STOP: 0x0000000A with Future Domain SCSI Controller (117415)
The information in this article applies to:
- Microsoft Windows NT Server 3.1
- Microsoft Windows NT Workstation 3.1
- Microsoft Windows NT Advanced Server 3.1
This article was previously published under Q117415 SYMPTOMS
When you write data to a Micropolis 2217 or 2210 hard disk drive, using a
Future Domain TMC 1650 SCSI controller, the following STOP message may
appear:
STOP: 0x0000000A ( 0x00000000, 0x00000010, 0x00000001, 0x[address] )
IRQL_NOT_LESS_OR_EQUAL
The second parameter points to IRQL 16, the third parameter indicates a
write operation that failed, and the forth parameter points to HAL.DLL.
WORKAROUND
At this time, the only workaround is to use a SCSI controller card from a
different manufacturer or a different hard disk.
The products included here are manufactured by vendors independent of
Microsoft; we make no warranty, implied or otherwise, regarding these
products' performance or reliability.
Modification Type: | Major | Last Reviewed: | 11/20/2003 |
---|
Keywords: | kbother KB117415 |
---|
|