SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
Compaq Pascal PASCAL_E1058 V5.8 Compilers Alpha ECO Summary

TITLE: Compaq Pascal PASCAL_E1058 V5.8 Compilers Alpha ECO Summary Modification Date: 24-JAN-2001 Modification Type: New Kit Copyright (c) Compaq Computer Corporation 2000. All rights reserved. PRODUCT: Compaq Pascal for OpenVMS Alpha Systems OP/SYS: OpenVMS Alpha COMPONENT: SYS$SYSTEM:PASCAL.EXE SOURCE: Compaq Computer Corporation ECO INFORMATION: ECO Kit Name: PASCAL_E1058 ECO Kits Superseded by This ECO Kit: None ECO Kit Approximate Size: 22,446 Blocks Kit Applies To: OpenVMS Alpha V6.1 and higher Compaq Pascal for OpenVMS Alpha V5.8 System/Cluster Reboot Necessary: No Rolling Re-boot Supported: No Installation Rating: INSTALL_UNKNOWN Kit Dependencies: The following remedial kit(s) must be installed BEFORE installation of this kit: None In order to receive all the corrections listed in this kit, the following remedial kits should also be installed: None ECO KIT SUMMARY: An ECO kit exists for Pascal V5.8 Compilers on OpenVMS Alpha V6.1 and higher.This kit addresses the following problems: Problems Addressed In PASCAL_E1058: o Compaq Pascal V5.8 introduced additional support for debugging of schema types. When processing a routine that has a procedure parameter which itself has a schematic parameter, the compiler will generate incorrect code. The incorrect code will fail at run-time. For example, PROGRAM TEST (OUTPUT); PROCEDURE MAIN; VAR ID: INTEGER := 100; PROCEDURE INVOKE_PRINT (PROCEDURE PRINT(MESSAGE: STRING)); BEGIN PRINT('this is a bug'); END; PROCEDURE PRINT_MESSAGE (MESSAGE: STRING); BEGIN WRITE('id=', id:1, ' '); IF ID <> 100 THEN WRITELN(MESSAGE); WRITELN; END; BEGIN INVOKE_PRINT(PRINT_MESSAGE) END; BEGIN MAIN; END. will get different results compiled /DEBUG vs compiled without /DEBUG. This problem has been corrected. o Compaq Pascal V5.8 introduced additional support for debugging of schema types. However, the algorithm used could lead to very long compilation times when using /DEBUG. One case reported went from 1:12 to 20:00 minutes. The slowdown can occur even if the program does not use schema types. The algorithm has been modified to reduce the overhead for /DEBUG to approximately 6% (which is similar to the overhead for /DEBUG with the V5.7 compiler). o Compaq Pascal V5.7-84 included a fix for typecasting arrays or records to smaller types and getting the size of these typecasted variables correct. However, this change was incorrect when applied to ordinal types like subranges. For example, the following program produces incorrect results: PROGRAM CAST_VARIABLE(OUTPUT); TYPE SUBRANGE = 0..999999999; SUBRANGE_WITH_SIZE = [BIT(32)] SUBRANGE; VAR NUMBER : SUBRANGE; II : INTEGER32; BEGIN NUMBER := 80; II := -1; II :: SUBRANGE := NUMBER; WRITELN(BIN(II), " Binary data after cast"); WRITELN(BIN(NUMBER)," Expected binary data"); II := -1; II :: SUBRANGE_WITH_SIZE := NUMBER; WRITELN(BIN(II), " Binary data after cast"); WRITELN(BIN(NUMBER)," Expected binary data"); END. This compiler has been fixed to restore the correct behavior for the above example and to fix the original problem also. INSTALLATION NOTES: The kit must be unpacked with UNZIP. Inside the PASCAL_E1058 ZIP file are 4 BACKUP savesets that comprise the Compaq Pascal kit. Once unpacked, install this kit with the VMSINSTAL utility by logging into the SYSTEM account, and typing the following at the DCL prompt: @SYS$UPDATE:VMSINSTAL PASCAL_E1058 [location of the savesets] A system reboot is not necessary. However, if you are installing this ECO in a VMScluster environment, you should invoke the SYS$STARTUP:PASCAL$STARTUP.COM command file on the other nodes in the the cluster so the new compiler image will be properly installed. All trademarks are the property of their respective owners.



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

pascal_e1058.README
pascal_e1058.CHKSUM
pascal_e1058.CVRLET_TXT
pascal_e1058.zip
pascal_e1058.CVRLET_TXT

privacy and legal statement