Error 58 with SMC Ethercard and ODI Drivers (111929)
The information in this article applies to:
- Microsoft Windows for Workgroups 3.11
This article was previously published under Q111929 SYMPTOMS
When you start Windows for Workgroups 3.11 on a Zenith computer using the
Zenith-provided ODI drivers for the bundled SMC Ethercard, you receive the
following error message:
Error 58: The network has responded incorrectly
CAUSE
The Zenith-provided version of the ODI driver is named ZECODI. If the SMC
Ethercard multiple link interface device (MLID) was installed after Windows
for Workgroups was set up, the Bindings= lines in the PROTOCOL.INI file are
written incorrectly.
RESOLUTION
To correct this problem, edit the PROTOCOL.INI file by replacing any
instances of SMC8000 with ZECODI in the Bindings= lines.
Zenith Technical Support recommends that customers use the drivers that
ship with their versions of the network card. Since there is no
OEMSETUP.INF file, users are directed to install the card as the SMC
Ethercard Plus. If the MLID is running before you set up Windows for
Workgroups, the Bindings= lines are written correctly. Windows for
Workgroups pulls the MLID name from LSL if the MLID is running.
Modification Type: | Major | Last Reviewed: | 9/29/1999 |
---|
Keywords: | KB111929 |
---|
|