TPW12A01INT TP Web Connector Gateway for ACMS Runtime 1.2A ECO Summary
TITLE: TPW12A01INT TP Web Connector Gateway for ACMS Runtime 1.2A ECO Summary
Copyright (c) Compaq Computer Corporation 1999. All rights reserved.
Modification Date: 16-DEC-1999
Modification Type: New kit
PRODUCT: Compaq TP Web Connector Gateway for ACMS Runtime 1.2A
OP/SYS: Windows NT Intel
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: TPW12A01INT
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 12068 Blocks (6.2 Mb)
Kit Applies To: Windows NT V4.0 - Intel
System/Cluster Reboot Necessary: No
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
ECO KIT SUMMARY:
An ECO kit exists for CompaqTP Web Connector Gateway for ACMS
Runtime V1.2A on Windows NT-Intel V4.0. This kit addresses the
following problems:
o If the environment variable stdl_log_file is set
to an invalid value, i.e. the directory path is invalid, the
application could hang when trying to do logging.
o On WindowsNT, if error logging is done to the
Event Log, the translation of the runtime error codes could
fail. This would occur only if a previous installation of
TP Web Connector was manually uninstalled, and the uninstall
utility was not used.
o Incorrect versions of three files that are part of the ADD
sample were included with the TP Web Connector V1.2A kit.
The files are: add_local_isapi.c, add_acmsxp_isapi.c,
and add_acms_isapi.c. These versions included html tags,
which will prohibit the files from compiling. The correct
versions of these files are included in this ECO.
o The date manipulation routine was causing memory corruption
under certain circumstances. This problem has been fixed.
INSTALLATION NOTES:
Installation of this kit requires that TP Desktop Connector
Version 3.1A be present on the system prior to installing the ECO.
This installation does not ask for any product install keys.
Copy the following product/platform specific executable to a clean
folder and run it.
e.g. Intel compatible PC running Windows NT
>cd c:\clean-folder
>tpw12a01int.exe
After running the executable, go to the intel32 directory
and execute Setup.exe.
Restrictions and Requirements:
* Installation of ECO kit will update all TPware Product Suite
products (Application Optimizer for Windows NT, Portable TP for
Windows NT, TP Desktop Connector & TP Web Connector) currently
installed on the system. It is not necessary to perform a
separate installation for each TPware product installed on the
system.
* After installing the ECO, if your application uses the Microsoft RPC
(msrpc) adapter, the DCE (dce) adapter, or the ACMS Gateway (acmsda)
adapter, you must recompile your task group specification (STDL file)
and relink with your client.
* Please refer to Release Notes for installation restrictions
and guidelines.
All trademarks are the property of their respective owners.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
tpw12a01int.README
tpw12a01int.CHKSUM
tpw12a01int.CVRLET_TXT
tpw12a01int.exe
tpw12a01int.CVRLET_TXT
|