The NetraDaemonStatus parameter reports the status of the watchdog process
which should be running on the Netra system. The parameter information is
presented on a graph where "1" represents "off", "2" represents "on" and "0"
represents "unsupported".
The tsdog process monitored is only present in TSalarms and version 1 of the
CONFIGURATION
Lomlite software. The watchdog is implemented within the lom driver for version
2 of the Lomlite software and hence the parameter is marked as unsupported.
NetraDaemonStatus Application: ESP_NETRA_DOG
Parameter type = CONSUMER
Active = True
Poll time = <empty>
Title = Watchdog Daemon Status 1=OFF 2=ON (0=unsupported)
Units = Status
Graph output type = OUTPUT_GRAPH
Border Definition
Active = False
Alarm Range definition = 0 - 0
Between these values, the state = OK
When does the alarm trigger = ALARM_INSTANT
After how many poll is the alarm shown on the console = 0
Alarm 1 Definition
Active = True
Alarm Range definition = 1 - 1
Between these values, the state = WARN
When does the alarm trigger = ALARM_INSTANT
After how many poll is the alarm shown on the console = 0
Alarm 2 Definition
Active = False
Alarm Range definition = 2 - 2
Between these values, the state = OK
When does the alarm trigger = ALARM_INSTANT
After how many poll is the alarm shown on the console = 0