ACC2: GP Fault Using Print Definition from Query Builder (135489)
The information in this article applies to:
This article was previously published under Q135489
Moderate: Requires basic macro, coding, and interoperability skills.
SYMPTOMS
If you select Print Definition from the File menu while you are in the
Query Builder of either a report or form in Design view, a general
protection fault occurs. The general protection fault does not occur if you
select Print Definition while you are in the Query Builder of a query in
Design view.
RESOLUTION
Select Print Definition while you are in Design view of an existing query
and not from the RecordSource property's Query builder in a form or report.
If the RecordSource property for the form or report is an SQL statement,
invoke the Query Builder, and then select Save As from the File menu to
save the SQL statement as a query.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Access version
2.0. This problem no longer occurs in Microsoft Access version 7.0.
Modification Type: | Major | Last Reviewed: | 7/5/2002 |
---|
Keywords: | kbbug kberrmsg kbusage KB135489 |
---|
|