Patch-ID# 106445-01
Keywords: SNC script appends server name save word invalid path 
Synopsis: SNC 3.1.1 _x86: Script Interpreter appends '~1' to server name 
Date: Jun/15/98

Solaris Release:  

SunOS Release: 

Unbundled Product: Solstice Network Client (SNC) 

Unbundled Release: 3.1.1

Relevant Architectures: i386

BugId's fixed with this patch: 4135723

Changes incorporated in this version:  4135723

Patches accumulated and obsoleted by this patch:  

Patches which conflict with this patch:  

Patches required with this patch: 

Obsoleted by: 

Files included with this patch: 
 readme.txt
 sunwnpnt.dll
 sunwrun.exe

Problem Description:
The customer has created an ntlogon.snc script that he has put in /opt/MSPolicy 
on his pcnfsd server which is TIMELORD
The script contains the following:
MOUNT DRIVE timelord:/rjp F:
PAUSE 5
EXIT
When he logs in to his NT machine the script runs and connects the F: drive, the 
problem is when the drive is connected it displays the following:
rjp on 'timelord~1'(F:)
In the registry there are entries for both timelord and timelord~1.  
This problem occurs only if the ntlogon.snc is attempting to mount a file system 
from the pcnfsd server that the nt machine has authenticated from. 
When the customer attempts to save a file from an application such as word to  the mounted drive he gets the following error:

This is not a valid filename.
Try one or more of the following:

* Check the path to make sure it was typed correctly.
* Select a file from the lis of files and folders.
(\\timelord~1\rjp\test.doc) 


Patch Installation Instructions:

 This patch is for Windows NT ONLY.
 
 This patch is packaged as a self-extracting compressed file (10644501.exe).  
 It must be installed from Windows NT.  The setup program backs up the original 
 file(s).  It then installs the new file(s) and a patch uninstall utility. 
 To install, download 10644501.exe to a temporary directory on the PC.  
 
 In Windows, select "Run" from the "Start" menu.  Enter the path and 
 patch filename (Example: c:\temp\10644501) then select "OK".  
 The patch will uncompress and start the setup program automatically.  
 Follow the setup program prompts to complete the patch installation.  
 Restart Windows.

 NOTE:
  After restarting windows -- remember to copy sunwrun.exe 
  from \program files\solstice\bin
  to /opt/MSPolicy directory on your PCNFSD server.

Patch Removal Instructions:

 In Windows NT, click "Start".  Then select "Programs", "Patch 10644501"
 and click on "uninstallSHIELD".  

 WARNING - The patch uninstall program restarts Windows at the end
           of the uninstall process.
 

Installation Notes:

 All drive letter and directory name references are Solstice Network Client
 defaults. If you have installed Solstice Network Client or the patch file on 
 a different drive, or in a different directory, substitute your 
 drive and directory names in the example commands above.
