PLY_NETVIEW-OSF PNVECO01412 POLYCENTER Manager NetView V4.1B ECO Summary
Copyright (c) Digital Equipment Corporation 1996. All rights reserved.
PRODUCT: POLYCENTER Manager on Netview for Digital UNIX
OP/SYS: Digital UNIX[R]
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: PNVECO01412
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 17240 Blocks
8826880 Bytes
Kit Applies To: POLYCENTER Manager on Netview for Digital UNIX V4.1B
Digital UNIX V3.2 through V4.0
System/Cluster Reboot Necessary: No
ECO KIT SUMMARY:
An ECO kit exists for POLYCENTER Manager on NetView for Digital UNIX
V4.1B on Digital UNIX V3.2 through V4.0. This kit addresses the
following problems:
o c_arf2srf command would core
The c_arf2srf command would core dump whenever used.
o Events window would core when clearing selected events from a
workspace
The Events window (nvevents) would core when the menu item
"Edit->Clear Selected->From This Workspace" was selected.
o nvsecd would core when "Group list" popup was selected from nvauth
The nvsecd daemon would core when the "Group list" popup was
selected from the nvauth application
o Acknowledge propagation not working for open topology
When you acknowledged one interface for a node, the node would turn
green (even though there were other red interfaces for the node
which had not been acknowledged).
o EUI would core when doing "refresh" after double-clicking on
childless icon
The EUI would core when doing a "File->Refresh Map" on a read-only
map after double-clicking on an icon with no children.
o Automatic action for traps would sometimes not work
Under certain circumstances, an automatic action for a trap would
not be invoked and the error message which was displayed showed
garbage characters at the end of the action command.
o In the Events Window, "Suppress Traps From Unmanaged Nodes" would
not work
In the Events Window, "Options->Suppress Traps From Unmanaged Nodes"
would not work correctly, traps from unmanaged nodes were still
appearing in the Events window.
o Trap configuration updates not occurring immediately
After modifying a trap using the "Options->Event Configuration:
Trap Customization: SNMP..." window, the modification would not
take effect until the daemons were stopped and restarted.
NOTE: This problem only occurred on Digital UNIX V4.0.
o Cores fixed in nvserverd and nvlockd daemons
Under certain circumstances, the nvserverd and nvlockd daemons
would core.
INSTALLATION NOTES:
The installation will only succeed if V4.1B of POLYCENTER Manager on
Netview is already installed. To verify that POLYCENTER Manager on
NetView V4.1B is installed type:
# setld -i | grep PNV | grep installed
To un-tar this ECO kit, type the following commands:
#cd [directory where you want to store the kit]
#tar xvf pnveco01412.tar
Install this kit with the setld utility by logging into the
root account, and typing the following at the system prompt:
#setld -l [directory in which you un-tared the kit]
The ECO kit checks to ensure that a valid license is installed before
proceeding. If one is not found, the installation aborts.
[R] UNIX is a registered trademark in the United States and other
countries licensed exclusively through X/Open Company Limited.
Files on this server are as follows:
pnveco01412.README
pnveco01412.CHKSUM
pnveco01412.CVRLET_TXT
pnveco01412.tar
|