SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
SNA_PU5-UNIX SNAPU5_UE02021 SNA Gateway V2.1 Tru64 UNIX ECO Summary

TITLE: SNA_PU5-UNIX SNAPU5_UE02021 SNA Gateway V2.1 Tru64 UNIX ECO Summary Copyright (c) Compaq Computer Corporation 1998, 2000. All rights reserved. Modification Date: 10-FEB-2000 Modification Type: Updated Kit Supersedes SNAPU5_UE01021 PRODUCT: DECnet/SNA Domain Gateway-CT V2.1 DECnet/SNA Domain Gateway-ST V2.1 OP/SYS: DEC OSF/1 DIGITAL UNIX Tru64 UNIX SOURCE: Compaq Computer Corporation ECO INFORMATION: ECO Kit Name: SNAPU5_UE02021 ECO Kits Superseded by This ECO Kit: SNAPU5_UE01021 ECO Kit Approximate Size: 9340 Blocks SNAPU5_UE02021.TAR - 9340 Blocks Kit Applies To: DEC OSF/1 V2.1 through Tru64 UNIX V5.0 System/Cluster Reboot Necessary: No Rolling Re-boot Supported: Information Not Available Installation Rating: INSTALL_UNKNOWN Kit Dependencies: The following remedial kit(s) must be installed BEFORE installation of this kit: None In order to receive all the corrections listed in this kit, the following remedial kits should also be installed: None ECO KIT SUMMARY: An ECO kit exists for DEC SNA Domain Gateway V2.1 on DEC OSF/1 V2.1 through Tru64 UNIX V5.0. This kit addresses the following problems: Problems addressed in SNAPU5_UE02021: The DECnet/SNA Domain Gateway Release Notes contain a complete explanation of the fixes contained in this ECO. Listed below is a brief description of them. o If an old PU/Sess Address name style was used, ie, SNA-0.5, the error "combination of connect flags is invalid" would be returned. The software was modified to interpret an old style name under a passive connect as valid under GAP V3.0. o A GAP V3 connection to the gateway was rejected if an Access Name had the trailing spaces. This problem has been fixed in this release, we now trim the trailing spaces off. o Fixed a problem exhibited by PrE in which a bind response was lost and the session and link between PrE and the Domain Gateway hangs. The cause was the receipt of a Bind over a virtual route that was in the process of an orderly deac- tivation sequence. The remote side _RSP to the request as it had already initiated a new session. The Domain Gateway discards the bind response in Subarea Path Control due to an erroneous check to determine if the VR was active. o The SNAPU5 V2.1 is now supported on Tru64 UNIX V5.0 systems (formerly known as Digital UNIX). Problems addressed in SNAPU5_UE01021: The DECnet/SNA Domain Gateway Release Notes contain a complete explanation of the fixes contained in this ECO. Listed below is a brief description them. o The script compiler errors if lu names have an "@" without double quotes. The configurator was fixed to place quotes around lu names. o Fixed a crash where the next_lpd = 0 and sapc$vr_neg_rsp was called by resetting the in_biu bit and setting l_lrb_size to 0 when we finish a recombination of a PIU into a BIU. The crash was caused by the in_biu flag being on and the LRB empty. o Release Linkdel LPD if you call channel_disconnect. Once channel_disconnect is called, we have to get rid of the Linkdel LPD, else we try to send it later in sock_terminate when TCP tells us to go away. o Uninitalized queues in up cdb would cause a bugcheck if not 0 at channel deletion time. The crash would show UPCDB$A_ PASSIVE_FL 0000FFFF. o Fixed an access violation adding/removing TCP port attribute blocks from the tree structure. A logic problem in LUMGR set a pointer to 0 of a deallocated structure that was re- allocated in TCP. Cleaned up TCP handling of port attribute blocks for an additional bug removing an element that wasn't added to the tree. o Removed bugcheck in the case where a CDTERM is received for a session initiated by a 3rd party (Init-other-cd) , which did not request term. Notification. This occurred when the session termination indicated that it was via Netmgr. o Fixed an access violation caused by storing reference to SSCP-SSCP Notifies on the CDRM response queue. There are no responses to correlate with, thus the entry remains on the queue. A subsequent RU reusing that SNF (wrap) that indeed gets a response causes the wrong entry to be dequeued. No longer store Notifies. o The configuration utility was unable to handle LU names that contained "@" or "#" characters. This fix puts quotes around the LU names where necessary in the generated NCL script. A side affect of this fix is that wildcarded LU name specifi- cations in the LU list for an access name will be expanded to the exact list of LUs matching the wildcard if the spec- ified wildcarded LU contains "@" or "#" characters. This is because NCL treats quoted wildcard characters literally. INSTALLATION NOTES: Note that this is a complete kit. The current version of the Domain Gateway must be deleted before installing this ECO. Removing the subsets will not remove your configuration files. However, it is suggested you create copies to prevent accidental removal. Save copies of your current (cmip,ncl,icu) configuration files before installing this ECO kit to another directory. The ECO kit is distributed as a tar file containing the kit which can be installed using the setld command. The tar file should be unpacked to a suitable directory and then the setld command issued specifying that directory as the source of the kit. For example, if the tar file containing the kit has been copied to /usr/tmp/snapu5.tar: # mkdir /usr/tmp/snapu5 # cd /usr/tmp/snapu5 # tar xf /usr/tmp/snapu5.tar # setld -l . If the kit is delivered on tap11 then the commands would be: # mkdir /usr/tmp/snapu5 # cd /usr/tmp/snapu5 # tar x # setld -l . Implementation -------------- The Domain Gateway must be reloaded for fixes to be made operational. The gateway need not be reconfigured.



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

snapu5_ue02021.README
snapu5_ue02021.CHKSUM
snapu5_ue02021.CVRLET_TXT
snapu5_ue02021.tar
snapu5_ue02021.CVRLET_TXT

privacy and legal statement