MS-WNT MRU_V141_INTEL Media Robot Utility for Windows NT Intel ECO Summary
TITLE: MS-WNT MRU_V141_INTEL Media Robot Utility for Windows NT Intel ECO Summary
Copyright (c) Compaq Computer Corporation 2000. All rights reserved.
Modification Date: 24-MAY-2000
Modification Type: New Kit
PRODUCT: Media Robot Utility for WNT Intel
OP/SYS: Microsoft Windows NT
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: MRU_V141_INTEL
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 6418 Blocks
Kit Applies To: Media Robot Utility V1.4
Microsoft Windows NT V4.0
System/Cluster Reboot Necessary: Information Not Available
Rolling Re-boot Supported: Information Not Available
Installation Rating: INSTALL_UNKNOWN
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for the Media Robot Utility on Microsoft Windows
NT V4.0 Intel. This kit addresses the following problems:
o In case of an ESL 9000(multitower) with 3 units of
ESL9326D, 'read element status'(RES) for SLOTS could not be
issued. This problem was noticed with respect to the
"robot find cartridge" command.
The problem was analysed to occur due to a VMS imposed restriction
that RES could return data of length 64K or less only.
In case of the ESL9326D the returned data length would be
978 X 88 = 86064.
The fix for this problem involved capturing return values
larger than the allowed length, in parts and thus
fitting the RES of the SLOTS within the permitted length.
o In case of a multitude of PORTS in use, time taken for
GUI and CLI commands to execute used to be high because
of too many RES in use. This problem has been fixed in
this ECO by the use of a single RES instead of many.
o The MRU-UNIX command "robot show drive", showed drives of
only one unit, as "Available". This problem has been
fixed in this ECO, all drives will now be "available".
o New Features:
-------------
New functionality comprises, additional support for the following:
a) TSL10000
b) SSL2000
c) Tru64 UNIX V4.0G
d) Tru64 Unix V5.0 and 5.0A (with restrictions. For details
refer refer to Chapter 3 of COMPAQ Media Robot Utility - Guide
to Installation, Connectivity, and Operation.)
INSTALLATION NOTES:
The images in this kit will not take effect until the system is
rebooted. If there are other nodes in the VMScluster, they must
also be rebooted in order to make use of the new image(s).