile more than one module, click the following article number to view the article in the Microsoft Knowledge Base:

179269 How to use Source Profiler to profile dynamic-link libraries

REFERENCES

Profiler Reference, Visual C++ User's Guide.

Advanced Profiling, Programming Techniques.

Both of these references are available in the online documentation that comes with Visual C++ versions 4.0 and later.